ABSTRACT
Objectives To compare the performance of 3D T1 turbo spin echo (3DT1TSE) and 3D T1 turbo field echo (3DT1TFE) MRI in detecting gadolinium-enhancing lesions in multiple sclerosis (MS).
Methods We retrospectively analyzed 255 3T MRIs from MS patients, each including post-contrast 3DT1TSE and 3DT1TFE sequences. Two blinded readers independently assessed enhancing lesions per sequence. A consensus review, incorporating longitudinal imaging and additional sequences, served as the reference standard.
Results The consensus identified 70 enhancing lesions in 31 patients. All 70 were visible on 3DT1TSE, while 64 (91%) were detectable on 3DT1TFE. Reader sensitivity was higher for 3DT1TSE (84% and 90%) than 3DT1TFE (45% and 40%) (p < 0.01). Inter-reader agreement was excellent for 3DT1TSE (ICC = 0.90) and moderate for 3DT1TFE (ICC = 0.69). Although false positives were more common with 3DT1TSE, they were readily excluded during consensus reading. In six patients, enhancing lesions were detected only on 3DT1TSE, with treatment escalation in two.
Conclusion 3DT1TSE outperformed 3DT1TFE in sensitivity and reader agreement for enhancing lesion detection in MS. Incorporating 3DT1TSE into standard MRI protocols may improve disease activity assessment and clinical decision-making.
Competing Interest Statement
The institution where Sergio Martinez-Yelamos and Antonio Martinez-Yelamos work (Hospital Universitari de Bellvitge / Institut d'Investigacio Biomedica de Bellvitge) has received, in the last 3 years and exclusively to support the research of the Unit, advisory fees, collaboration funds, donations, or consultancy payments from the following companies: Almirall, Bayer, Biogen, Bristol Myers Squibb, Celgene, Genzyme, Horizon/Amgen, Janssen, Kern Pharma, Lilly, Merck, Neuraxpharm, Novartis, Roche, Sandoz, and Sanofi.
Funding Statement
This study received funding from the Institut de Diagnostic per la Imatge (IDI) under the reference PREDOC IDI 22, dated October 3, 2022. The funding was specifically allocated for manuscript proofreading.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
This study was approved by the Research Ethics Committee of Bellvitge University Hospital (reference PR192/24). The requirement for informed consent was waived due to the retrospective observational nature of the study and compliance with national and European Union regulations. All data were anonymized prior to analysis.
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.
Yes
Data Availability
The data that support the findings of this study are available from the corresponding author upon reasonable request.
Abbreviations
- MS
- multiple sclerosis
- 3DT1TSE
- 3D T1-weighted turbo spin echo
- 3DT1TFE
- 3D T1-weighted turbo field echo
- GBCA
- gadolinium-based contrast agent
- FLAIR
- fluid-attenuated inversion recovery
- EDSS
- expanded disability status scale
- DMT
- disease-modifying treatment
- ICC
- intra-class correlation coefficient
- PRL
- paramagnetic rim lesion
- SWIp
- susceptibility-weighted imaging with phase enhancement
- SNR
- signal to noise ratio
- CNR
- contrast to noise ratio





