Abstract
To quantify the effect of negative pressure applied to the anterior surface of the eye on absolute IOP.
Subjects Participants, and/or Controls. Three eyes from three research-consented brain-dead organ donors.
Methods Air-tight goggles connected to a negative pressure (NP) pump (Mercury Multi-pressure Dial (MPD); Equinox Ophthalmic, Inc., CA) were tested on three research consented brain-dead organ donors. The MPD was set to generate a vacuum of -20mmHg. A baseline IOP of 10, 20, and 30mmHg was sequentially set by adjusting the height of a balanced salt solution bottle connected to the cornea through a 20G needle. IOP was manually annotated at time = 0s, right before turning on the vacuum pump; after a few seconds with the vacuum pump ON; at 60s; at 120s, right before turning the pump OFF; at 240s with the pump OFF (recovery). Three repetitions per each test at varying baseline IOP were taken for a total of nine series of measures per eye.
Main Outcome Measures IOP change with exposure to NP.
Results Eye1 and 3 showed an immediate reduction in IOP at all baselines immediately following activation of the MPD NP pump; Eye2 showed an opposite response to NP. Eye1 and 3 showed a reduction in IOP at all baselines with NP pump ON for 60s and 120s, while Eye 2 showed a consistent increase in IOP. After 120s from turning NP OFF (time=240s), IOP partially recovered to its baseline in all eyes.
Conclusions This study is the first to evaluate changes in manometrically-measured intracameral IOP due to NP applied to the ocular surface in living conditions. The inconsistent response of IOP following exposure to negative pressure warrants further investigations on the mechanism underlaying IOP lowering by NP.
Competing Interest Statement
Heidelberg Engineering, GmbH: Hardware support Topcon Medical Systems, Inc.: Financial and hardware support Equinox Ophthalmic, Inc.: Licensing fees for part of the published dataset Patent: Colocalized detection of retinal perfusion and optic nerve head deformations, WO2019178185A1 Patent: Retinal vascular stress test for diagnosis of vision-impairing diseases, WO2021158903A1
Funding Statement
National Eye Institute, R01 EY028284 Research to Prevent Blindness (unrestricted grant) EyeSight Foundation of Alabama (unrestricted grant)
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
All components of this study adhered to the Declaration of Helsinki and were approved by the UAB Institutional Review Board and Legacy of Hope Research Review Board.
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Footnotes
The revised version slightly modifies Figure 2 and Table 2 for more immediate interpretation. Two labels in Tables 3 and 4 are then edited to align them with the edits of Fig. 2 and Table2. Line spacing in the Discussion was also discordant with the other sections. All terms are now capitalized in Abbreviations.
Data Availability
All data produced in the present study are available upon reasonable request to the authors
Abbreviations
- (IOP)
- Intraocular Pressure;
- (MPD)
- Multi-Pressure Dial;
- (BDOD)
- Brain-Dead Organ Donors;
- (BSS)
- Balanced Salt Solution;
- (OCT)
- Optical Coherence Tomography;
- (OCTA)
- Optical Coherence Tomography Angiography;
- (ONH)
- Optic Nerve Head;
- (CSFP)
- Cerebrospinal Fluid Pressure;
- (RNFL)
- Retinal Nerve Fiber Layer;
- (PCD)
- Perfused Capillary Density;