Abstract
Background Visualization of aqueous humor flow in the human eye is difficult because gadolinium, a magnetic resonance imaging (MRI) contrast agent, does not readily cross the blood-retinal and blood-aqueous barriers of capillaries that supply water to the eye. The proton (1H) of oxygen-17 water (H217O) has a very short transverse relaxation time (T2), and the T2-weighted (T2W) 1H-MRI signal intensity of a region with H217O is lower than that with only H2 16O.
Purpose To observe the distribution of H217O in the human eye, and the flow into and out of the anterior chamber of H217O, using dynamic T2W 1H-MRI.
Materials and Methods Seven ophthalmologically normal adult volunteers under 40 years old participated in this study. During dynamic imaging, the subject self-administered 10 mol% H217O saline (0.92–1.37 mL) to their right eye for 1 min. Time-series images were created by subtracting the image before the eye drops from each of the images obtained after the eye drops. The “normalized signal intensity of the right anterior chamber” (rAC) in each image was obtained by dividing the signal intensity of the right anterior chamber region-of-interest by that of the left. Changes in transverse relaxation rate and H217O concentration (PO17) were calculated from the rAC. The inflow and outflow constants of H217O in the right anterior chamber were also determined.
Results Decreased signal intensity after the H217O eye drops was observed in the anterior and posterior chambers, but not in the vitreous body. The rAC signal intensity decreased after the eye drops, and then recovered to close to rAC(0) at 40 min. The inflow and outflow constants were 0.53 ± 0.19 and 0.055 ± 0.019 min-1, respectively, and the peak value of PO17 was 0.19 ± 0.04% (mean ± SD).
Conclusion H217O saline eye drops distributed in the human anterior and posterior chambers. Further, the eye drops smoothly flowed into, and slowly out of, the anterior chamber.
Summary O-17 water dropped into human eyes as a T2-weighted MRI contrast agent was distributed in the anterior and posterior chambers, with smooth flow into, and slow outflow from, the anterior chamber.
Key findings In seven healthy volunteers, dynamic T2-weighted 1H-MRI showed that the signal intensity in the anterior chamber decreased smoothly after H217O eye drops and then slowly recovered, reaching a value close to that observed before the eye drops, after 40 minutes, with inflow and outflow constants of H217O of 0.53 ± 0.19 min-1 and 0.055 ± 0.019 min-1, respectively. The signal changes were limited to the anterior and posterior chambers and were not observed in the vitreous body.
Competing Interest Statement
The authors have declared no competing interest.
Clinical Trial
jRCTs031210082
Funding Statement
This work was supported by a Grant-in-Aid (Public/Private R&D Investment Strategic Expansion PrograM: PRISM) from the Cabinet Office, Japan.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
This study was approved by the Ethics Committee of the National Institutes for Quantum Science and Technology (approval number CRB3180004).
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
All data in the present study are available from the corresponding author upon reasonable request.
Abbreviations
- dT2W_MRI
- dynamic T2W 1H-MRI
- ΔR2, H
- transverse relaxation rate change of the H2O proton
- H217O
- oxygen-17 water
- IQR
- interquartile range
- PO17
- the molar fraction of H217O
- R2, H
- transverse relaxation rate of the H2O proton
- transverse relaxation rate of the H216O proton
- transverse relaxation rate of the H217O proton
- rAC
- normalized signal intensity of the right anterior chamber
- ROI
- region of interest