Skip to main content
medRxiv
  • Home
  • About
  • Submit
  • ALERTS / RSS
Advanced Search

Novel Application of a Force Sensor during Sit-to-Stands to Measure Dynamic Cerebral Autoregulation Onset

Alicen A. Whitaker, View ORCID ProfileEric D. Vidoni, Stacey E. Aaron, Adam G. Rouse, Sandra A. Billinger
doi: https://doi.org/10.1101/2022.01.14.22269108
Alicen A. Whitaker
1Department of Physical Therapy, Rehabilitation Science, and Athletic Training, University of Kansas Medical Center, Kansas City, KS
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Eric D. Vidoni
2University of Kansas Alzheimer’s Disease Research Center, Fairway, KS
3Department of Neurology, University of Kansas Medical Center, Kansas City, KS
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Eric D. Vidoni
Stacey E. Aaron
1Department of Physical Therapy, Rehabilitation Science, and Athletic Training, University of Kansas Medical Center, Kansas City, KS
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Adam G. Rouse
4Department of Molecular and Integrative Physiology, University of Kansas Medical Center, Kansas City, KS
5Department of Neurosurgery, University of Kansas Medical Center, Kansas City, KS
6Department of Electrical Engineering and Computer Science, University of Kansas, Lawrence, KS
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sandra A. Billinger
1Department of Physical Therapy, Rehabilitation Science, and Athletic Training, University of Kansas Medical Center, Kansas City, KS
2University of Kansas Alzheimer’s Disease Research Center, Fairway, KS
3Department of Neurology, University of Kansas Medical Center, Kansas City, KS
4Department of Molecular and Integrative Physiology, University of Kansas Medical Center, Kansas City, KS
7Department of Physical Medicine and Rehabilitation, University of Kansas Medical Center, Kansas City, KS
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: sbillinger@kumc.edu
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Supplementary material
  • Data/Code
  • Preview PDF
Loading

Abstract

Purpose Current sit-to-stand methods measuring dynamic cerebral autoregulation (dCA) do not capture the precise onset of the time delay (TD) response. Reduced sit-to-stand reactions in older adults and individuals post-stroke could inadvertently introduce variability, error, and imprecise timing. We applied a force sensor during a sit-to-stand task to more accurately determine how TD before dCA onset may be altered.

Methods Middle cerebral artery blood velocity (MCAv) and mean arterial pressure (MAP) were measured during two sit-to-stands separated by 15 minutes. Recordings started with participants sitting on a force-sensitive resistor for 60 seconds, then asked to stand for two minutes. Upon standing, the force sensor voltage immediately dropped and marked the exact moment of arise- and-off (AO). Time from AO until an increase in cerebrovascular conductance (CVC = MCAv/MAP) was calculated as TD.

Results We tested the sensor in 4 healthy young adults, 2 older adults, and 2 individuals post-stroke. Healthy young adults stood quickly and the force sensor detected a small change in TD compared to classically estimated AO, from verbal command to stand. When compared to the estimated AO, older adults had a delayed measured AO and TD decreased up to ~53% while individuals post-stroke had an early AO and TD increased up to ~14%.

Conclusion The transition reaction speed during the sit to stand has the potential to influence dCA metrics. As observed in the older adults and participants with stroke, this response may drastically vary and influence TD.

New & Noteworthy We developed a force sensor and are the first to apply it during sit-to-stands measuring the dynamic cerebral autoregulation (dCA) response. Current methodologies estimate the transition reaction speed of the sit-to-stand, which influences the dCA metrics. Compared to estimating the kinetic moment of arise-and-off (AO), our force sensor can detect early or delayed AO in individuals who may present with lower extremity weakness such as older adults and clinical populations such as stroke.

Competing Interest Statement

The authors have declared no competing interest.

Funding Statement

AW was supported by the Eunice Kennedy Shriver National Institute of Child Health & Human Development of the National Institutes of Health (T32HD057850). SA was supported by a CTSA grant from NCATS awarded to the University of Kansas for Frontiers: University of Kansas Clinical and Translational Science Institute (TL1TR002368). SB and EV were supported in part by the National Institute on Aging for the KU Alzheimers Disease Research Center (P30AG072973). The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health. REDCap at University of Kansas Medical Center is supported by Clinical and Translational Science Awards (CTSA) Award # ULTR000001 from National Center for Research Resources (NCRR). The Georgia Holland Research in Exercise and Cardiovascular Health (REACH) laboratory space was supported by the Georgia Holland Endowment Fund.

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

The study was approved by the University of Kansas Medical Center Institutional Review Board Human Subjects Committee

I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.

Yes

Data Availability

All data produced in the present study are available upon reasonable request to the authors.

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. It is made available under a CC-BY-NC 4.0 International license.
Back to top
PreviousNext
Posted January 14, 2022.
Download PDF

Supplementary Material

Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Novel Application of a Force Sensor during Sit-to-Stands to Measure Dynamic Cerebral Autoregulation Onset
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Novel Application of a Force Sensor during Sit-to-Stands to Measure Dynamic Cerebral Autoregulation Onset
Alicen A. Whitaker, Eric D. Vidoni, Stacey E. Aaron, Adam G. Rouse, Sandra A. Billinger
medRxiv 2022.01.14.22269108; doi: https://doi.org/10.1101/2022.01.14.22269108
Reddit logo Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
Novel Application of a Force Sensor during Sit-to-Stands to Measure Dynamic Cerebral Autoregulation Onset
Alicen A. Whitaker, Eric D. Vidoni, Stacey E. Aaron, Adam G. Rouse, Sandra A. Billinger
medRxiv 2022.01.14.22269108; doi: https://doi.org/10.1101/2022.01.14.22269108

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Rehabilitation Medicine and Physical Therapy
Subject Areas
All Articles
  • Addiction Medicine (230)
  • Allergy and Immunology (507)
  • Anesthesia (111)
  • Cardiovascular Medicine (1264)
  • Dentistry and Oral Medicine (207)
  • Dermatology (148)
  • Emergency Medicine (283)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (538)
  • Epidemiology (10056)
  • Forensic Medicine (5)
  • Gastroenterology (502)
  • Genetic and Genomic Medicine (2486)
  • Geriatric Medicine (240)
  • Health Economics (482)
  • Health Informatics (1653)
  • Health Policy (757)
  • Health Systems and Quality Improvement (638)
  • Hematology (250)
  • HIV/AIDS (538)
  • Infectious Diseases (except HIV/AIDS) (11896)
  • Intensive Care and Critical Care Medicine (627)
  • Medical Education (255)
  • Medical Ethics (75)
  • Nephrology (269)
  • Neurology (2304)
  • Nursing (140)
  • Nutrition (354)
  • Obstetrics and Gynecology (458)
  • Occupational and Environmental Health (537)
  • Oncology (1259)
  • Ophthalmology (377)
  • Orthopedics (134)
  • Otolaryngology (226)
  • Pain Medicine (158)
  • Palliative Medicine (50)
  • Pathology (326)
  • Pediatrics (737)
  • Pharmacology and Therapeutics (315)
  • Primary Care Research (282)
  • Psychiatry and Clinical Psychology (2295)
  • Public and Global Health (4850)
  • Radiology and Imaging (846)
  • Rehabilitation Medicine and Physical Therapy (493)
  • Respiratory Medicine (657)
  • Rheumatology (289)
  • Sexual and Reproductive Health (241)
  • Sports Medicine (228)
  • Surgery (273)
  • Toxicology (44)
  • Transplantation (131)
  • Urology (100)