Abstract
In recent years, the usage of digital polymerase chain reaction (dPCR) for various clinical applications has increased exponentially. Considering the growing demand for improved dPCR technology, the Clarity Plus™ dPCR system which features enhanced multiplexing capability and a wider dynamic range for nucleic acid analysis was recently launched. In this study, a dPCR assay optimized for use on Clarity Plus™ was evaluated for the absolute quantification of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the causative agent responsible for the global coronavirus disease 2019 (COVID-19) outbreak. The assay demonstrated good inter- and intra-assay precision, accuracy, as well as excellent linearity across a range of over 6 orders of magnitude for target gene quantification. In addition, comparison of the assay on both dPCR and qPCR platforms revealed that dPCR exhibited a slightly higher sensitivity compared to its qPCR counterpart when quantifying SARS-CoV-2 at a lower concentration. Overall, the results showed that the dPCR assay is a reliable and effective approach for the absolute quantification of SARS-CoV-2 and can potentially be adopted as a molecular tool for detecting low viral load in patients and wastewater surveillance of COVID-19.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
Not applicable
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Footnotes
1902056{at}sit.singaporetech.edu.sg, milton{at}jnmedsys.com, huiyulow{at}jnmedsys.com, joy.pang{at}singaporetech.edu.sg
Data Availability
All data generated or analysed during this study are included in this published article (and its supplementary information files).