Abstract
[Objectives]The measurement of personal exposure has been attracting increased attention for the control of hazardous substances. Although the combination of location information and personal exposure is considered highly useful, to-this-date, no simple or highly accurate indoor positioning method has been presented. Recently, Wi-Fi round-trip time (RTT) has attracted scientific attention as a highly accurate indoor positioning method. In this study, we investigated the possibility of the use of a combination of this indoor positioning method and small-dust sensors.
[Methods]We measured indoor positioning and dust concentration three times during a walk in a simulated factory. A wearable particle monitor was worn on both upper arms, and a smartphone was attached to the helmet for positioning. An ultrasonic humidifier was used to spray sodium chloride solution in the factory. The measurements were conducted three times on different routes on foot (Experiment A, B, C).
[Results]In indoor positioning, the error percentages, i.e., measurements that were outside the correct measurement area were 7% (49 s/700 s) in Experiment A, 2.3% (15 s/660 s) in Experiment B, and 7.8% (50 s/645 s) in Experiment C. The dust measurements were also taken without interruption. A heat map was created based on the results of both measurements.
[Conclusions]Wi-Fi RTT was able to implement indoor positioning with high accuracy. Thus, the combination of indoor positioning and various sensors can be considered useful for occupational health.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This study was funded by the Industrial Disease Clinical Research Grant (180302-01).
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
All measurements in this study were performed by the authors and no subjects were involved. Therefore, the study was not reviewed by the Ethics Committee because it was not considered to meet the requirements for ethical review.
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Footnotes
Figure 5 incorrectly contained the image of Appendix 1, which has been replaced with the correct one.
Data Availability
The data that support the findings of this study are available from the corresponding author upon reasonable request.