Abstract
Diffusion Kurtosis Imaging (DKI) has undisputed advantages over more classical diffusion Magnetic Resonance Imaging (dMRI), as witnessed by a fast-increasing number of clinical applications and software packages widely adopted in brain imaging domain. Despite its power in probing tissue microstructure compared to conventional MRI, DKI is still largely underutilized in Spinal Cord (SC) imaging because of its inherently demanding technological requirements.
If state-of-the-art hardware advancements have recently allowed to make great strides in applying this emerging method to adult and child SC, the same does not apply to neonatal setting. Indeed, amplified technical issues related to SC district in this age range have made this field still unexplored. However, results arising from recent application of DKI to adult and child SC are promising enough to suggest how informative this technique would be in investigating newborns, too.
Due to its extreme sensitivity to non-gaussian diffusion, DKI proves particularly suitable for detecting complex, subtle, fast microstructural changes occurring in this area at this early and critical stage of development, and not identifiable with only DTI. Given the multiplicity of congenital anomalies of the spinal canal, their crucial effect on later developmental outcome, and the close interconnection between SC region and the above brain, managing to apply such a method to neonatal cohort becomes of utmost importance.
In this work, we illustrate the first semi-automated pipeline for handling with DKI data of neonatal SC, from acquisition setting to estimation of diffusion (DTI & DKI) measures, through accurate adjustment of processing algorithms customized for adult SC. Each processing step of this pipeline, built on Spinal Cord Toolbox (SCT) software, has undergone Quality Control check by supervision of an expert pediatric neuroradiologist, and the overall procedure has preliminarily been tested in a pilot clinical case study. Results of this application agree with findings achieved in a corresponding adult survey, thus confirming validity of adopted pipeline and diagnostic value of DKI in pediatrics. This novel tool hence paves the wave for extending its application also to other promising advanced dMRI models, such as Neurite Orientation Dispersion and Density Imaging (NODDI), and to a wider range of potential clinical applications concerning neonatal period.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
This single-center study was carried out in accordance with the recommendations of "Comitato Etico Regione Liguria, Genoa, Italy" with written informed parental consent obtained for each infant prior to examination in accordance with the Declaration of Helsinki.
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
Data used in this study is not able to be made openly available due to privacy restrictions of clinical data imposed by the Gaslini Hospital's administration. Regarding code availability, a specific pipeline compatible with SCT is integrated in an open-access GitHub repository within "SCT-pipeline", a site gathering various pipelines compatible with SCT for processing MRI data (https://github.com/sct-pipeline/pediatric-genova).