Abstract
Background Frequently SARS-CoV-2 results in mild or moderate disease with potentially lower concentrations of antibodies compared to those that are hospitalised. Here, we validated an ELISA using SARS-CoV-2 trimeric spike glycoprotein, with targeted detection of IgG, IgA and IgM (IgGAM) using serum and dried blood spots (DBS) from adults with mild or moderate disease.
Methods Targeting the SARS-CoV-2 trimeric spike, a combined anti-IgG, IgA and IgM serology ELISA assay was developed using 62 PCR-confirmed non-hospitalised, mild or moderate COVID-19 samples, ≥14 days post symptom onset and 624 COVID-19 negative samples. The assay was validated using 73 PCR-confirmed non-hospitalised COVID-19 and 359 COVID-19 negative serum samples with an additional 81 DBSs, and further validated in 226 PCR-confirmed non-hospitalised COVID-19 and 426 COVID-19 negative clinical samples.
Results A sensitivity and specificity of 98.6% (95% CI, 92.6–100.0), 98.3% (95% CI, 96.4–99.4), respectively, was observed following validation of the SARS-CoV-2 ELISA. No cross-reactivities with endemic coronaviruses or other human viruses were observed, and no change in results were recorded for interfering substances. The assay was stable at temperature extremes and components were stable for 15 days once opened. A matrix comparison showed DBS to correlate with serum results. Clinical validation of the assay reported a sensitivity of 94.7% (95% CI, 90.9-97.2%) and a specificity of 98.4% (95% CI, 96.6-99.3%).
Conclusions The human anti-IgGAM SARS-CoV-2 ELISA provides accurate and sensitive detection of SARS-CoV-2 antibodies in non-hospitalised adults with mild or moderate disease. The use of dried blood spots makes the assay accessible to the wider community.
Supplementary Material No
Competing Interest Statement
LJW, AMC, GW, SH & DK are members of The Binding Site Group Ltd.
Funding Statement
No external funding was received
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
Residual anonymised samples were used in this study from several sources. For the specificity and sensitivity analysis residual samples were from commercial sources (BioIVT, approved by Western Institutional Review Board - IRB20161665; TCS Bioscience approved by The Diagnostics Investigational Review Board- IRB112015-01.1; anonymised normal samples provided by Plasma Services Group were collected with patient consent via an FDA registered blood establishment (registration number 3005275238)) and further residual samples collected in accordance with REC 2002/201; South Birmingham Research Ethics Service. For dried blood spot comparison, residual anonymised samples were collected from University of Birmingham (REC 2002/201; South Birmingham Research Ethics Service). For cross reactivity analysis, samples were provided by the Amsterdam University Medical Center of the University of Amsterdam, the Netherlands (approved by the Medical Ethics Committee; MEC 07/182MEC 07/182).Samples were used in accordance with the world medical association declaration of Helsinki Ethical principles for Medical Research involving human subjects.
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
Due to the nature of this research, participants of this study did not agree for their data to be shared publicly, so supporting data is not available.
List of Abbreviations
- DBS
- Dried Blood Spots
- ELISA
- Enzyme Linked Immunosorbent Assay
- PCR
- Polymerase Chain Reaction
- SARS-CoV-2
- Severe Acute Respiratory Syndrome Coronavirus 2