Abstract
How often does one perform hand disinfection while wearing a mask? In the current COVID-19 pandemic, wearing masks and hand disinfection are widely adopted hygiene practices. However, our study indicated that exposure to the vapors from alcohol-based sanitizers during hand disinfection might degrade the filtration performance of the in-use masks, and the degradation worsened with the increasing number of hand disinfection. After five times of hand disinfection, the filtration efficiencies of surgical masks decreased by >8% for 400 and 500nm particles and by 3.68±1.83 % for 1μm particles. This was attributed to the dissipation of electrostatic charges on the masks when exposed to the alcohol vapor generated during hand disinfection. Simple practice of vapor-avoiding hand disinfection could mitigate the effects of alcohol vapor, which was demonstrated on two brands of surgical masks. The vapor-avoiding hand disinfection is recommended to be included in the hygiene guide to maintain the mask performance.
- COVID-19
- masks
- hand disinfection
- filtration efficiency
- charge decay
- vapor-avoiding
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
The work was partially supported by Innosuisse project 46668.1 IP-ENG ReMask: Strategies for innovations for Swiss masks needed in pandemic situations and Center for Filtration Research at University of Minnesota. We thank the support of National Science and Technology Major Project of China (Award ID: 2017YFC0211801; 2016YFC0801704; 2016YFC0203701; 2016YFC0801605; 2019JH2/10100004). The authors also thank the financial aid from the project of China Scholarship Council, China.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
No ethical approval was needed for the study.
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
All data used during the study appear in the submitted article.