ABSTRACT
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) was reported to WHO as an outbreak in Wuhan City, Hubei Province, China on end of 2019, afterwards epidemic in many countries, and pandemic on the worldwide in 2020.
Usually detection of coronavirus including SARS-CoV-2 was detected by real-time RT-PCR method, but it must be long time that RNA is treated by extraction, concentration and purification, and detected by RT-PCR method. We modified various methods, of which evaluated if each method is short and simple enough.
In one point of the evaluations, real-time RT-PCR could be finished in very short time with using mobile real-time PCR device PCR1100 (Nippon Sheet Glass Co. Ltd.). It was able to detect positive control RNA for 20 minutes by each method according to the National Institute of Infections Disease in Japan (NIID), and less than 13.5 minutes according to the Centers for Disease Control and Prevention in USA (CDC).
In another point of the evaluations, surprisingly, Human coronavirus 229E, which was substituted for SARS-CoV-2, could be detected in crude state without treatment in advance of RNA. As that was, it was possible to detect coronavirus with direct RT-PCR. Therefore, it might eliminate wasteful time, avoid secondary infection and risk of contamination.
In light of the above two points, SARS-CoV-2 might be detected more quickly and more simply. With using this mobile real-time PCR, these methods should be suitable for not only SARS-CoV-2 but also other various viruses and might save time compared to earlier detection methods.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
No external funding was received to me this time.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
I did not have to be obtained necessary IRB and/or ethics committee approvals in this time.
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
The data that support the findings of this study are openly available at each URL each reference number in this manuscript.