Abstract
Background Hand rehabilitation is core to helping stroke survivors regain activities of daily living. Recent studies have suggested that the use of electroencephalography-based brain-computer interfaces (BCI) can promote this process. Here, we report the first systematic examination of the literature on the use of BCI-robot systems for the rehabilitation of fine motor skills associated with hand movement and profile these systems from a technical and clinical perspective.
Methods A search for January 2010-October 2019 articles using Ovid MEDLINE, Embase, PEDro, PsycINFO, IEEE Xplore and Cochrane Library databases was performed. The selection criteria included BCI-hand robotic systems for rehabilitation at different stages of development involving tests on healthy participants or people who have had a stroke. Data fields include those related to study design, participant characteristics, technical specifications of the system, and clinical outcome measures.
Results 30 studies were identified as eligible for qualitative review and among these, 11 studies involved testing a BCI-hand robot on chronic and subacute stroke patients. Statistically significant improvements in motor assessment scores relative to controls were observed for three BCI-hand robot interventions. The degree of robot control for the majority of studies was limited to triggering the device to perform grasping or pinching movements using motor imagery. Most employed a combination of kinaesthetic and visual response via the robotic device and display screen, respectively, to match feedback to motor imagery.
Conclusion 19 out of 30 studies on BCI-robotic systems for hand rehabilitation report systems at prototype or pre-clinical stages of development. We identified large heterogeneity in reporting and emphasise the need to develop a standard protocol for assessing technical and clinical outcomes so that the necessary evidence base on efficiency and efficacy can be developed.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This work was supported by a Newton Fund PhD grant, ID 331486777, under the Newton-Agham partnership. The grant is funded by the UK Department for Business, Energy and Industrial Strategy and the Philippine Commission on Higher Education and delivered by the British Council. For further information, please visit www.newtonfund.ac.uk.
Author Declarations
All relevant ethical guidelines have been followed; any necessary IRB and/or ethics committee approvals have been obtained and details of the IRB/oversight body are included in the manuscript.
Yes
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Footnotes
Second revision according to reviewers' comments
Data Availability
A full database of selected studies including those extracted during the search and selection process is available from the corresponding author on reasonable request.
List of Abbreviations
- ADL
- Activities of Daily Living
- ANN
- Artificial Neural Network
- AO
- Action Observation
- AR
- Augmented Reality
- ARAT
- Action Research Arm Test
- BCI
- Brain-Computer Interface
- BMI
- Brain-Machine Interface
- CDRH
- Center for Devices and Radiological Health
- CNN
- Convolutional Neural Network
- CSD
- Covariate Shift Detection
- CSP
- Common Spatial Pattern
- DC
- Direct Current
- ECoG
- Electrocorticography
- EEG
- Electroencephalography
- EMG
- Electromyography
- EOG
- Electrooculography
- ERD
- Event-Related Desynchronisation
- ERP
- Event-Related Potential
- ERS
- Event-Related Synchronisation
- ERSP
- Event-Related Spectral Perturbation
- FBCSP
- Filter Bank Common Spatial Pattern
- FIR
- Finite Impulse Response
- FMA-UE
- Fugl-Meyer Motor Assessment – Upper Extremity
- GS
- Grip Strength
- IIR
- Infinite Impulse Response
- LDA
- Linear Discriminant Analysis
- ME
- Motor Execution
- MI
- Motor Imagery
- PEDro
- Physiotherapy Evidence Database
- PMA
- Premarket Approval
- PRISMA
- Preferred Reporting Items for Systematic Reviews and Meta-Analysis
- PROSPERO
- International Prospective Register of Systematic Reviews
- PS
- Pinch Strength
- QSR
- Quality System Requirement
- RCT
- Randomised Clinical Trial
- RNN
- Recurrent Neural Network
- SAT
- Standard Arm Therapy
- SVM
- Support Vector Machine
- TRA
- Technology Readiness Assessment
- TRL
- Technology Readiness Levels
- UK-MRC
- United Kingdom Medical Research Council
- VR
- Virtual Reality