Abstract
IMPORTANCE The rapid genetic evolution of SARS-CoV-2 and in particular the highly contagious Omicron variant of concern (VoC) may pose problems for rapid and accurate diagnosis of infection.
OBJECTIVE Determine the diagnostic accuracy and robustness of a second generation rapid antigen tests compared to gold-standard, PCR-based diagnostics, for detection of infection with different SARS-CoV-2 Omicron VoC sub lineages in health care workers.
DESIGN, SETTING, AND PARTICIPANTS The study included 428 health care workers from the University Hospital Munich Rechts der Isar of the Technical University of Munich who either reported recent onset of COVID-19 associated symptoms or completed routine diagnostic testing between 24th of May and 22nd of September 2022. All participants gave written informed consent to participate in this study and completed a questionnaire on infection-associated symptoms, prior SARS-CoV-2 infections and vaccination status.
INTERVENTIONS During the first visit, two nasal swabs and one oropharyngeal swab were taken to perform two rapid antigen tests and a SARS-CoV-2 PCR-assay, respectively. A second set of nasal swabs was taken by the participants themselves two days later to repeat the two rapid antigen tests.
MAIN OUTCOMES AND MEASURES The accuracy for detection of infection with different SARS-CoV-2 Omicron VoCs with two rapid antigen tests (Test I and Test II) was determined and compared to quantitative SARS-CoV-2 RNA levels detected by PCR.
RESULTS In a side-by-side comparison, we found that Test I detected viral nucleocapsids from Omicron VoC (BA.5.2.3) at higher dilutions compared to Test II. In the 428 health care workers, Test I and Test II detected PCR-confirmed SARS-CoV-2 infection with different Omicron VoCs (BA.2, BA.4, BA.5) with a sensitivity of 89.4% (95% CI 81.9% - 94.6%) and 83.7% (95% CI 75.12% - 90.18%), respectively. Increased sensitivity of Test I was also reflected by earlier detection of SARS-CoV-2 infection. The lower test sensitivity of Test II could be compensated for by a repeated test performed two days later.
CONCLUSIONS AND RELEVANCE Our study demonstrates that rapid antigen tests are suited to detect infection with the SARS-CoV-2 Omicron VoC and reveal an advantage of a lower detection limit for earlier detection of infection in health care workers.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This study did not receive any funding. Reagents or direct assay costs were covered by Roche.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
Ethics committee of the Technical University of Munich. Approval Number 2022-265-S-Art.74-SR
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Footnotes
↵* shared first and last authorship
Data Availability
All data produced in the present work are contained in the manuscript