Abstract
Amblyopia is a neurodevelopmental visual disorder that affects approximately 3-5% of children globally and it can lead to vision loss if it is not diagnosed and treated early. Traditional diagnostic methods, which rely on subjective assessments and expert interpretation of eye movement recordings presents challenges in resource-limited eye care centers. This study introduces a new approach that integrates the Gemini large language model (LLM) with eye-tracking data to develop a classification tool for diagnosis of patients with amblyopia. The study demonstrates: (1) LLMs can be successfully applied to the analysis of fixation eye movement data to diagnose patients with amblyopia; and (2) Input of medical subject matter expertise, introduced in this study in the form of medical expert augmented generation (MEAG), is an effective adaption of the generic retrieval augmented generation (RAG) approach for medical applications using LLMs. This study introduces a new multi-view prompting framework for ophthalmology applications that incorporates fine granularity feedback from pediatric ophthalmologist together with in-context learning to report an accuracy of 80% in diagnosing patients with amblyopia. In addition to the binary classification task, the classification tool is generalizable to specific subpopulations of amblyopic patients based on severity of amblyopia, type of amblyopia, and with or without nystagmus. The model reports an accuracy of: (1) 83% in classifying patients with moderate or severe amblyopia, (2) 81% in classifying patients with mild or treated amblyopia; and (3) 85% accuracy in classifying patients with nystagmus. To the best of our knowledge, this is the first study that defines a multiview prompting framework with MEAG to analyze eye tracking data for the diagnosis of amblyopic patients.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This research was funded in part by grants from the US National Institutes of Health (NIH), U24EB029005, R01DA053028, the US Department of Defense (DoD) grant W81XWH2110859, and the Clinical and Translational Science Collaborative of Cleveland, which is funded by the NIH, National Center for Advancing Translational Sciences, Clinical and Translational Science Award grant, UL1TR002548. The content is solely the responsibility of the authors and does not necessarily represent the official views of the NIH.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
This study was reviewed and approved by the Cleveland Clinic Institutional Review Board (IRB). Written informed consent was obtained from each participant or parent/legal guardian for this study as mandated by the Declaration of Helsinki. The patient data with protected health information (PHI) elements was securely stored at Cleveland Clinic and only the deidentified data was subsequently shared with Case Western Reserve University for analysis by the transformer deep learning model.
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.
Yes
Footnotes
↵✉ satya.sahoo{at}case.edu
{dipak.upadhyaya{at}case.edu, katrina.prantzalos{at}case.edu, pedram.golnari{at}case.edu, aasef.shaikh{at}case.edu,}
{ghasiaf{at}ccf.org, cakrig{at}ccf.org}
Amblyopia is a neurodevelopmental visual disorder that affects approximately 3-5% of children globally and it can lead to vision loss if it is not diagnosed and treated early. Traditional diagnostic methods, which rely on subjective assessments and expert interpretation of eye movement recordings presents challenges in resource-limited eye care centers. This study introduces a new approach that integrates the Gemini large language model (LLM) with eye-tracking data to develop a classification tool for diagnosis of patients with amblyopia. The study demonstrates: (1) LLMs can be suc-cessfully applied to the analysis of fixation eye movement data to diagnose patients with amblyopia; and (2) Input of medical subject matter expertise, introduced in this study in the form of medical expert augmented generation (MEAG), is an effective adaption of the generic retrieval augmented generation (RAG) approach for medical applications using LLMs. This study introduces a new multi-view prompting framework for ophthalmology applications that incorporates fine granularity feedback from pediatric ophthalmologist together with in-context learning to report an accuracy of 80% in diagnosing patients with amblyopia. In addition to the binary classification task, the classification tool is generalizable to specific subpopulations of amblyopic patients based on severity of amblyopia, type of amblyopia, and with or without nystagmus. The model reports an accuracy of: (1) 83% in classifying patients with moderate or severe amblyopia, (2) 81% in classifying patients with mild or treated amblyopia; and (3) 85% accuracy in classifying patients with nystagmus. To the best of our knowledge, this is the first study that defines a multi-view prompting framework with MEAG to analyze eye tracking data for the diagnosis of amblyopic patients.
Data Availability
Available upon reasonable request.