Software-defined Radar for MRI Motion Correction: A versatile, vendor-independent Platform
View ORCID ProfileChristoph Maier, View ORCID ProfileEddy Solomon, George Verghese, View ORCID ProfileHersh Chandarana, View ORCID ProfileKai Tobias Block, View ORCID ProfileLeeor Alon
doi: https://doi.org/10.64898/2026.05.16.26351399
Christoph Maier
1Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
2Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
Eddy Solomon
3Department of Biomedical Engineering, Technion – Israel Institute of Technology: Haifa, Israel
George Verghese
1Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
2Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
Hersh Chandarana
1Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
2Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
Kai Tobias Block
1Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
2Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
Leeor Alon
1Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States
2Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University Grossman School of Medicine, New York, NY, United States

Data Availability Statement
Software and data used in the phantom experiments are currently being prepared for public release and will be available following formal acceptance of the manuscript. Due to regulatory restrictions, volunteer data cannot be shared publicly.
Posted May 21, 2026.
Software-defined Radar for MRI Motion Correction: A versatile, vendor-independent Platform
Christoph Maier, Eddy Solomon, George Verghese, Hersh Chandarana, Kai Tobias Block, Leeor Alon
medRxiv 2026.05.16.26351399; doi: https://doi.org/10.64898/2026.05.16.26351399
Subject Area
Subject Areas
- Addiction Medicine (638)
- Allergy and Immunology (922)
- Anesthesia (354)
- Cardiovascular Medicine (5026)
- Dermatology (430)
- Emergency Medicine (680)
- Epidemiology (16291)
- Forensic Medicine (36)
- Gastroenterology (1243)
- Genetic and Genomic Medicine (7300)
- Geriatric Medicine (755)
- Health Economics (1095)
- Health Informatics (5311)
- Health Policy (1476)
- Hematology (599)
- HIV/AIDS (1383)
- Medical Education (701)
- Medical Ethics (157)
- Nephrology (754)
- Neurology (7626)
- Nursing (380)
- Nutrition (1134)
- Obstetrics and Gynecology (1297)
- Oncology (3752)
- Ophthalmology (1097)
- Orthopedics (411)
- Otolaryngology (468)
- Pain Medicine (503)
- Palliative Medicine (143)
- Pathology (722)
- Pediatrics (1864)
- Primary Care Research (788)
- Public and Global Health (10021)
- Radiology and Imaging (2544)
- Respiratory Medicine (1274)
- Rheumatology (663)
- Sports Medicine (600)
- Surgery (806)
- Toxicology (109)
- Transplantation (320)
- Urology (309)




