Article Text

Download PDFPDF

Use of exhaled breath condensate (EBC) in the diagnosis of SARS-COV-2 (COVID-19)
Free
  1. Daniel J Ryan1,2,
  2. Sinead Toomey1,
  3. Stephen F Madden3,
  4. Michelle Casey2,
  5. Oscar S Breathnach4,
  6. Patrick G Morris4,
  7. Liam Grogan4,
  8. Peter Branagan2,
  9. Richard W Costello2,
  10. Eoghan De Barra5,
  11. Killian Hurley2,
  12. Cedric Gunaratnam2,
  13. Noel G McElvaney2,
  14. Michael Emmet OBrien2,
  15. Imran Sulaiman2,
  16. Ross K Morgan2,
  17. Bryan T Hennessy1,4
  1. 1 Department of Molecular Medicine, Royal College of Surgeons in Ireland, Dublin, Ireland
  2. 2 Department of Respiratory Medicine, Beaumont Hospital, Dublin, Ireland
  3. 3 Data Science Centre, Royal College of Surgeons in Ireland, Dublin, Ireland
  4. 4 Department of Oncology, Beaumont Hospital, Dublin, Ireland
  5. 5 Department of International Health and Tropical Medicine, Royal College of Surgeons in Ireland, Dublin, Ireland
  1. Correspondence to Dr Daniel J Ryan, Department of Molecular Medicine, Royal College of Surgeons in Ireland, Dublin, Ireland; danennis100{at}gmail.com

Abstract

False negatives from nasopharyngeal swabs (NPS) using reverse transcriptase PCR (RT-PCR) in SARS-CoV-2 are high. Exhaled breath condensate (EBC) contains lower respiratory droplets that may improve detection. We performed EBC RT-PCR for SARS-CoV-2 genes (E, S, N, ORF1ab) on NPS-positive (n=16) and NPS-negative/clinically positive COVID-19 patients (n=15) using two commercial assays. EBC detected SARS-CoV-2 in 93.5% (29/31) using the four genes. Pre-SARS-CoV-2 era controls (n=14) were negative. EBC was positive in NPS negative/clinically positive patients in 66.6% (10/15) using the identical E and S (E/S) gene assay used for NPS, 73.3% (11/15) using the N/ORF1ab assay and 14/15 (93.3%) combined.

  • exhaled airway markers
  • respiratory infection
  • viral infection

This article is made freely available for use in accordance with BMJ’s website terms and conditions for the duration of the covid-19 pandemic or until otherwise determined by BMJ. You may use, download and print the article for any lawful, non-commercial purpose (including text and data mining) provided that all copyright notices and trade marks are retained.

https://bmj.com/coronavirus/usage

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Introduction

COVID-19 is routinely diagnosed by detection of SARS-CoV-2 viral RNA via reverse transcription PCR (RT-PCR) from nasopharyngeal swabs (NPS).1 Target genes include spike surface glycoprotein (S), small envelope protein (E), nucleocapsid protein (N) and RNA dependant RNA polymerase (ORF1ab).2 WHO guidelines recommend identification of one of these targets for diagnosis of COVID-19 in high prevalence areas.3 Negative NPS results do not outrule infection and in patients with a suspicion of COVID-19 and negative NPS, lower respiratory tract sampling is recommended.4 Bronchoalveolar lavage and tracheal aspirates are invasive and impractical in COVID-19. Novel, non-invasive options representing the lower respiratory tract should be explored.

Exhaled breath condensate (EBC) contains respiratory droplets representing the lower airways. We have previously detected DNA mutations in EBC from patients with lung cancer,5 and EBC RT-PCR has been used to identify respiratory viruses including coronavirus.6 We hypothesised that EBC can detect SARS-CoV-2 and aid diagnosis in NPS-negative patients with suspected COVID-19.

Methods

This was a prospective, observational, proof-of-concept study. Patients were recruited from the hospital COVID-19 pathway (designed to triage patients with a potential diagnosis of COVID-19) between 6 April and 8 May 2020. Patients were recruited if they could give informed written consent, perform EBC testing and had clinical and radiological evidence of COVID-19 or a clear alternative diagnosis. Forty patients were recruited and divided into three groups: (1) SARS-CoV-2 NPS positive, (2) NPS negative with a clinical diagnosis of COVID-19 and (3) NPS negative with other clinical diagnoses. Clinical diagnosis of COVID-19 was confirmed using expert clinical opinion and characteristic imaging.7 Fourteen samples obtained before the emergence of SARS-CoV-2 from patients with lung cancer were included as negative controls. Where possible, we serologically tested patients who were NP-swab negative with a clinical diagnosis of COVID-19 to validate our results.

Sample collection and processing

EBC was collected using the RTube condenser (Respiratory Research Inc, Charlottesville, Virginia, USA). Patients were instructed to breathe through the mouthpiece for 2 min. RNA was extracted from 140 µL of EBC using the QIAamp viral RNA mini kit (Qiagen) and eluted in 50 µL of buffer. RT-PCR for the E and S genes (E/S) was performed using the RealStar SARS-CoV-2 RT-PCR kit (altona Diagnostics), as used for the NPS. The N and ORF1ab (N/ORF1ab) genes were analysed using the COVID-19 (SARS-CoV-2) Triplex RT-qPCR detection kit (Assay Genie). Assays were performed on the Applied Biosystems 7500 instrument. EBC was deemed positive for SARS-CoV-2 if at least one of the four genes tested positive. Serological analysis was performed using the anti-SARS-CoV-2 antibody test (Roche Diagnostics).

Results

Patients

Of the 40 patients recruited, 16 (40%) were NPS positive, 15 (37.5%) were NPS negative (median negative NPS 2, range 2–3) with a clinical diagnosis of COVID-19 and 9 (22.5%) were NPS negative with other clinical diagnoses including pulmonary emboli (2), new lung cancers (2), cavitating pneumonia (1), pulmonary nodules (1), and three patients with normal lung imaging. One of these had methicillin-sensitive Staphylococcus aureus septicaemia and two had costochondritis. Baseline characteristics of prospectively enrolled patients are included in table 1. Nine out of 15 patients with negative NPS but clinical diagnosis of COVID-19 had serology performed. Of the remaining six, three had died, two did not consent to testing and one was uncontactable.

Table 1

Clinical characteristics of NPS positive, NPS negative/clinically positive and NPS negative/other clinical diagnoses

Exhaled breath condensate

In patients with a positive NPS and those with a negative NPS but clinical diagnosis of COVID-19, EBC RT-PCR was positive for SARS-CoV-2 in 21/31 (68%) of cases using the identical two-gene (E/S) assay kit used for NPS testing. Detection increased to 29/31 (93.5%) when EBC RT-PCR was performed using four gene targets (S/E/N/ORF1ab). In the clinically positive but NPS-negative group, EBC was positive in 66.6% (10/15) using the E/S assay (figure 1A), 73.3% (11/15) using the N/ORF1ab assay (figure 1B) and 93.3% (14/15) using the four genes. Eight of the nine (89%) NPS negative with other clinical diagnoses patients had negative EBC. One patient with a new diagnosis of lung cancer tested positive despite low clinical suspicion. None of the 14 samples in the pre-SARS-CoV-2 era control group tested positive. Serology testing was carried out on patients with a negative NPS but clinical diagnosis of COVID-19 at a median of 34 (range 24–51) days postsymptom onset. Six out of nine (66.6%) patients had positive antibodies. All nine corresponding EBC samples were positive for SARS-CoV-2.

Figure 1

Exhaled breath condensate (EBC) reverse transcriptase PCR for SARS-CoV-2. The proportion of positive and negative results for EBC reverse transcriptase PCR (EBC RT-PCR) for SARS-CoV-2 in the different clinical cohorts are shown for (A) E and S genes and (B) N and ORF1ab genes. Figure 1A also highlights the proportion of NPS-positive patients that tested negative using EBC RT-PCR, 5/16 (31%).

Discussion

Our study supports the hypothesis that EBC can identify SARS-CoV-2 by RT-PCR and that testing multiple genes together increases detection. False negative rates approaching 30% are reported using NPS RT-PCR,8 with detection dropping up to 40% after 5 days of symptoms.9 For our study, the median number of days patients were symptomatic prior to admission was 7 (range 2–20). Despite this, EBC detected SARS-CoV-2 in 66.6% (10/15) (E/S assay), 73.3% (11/15) (N/ORF1ab assay) and 93.3% (14/15) (all four genes) of NPS-negative patients with a clinical diagnosis of COVID-19.

The study has limitations. Power calculations indicated a need for 155 samples to detect a statistically significant difference between NPS and EBC RT-PCR using the same E/S assay with an 80% power and alpha value of 0.05. However, increased sample size was not possible due to decreased admissions in response to public health measures. EBC RT-PCR failed to identify SARS-CoV-2 in 5/16 (31%) NPS-positive cases using the identical E/S assay, suggesting EBC should be used as an adjunct rather than a replacement for NPS RT-PCR. Owing to strict laboratory access restrictions and some patients being initially too unwell to provide samples, EBC collection occurred a median of 2 days (range 0–19) after NPS testing, potentially introducing bias favouring EBC detection. Three out of nine (33.3%) patients had no evidence of antibodies to COVID-19 despite having positive EBC RT-PCR. However, median time to serology was 34 days (range 34–51), and currently few data are available to confirm continued antibody response 35 days post infection, particularly in milder cases.10

In conclusion, this study provides promising results that EBC RT-PCR is an effective, non-invasive method of identifying SARS-CoV-2 from lower respiratory tract samples and should be considered to aid diagnosis of COVID-19 in patients with a high suspicion of infection but negative NPS.

References

Footnotes

  • DJR and ST are joint first authors.

  • RKM and BTH are joint senior authors.

  • Contributors DR and ST: joint first authors responsible for drafting, conception, design, acquisition, analysis and interpretation. SM: data analysis and interpretation. MC, OB, PGM and LG: data acquisition and analysis. EDB, PB, RWC, KH, CG, NGM, MEO and IS: data acquisition and analysis. RM and BH: joint senior authors responsible for conception, design and drafting of the manuscript for important intellectual content.

  • Funding This study was funded by a Science Foundation Ireland COVID Rapid Response Call grant (20/COV/0109) and the North East Cancer Research and Education Trust (NECRET: Grant no. 1696).

  • Competing interests None declared.

  • Patient consent for publication Not required.

  • Ethics approval Beaumont Hospital Ethics (Medical Research) Committee, Dublin, Ireland (March 31st 2020) REC REF: 20/39.

  • Provenance and peer review Not commissioned; externally peer reviewed.