Hypoxia tolerance in reptiles, amphibians, and fishes: life with variable oxygen availability

PE Bickler, LT Buck - Annu. Rev. Physiol., 2007 - annualreviews.org
The ability of fishes, amphibians, and reptiles to survive extremes of oxygen availability derives
from a core triad of adaptations: profound metabolic suppression, tolerance of ionic and …

Effects of skin pigmentation on pulse oximeter accuracy at low saturation

PE Bickler, JR Feiner… - The Journal of the …, 2005 - pubs.asahq.org
Background It is uncertain whether skin pigmentation affects pulse oximeter accuracy at low
HbO2 saturation. Methods The accuracy of finger pulse oximeters during stable, plateau …

Dark skin decreases the accuracy of pulse oximeters at low oxygen saturation: the effects of oximeter probe type and gender

JR Feiner, JW Severinghaus, PE Bickler - Anesthesia & Analgesia, 2007 - journals.lww.com
METHODS: We studied the relationship between skin pigment and oximeter accuracy in 36
subjects (19 males, 17 females) of a range of skin tones. Clip-on type sensors and adhesive/…

Factors affecting the performance of 5 cerebral oximeters during hypoxia in healthy volunteers

PE Bickler, JR Feiner, MD Rollins - Anesthesia & Analgesia, 2013 - journals.lww.com
BACKGROUND: Cerebral oximetry is a noninvasive optical technology that measures frontal
cortex blood hemoglobin-oxygen saturation. Commercially available cerebral oximeters …

Dual effects of anandamide on NMDA receptor‐mediated responses and neurotransmission

…, DJ Leonoudakis, PE Bickler - Journal of …, 1998 - Wiley Online Library
Anandamide is an endogenous ligand of cannabinoid receptors that induces
pharmacological responses in animals similar to those of cannabinoids such as Δ 9 ‐tetrahydrocannabinol …

Delayed environmental enrichment reverses sevoflurane-induced memory impairment in rats

…, RS Alvi, JW Sall, V Rau, PE Bickler… - The Journal of the …, 2012 - pubs.asahq.org
Background Anesthesia given to immature rodents causes cognitive decline, raising the
possibility that the same might be true for millions of children undergoing surgical procedures …

Pulse oximeter performance, racial inequity, and the work ahead

…, M Bernstein, JR Feiner, PE Bickler - Respiratory …, 2022 - rc.rcjournal.com
It has long been known that many pulse oximeters function less accurately in patients with
darker skin. Reasons for this observation are incompletely characterized and potentially …

Consensus statement: first international workshop on anesthetics and Alzheimer's disease

D Baranov, PE Bickler, GJ Crosby, DJ Culley… - Anesthesia & …, 2009 - journals.lww.com
IMPLICATIONS This article is a consensus view on the possible link between Alzheimer’s
disease and anesthesia and the steps required to test this more definitively. From the* …

The accuracy of 6 inexpensive pulse oximeters not cleared by the Food and Drug Administration: the possible global public health implications

…, JR Feiner, P Au, M Bernstein, PE Bickler - Anesthesia & …, 2016 - journals.lww.com
BACKGROUND: Universal access to pulse oximetry worldwide is often limited by cost and
has substantial public health consequences. Low-cost pulse oximeters have become …

Four types of pulse oximeters accurately detect hypoxia during low perfusion and motion

A Louie, JR Feiner, PE Bickler, L Rhodes… - …, 2018 - pubs.asahq.org
Background Pulse oximeter performance is degraded by motion artifacts and low perfusion.
Manufacturers developed algorithms to improve instrument performance during these …