User profiles for Katleen Van Uytfanghe
Katleen Van UytfangheLaboratory of Toxicology, Ghent University Verified email at ugent.be Cited by 2508 |
Isotope-dilution liquid chromatography–tandem mass spectrometry candidate reference method for total testosterone in human serum
…, HC Cooper, SSC Tai, KV Uytfanghe… - Clinical …, 2013 - academic.oup.com
BACKGROUND We developed and evaluated a candidate reference measurement procedure
(RMP) to standardize testosterone measurements, provide highly accurate and precise …
(RMP) to standardize testosterone measurements, provide highly accurate and precise …
Candidate Reference Measurement Procedures for Serum 25-Hydroxyvitamin D3 and 25-Hydroxyvitamin D2 by Using Isotope-Dilution Liquid Chromatography …
…, A Vanderroost, K Van Uytfanghe… - Clinical …, 2011 - academic.oup.com
BACKGROUND 25-hydroxyvitamin D [25(OH)D] assays are characterized by poor between-assay
comparability. This result emphasizes the need for reference measurement …
comparability. This result emphasizes the need for reference measurement …
Report of the IFCC Working Group for Standardization of Thyroid Function Tests; part 2: free thyroxine and free triiodothyronine
LM Thienpont, K Van Uytfanghe, G Beastall… - Clinical …, 2010 - academic.oup.com
Background: Free thyroxine (FT4) and free triiodothyronine (FT3) measurements are useful
in the diagnosis and treatment of a variety of thyroid disorders. The IFCC Scientific Division …
in the diagnosis and treatment of a variety of thyroid disorders. The IFCC Scientific Division …
State-of-the-art of serum testosterone measurement by isotope dilution–liquid chromatography–tandem mass spectrometry
LM Thienpont, K Van Uytfanghe, S Blincko… - Clinical …, 2008 - academic.oup.com
Background: The recent interest of clinical laboratories in developing serum testosterone
assays based on isotope dilution–liquid chromatography–tandem mass spectrometry (ID-LC-…
assays based on isotope dilution–liquid chromatography–tandem mass spectrometry (ID-LC-…
Report of the IFCC Working Group for Standardization of Thyroid Function Tests; part 1: thyroid-stimulating hormone
LM Thienpont, K Van Uytfanghe, G Beastall… - Clinical …, 2010 - academic.oup.com
Background: Laboratory testing of serum thyroid-stimulating hormone (TSH) is an essential
tool for the diagnosis and management of various thyroid disorders whose collective …
tool for the diagnosis and management of various thyroid disorders whose collective …
Toward standardization of insulin immunoassays
WG Miller, LM Thienpont, K Van Uytfanghe… - Clinical …, 2009 - academic.oup.com
Background: Measurement of circulating insulin may improve the classification and management
of diabetes mellitus and assist in treating people with insulin resistance. Methods: A …
of diabetes mellitus and assist in treating people with insulin resistance. Methods: A …
Determination of free thyroid hormones
LM Thienpont, K Van Uytfanghe, K Poppe… - Best Practice & …, 2013 - Elsevier
Timely diagnosis and treatment of thyroid dysfunction is compelling given the prevalence and
severity of the disease. It requires reliance on adequate laboratory testing of serum TSH as …
severity of the disease. It requires reliance on adequate laboratory testing of serum TSH as …
Synthesis, chemical characterization, and μ-opioid receptor activity assessment of the emerging group of “nitazene” 2-benzylbenzimidazole synthetic opioids
MM Vandeputte, K Van Uytfanghe… - ACS Chemical …, 2021 - ACS Publications
Several 2-benzylbenzimidazole opioids (also referred to as “nitazenes”) recently emerged
on the illicit market. The most frequently encountered member, isotonitazene, has been …
on the illicit market. The most frequently encountered member, isotonitazene, has been …
Report on a novel emerging class of highly potent benzimidazole NPS opioids: chemical and in vitro functional characterization of isotonitazene
…, A Cannaert, K Van Uytfanghe… - Drug Testing and …, 2020 - Wiley Online Library
This paper reports on the identification and full chemical characterization of isotonitazene (N,N‐diethyl‐2‐[5‐nitro‐2‐({4‐[(propan‐2‐yl)oxy]phenyl}methyl)‐1H‐benzimidazol‐1‐yl]ethan…
FT4 immunoassays may display a pattern during pregnancy similar to the equilibrium dialysis ID–LC/tandem MS candidate reference measurement procedure in spite …
E Anckaert, K Poppe, K Van Uytfanghe… - Clinica Chimica …, 2010 - Elsevier
BACKGROUND: Serum free thyroxine (FT4) testing in pregnancy is known to be challenging
for immunoassays (IAs). We verified the reliability of FT4 results by 3 commercial IAs …
for immunoassays (IAs). We verified the reliability of FT4 results by 3 commercial IAs …