User profiles for Stephen C. Moore

Stephen C. Moore

Adjunct Associate Professor of Radiology, University of Pennsylvania
Verified email at pennmedicine.upenn.edu
Cited by 5152

Clinical myocardial perfusion PET/CT

…, G El Fakhri, A Sitek, SC Moore - Journal of Nuclear …, 2007 - Soc Nuclear Med
The field of nuclear cardiology is witnessing growing interest in the use of cardiac PET for
the evaluation of patients with coronary artery disease (CAD). The available evidence …

Imaging cardiac amyloidosis: a pilot study using 18F-florbetapir positron emission tomography

…, C Strader, JR Bruyere, MF Di Carli, SC Moore… - European journal of …, 2014 - Springer
Purpose Cardiac amyloidosis, a restrictive heart disease with high mortality and morbidity,
is underdiagnosed due to limited targeted diagnostic imaging. The primary aim of this study …

Quantification of myocardial perfusion reserve using dynamic SPECT imaging in humans: a feasibility study

…, A Sitek, N Roth, J Fantony, SC Moore… - Journal of Nuclear …, 2013 - Soc Nuclear Med
Myocardial perfusion imaging (MPI) is well established in the diagnosis and workup of patients
with known or suspected coronary artery disease (CAD); however, it can underestimate …

Mitochondrial iron chelation ameliorates cigarette smoke–induced bronchitis and emphysema in mice

…, ZH Chen, MP Goldklang, GC Yuan, SC Moore… - Nature medicine, 2016 - nature.com
Chronic obstructive pulmonary disease (COPD) is linked to both cigarette smoking and genetic
determinants. We have previously identified iron-responsive element–binding protein 2 (…

SNMMI/ASNC/SCCT Guideline for Cardiac SPECT/CT and PET/CT 1.0

…, PA Kaufmann, J Mahmarian, SC Moore… - Journal of Nuclear …, 2013 - Soc Nuclear Med
Each practice guideline, representing a policy statement by the SNMMI, has undergone a
thorough consensus process in which it has been subjected to extensive review, requiring the …

Quantitative dynamic cardiac 82Rb PET using generalized factor and compartment analyses

…, MF Kijewski, MF Di Carli, SC Moore - Journal of nuclear …, 2005 - Soc Nuclear Med
We have addressed 2 major challenges of 82 Rb cardiac PET, noninvasive estimation of an
accurate input function and absolute quantitation of myocardial perfusion, using a …

Review of SPECT collimator selection, optimization, and fabrication for clinical and preclinical imaging

…, C Vanhove, SD Metzler, SC Moore - Medical …, 2015 - Wiley Online Library
In single photon emission computed tomography, the choice of the collimator has a major
impact on the sensitivity and resolution of the system. Traditional parallel‐hole and fan‐beam …

[HTML][HTML] Validation of a previous-day recall measure of active and sedentary behaviors

…, K Lyden, HR Bowles, SC Moore… - Medicine and science …, 2013 - ncbi.nlm.nih.gov
Purpose A previous-day recall (PDR) may be a less error prone alternative to traditional
questionnaire-based estimates of physical activity and sedentary behavior (eg, past year), but …

Collimator design for single photon emission tomography

SC Moore, K Kouris, I Cullum - European journal of nuclear medicine, 1992 - Springer
We discuss recent trends in collimator design and technology, with emphasis on theoretical
and practical issues of importance for single photon emission tomography (SPET). The well-…

Assessment of myocardial perfusion and function with PET and PET/CT

MH Al-Mallah, A Sitek, SC Moore, M Di Carli… - Journal of Nuclear …, 2010 - Elsevier
Over the past decade, there has been a growing interest in cardiac imaging with Positron
Emission Tomography (PET). However, PET has been used for more than 35 years as a …