User profiles for Riccardo Ferrari

Riccardo MG Ferrari

Associate Prof. at Delft Center for Systems and Control, Delft University of Technology
Verified email at tudelft.nl
Cited by 1624

Distributed fault detection and isolation of large-scale discrete-time nonlinear systems: An adaptive approximation approach

RMG Ferrari, T Parisini… - IEEE Transactions on …, 2011 - ieeexplore.ieee.org
This paper deals with the problem of designing a distributed fault detection and isolation
methodology for nonlinear uncertain large-scale discrete-time dynamical systems. As a divide …

A distributed networked approach for fault detection of large-scale systems

F Boem, RMG Ferrari, C Keliris… - … on Automatic Control, 2016 - ieeexplore.ieee.org
Networked systems present some key new challenges in the development of fault-diagnosis
architectures. This paper proposes a novel distributed networked fault detection …

Hepatocellular carcinoma: detection with triple-phase multi–detector row helical CT in patients with chronic hepatitis

A Laghi, R Iannaccone, P Rossi, I Carbone, R Ferrari… - Radiology, 2003 - pubs.rsna.org
PURPOSE: To evaluate whether the use of two arterial phase image acquisition series,
when combined with portal venous phase imaging at multi–detector row helical computed …

Distributed fault diagnosis with overlapping decompositions: An adaptive approximation approach

RMG Ferrari, T Parisini… - IEEE Transactions on …, 2009 - ieeexplore.ieee.org
This technical note deals with the problem of designing a distributed fault detection
methodology for distributed (and possibly large-scale) nonlinear dynamical systems that are …

Usage of structured reporting in radiological practice: results from an Italian online survey

L Faggioni, F Coppola, R Ferrari, E Neri, D Regge - European radiology, 2017 - Springer
Objectives To assess the opinion on structured reporting (SR) and its usage by radiologist
members of the Italian Society of Medical Radiology (SIRM) via an online survey. Methods All …

[HTML][HTML] Anatomical variations of the coeliac trunk and the mesenteric arteries evaluated with 64-row CT angiography

R Ferrari, CN Cecco, F Iafrate, P Paolantonio… - La radiologia …, 2007 - infona.pl
Purpose This study was undertaken to evaluate the accuracy of 64-row computed tomography
angiography (CTA) in the study of vascular anatomy by assessing the incidence of …

Detection and isolation of replay attacks through sensor watermarking

RMG Ferrari, AMH Teixeira - IFAC-PapersOnLine, 2017 - Elsevier
This paper addresses the detection and isolation of replay attacks on sensor measurements.
As opposed to previously proposed additive watermarking, we propose a multiplicative …

A switching multiplicative watermarking scheme for detection of stealthy cyber-attacks

RMG Ferrari, AMH Teixeira - IEEE Transactions on Automatic …, 2020 - ieeexplore.ieee.org
This article addresses the detection of stealthy attacks on sensor measurements. Inspired in
authentication schemes with weak cryptographic guarantees, we propose a watermarking …

A novel adaptive controller for robot manipulators based on active inference

C Pezzato, R Ferrari, CH Corbato - IEEE Robotics and …, 2020 - ieeexplore.ieee.org
More adaptive controllers for robot manipulators are needed, which can deal with large model
uncertainties. This letter presents a novel active inference controller (AIC) as an adaptive …

Anatomic variations of the hepatic arteries in 250 patients studied with 64-row CT angiography

CN De Cecco, R Ferrari, M Rengo, P Paolantonio… - European …, 2009 - Springer
The aim of our study was to determine the frequency of different hepatic arterial variants
identified on abdominal CT angiography (CTA) with a 64-row CT system and a high resolution …