User profiles for Harry J. Davies

Harry J Davies

Research Associate in Electrical and Electronic Engineering, Imperial College London
Verified email at imperial.ac.uk
Cited by 216

In-Ear SpO2: A Tool for Wearable, Unobtrusive Monitoring of Core Blood Oxygen Saturation

HJ Davies, I Williams, NS Peters, DP Mandic - Sensors, 2020 - mdpi.com
The non-invasive estimation of blood oxygen saturation (SpO 2 ) by pulse oximetry is of vital
importance clinically, from the detection of sleep apnea to the recent ambulatory monitoring …

The 2023 wearable photoplethysmography roadmap

…, HJ Davies, C Ding, X Ding, J Dunn… - Physiological …, 2023 - iopscience.iop.org
Photoplethysmography is a key sensing technology which is used in wearable devices such
as smartwatches and fitness trackers. Currently, photoplethysmography sensors are used to …

Wearable in-ear PPG: Detailed respiratory variations enable classification of COPD

HJ Davies, P Bachtiger, I Williams… - IEEE Transactions …, 2022 - ieeexplore.ieee.org
An ability to extract detailed spirometry-like breathing waveforms from wearable sensors
promises to greatly improve respiratory health monitoring. Photoplethysmography (PPG) has …

[HTML][HTML] Rapid extraction of respiratory waveforms from photoplethysmography: A deep corr-encoder approach

HJ Davies, DP Mandic - Biomedical Signal Processing and Control, 2023 - Elsevier
Much of the information related to breathing is contained within the photoplethysmography (PPG)
signal, through changes in venous blood flow, heart rate and stroke volume. We aim to …

Hearables: Artefact removal in Ear-EEG for continuous 24/7 monitoring

E Occhipinti, HJ Davies, G Hammour… - … Joint Conference on …, 2022 - ieeexplore.ieee.org
Ear-worn devices offer the opportunity to measure vital signals in a 24/7 fashion, without the
need of a clinician. These devices are however prone to motion artefacts, so that entire …

A deep matched filter for R-peak detection in ear-ECG

HJ Davies, G Hammour, M Zylinski, A Nassibi… - arXiv preprint arXiv …, 2023 - arxiv.org
The Ear-ECG provides a continuous Lead I electrocardiogram (ECG) by measuring the
potential difference related to heart activity using electrodes that can be embedded within …

Imaging with therapeutic acoustic wavelets–short pulses enable acoustic localization when time of arrival is combined with delay and sum

HJ Davies, SV Morse, MJ Copping… - IEEE Transactions …, 2020 - ieeexplore.ieee.org
Passive acoustic mapping (PAM) is an algorithm that reconstructs the location of acoustic
sources using an array of receivers. This technique can monitor therapeutic ultrasound …

In-ear spo2 for classification of cognitive workload

HJ Davies, I Williams, G Hammour, M Yarici… - arXiv preprint arXiv …, 2021 - arxiv.org
Classification of cognitive workload promises immense benefit in diverse areas ranging from
driver safety to augmenting human capability through closed loop brain computer interface. …

A transition probability based classification model for enhanced N1 sleep stage identification during automatic sleep stage scoring

HJ Davies, T Nakamura… - 2019 41st Annual …, 2019 - ieeexplore.ieee.org
Automatic sleep staging provides a cheaper, faster and more accessible alternative for
evaluating sleep patterns and quality compared with manual hypnogram scoring performed by a …

The Deep-Match Framework: R-Peak Detection in Ear-ECG

HJ Davies, G Hammour, M Zylinski… - IEEE Transactions …, 2024 - ieeexplore.ieee.org
The Ear-ECG provides a continuous Lead I like electrocardiogram (ECG) by measuring the
potential difference related to heart activity by electrodes which are embedded within …