An extended simplified reference tissue model for the quantification of dynamic PET with amphetamine challenge

Neuroimage. 2006 Nov 1;33(2):550-63. doi: 10.1016/j.neuroimage.2006.06.038. Epub 2006 Aug 21.

Abstract

Background: Equilibrium analysis to quantify dynamic positron emission tomography (PET) with bolus followed by continuous tracer infusion and acute amphetamine challenge assumes that all tissue kinetics attain steady states during pre- and post-challenge phases. Violations of this assumption may result in unreliable estimation of the amphetamine-induced percent change in the binding potential (DeltaBP%).

Method: We derived an extended simplified reference tissue model (ESRTM) for modeling tracer kinetics in the pre- and post-challenge phases. Ninety-minute [11C]raclopride PET studies with bolus injection followed by continuous tracer infusion were performed on 18 monkeys and 2 baboons. Forty minutes after the bolus injection, a single acute intravenous amphetamine administration was given of 2.0 mg/kg to monkeys and of 0.05, 0.1, 0.5, and 1.5 mg/kg to baboons. Computer simulations further evaluated and characterized the ESRTM.

Results: In monkey studies, the DeltaBP% estimated by the ESRTM was 32+/-11, whereas, the DeltaBP% obtained using the equilibrium methods was 32% to 81% lower. In baboon studies, the DeltaBP% values estimated with the ESRTM showed a linear relationship between the DeltaBP% and the natural logarithm of amphetamine dose (R2=0.96), where the DeltaBP%=10.67Ln(dose)+33.79 (0.05<or=dose in mg/kg<or=1.5). At 1.5 mg/kg amphetamine, the DeltaBP% estimates from equilibrium methods were 18% to 40% lower than those estimated by the ESRTM. Results showed that the nonsteady state of tracer kinetics produced an underestimation of the DeltaBP% from the equilibrium analysis. The accuracy of the DeltaBP% estimates from the equilibrium analysis was significantly improved by the ESRTM. The DeltaBP% estimated by the ESRTM in the study was consistent with that from previous [11C] raclopride PET with amphetamine challenge.

Conclusion: In conclusion, the ESRTM is a robust kinetic modeling approach and is proposed for the quantification of dynamic PET with acute amphetamine stimulation.

Publication types

  • Research Support, N.I.H., Extramural

MeSH terms

  • Amphetamine / pharmacology
  • Brain / anatomy & histology
  • Brain / diagnostic imaging*
  • Brain Mapping / methods*
  • Carbon Radioisotopes / pharmacokinetics*
  • Cerebellum / anatomy & histology
  • Cerebellum / diagnostic imaging
  • Cerebellum / drug effects
  • Computer Simulation
  • Corpus Striatum / anatomy & histology
  • Corpus Striatum / diagnostic imaging
  • Humans
  • Kinetics
  • Models, Neurological
  • Positron-Emission Tomography / methods*
  • Raclopride / pharmacokinetics*
  • Reference Values

Substances

  • Carbon Radioisotopes
  • Raclopride
  • Amphetamine