Abstract
Basic motion patterns and posture can be distinguished by multichannel accelerometry, as recently shown. A refinement of this method appeared to be desirable to further increase its effectiveness, especially to distinguish walking and climbing stairs, and body rotation during sleep. Recordings were made of 31 subjects, according to a standard protocol comprising 13 motions and postures. This recording was repeated three times with appropriate permutation. Five uni-axial sensors and three sites of placement (sternum with three axes, right and left thigh) were selected. A hierarchical classification strategy used a standard protocol (i. e., individual reference patterns) to distinguish subtypes of moving behaviors and posture. The analysis method of the actometer signals reliably detected 13 different postural and activity conditions (only 3.2 % misclassifications). A minimum set of sensors can be found for a given application; for example, a two-sensor configuration would clearly suffice to differentiate between four basic classes (sitting, standing, lying, moving) in ambulatory monitoring.
Article PDF
Similar content being viewed by others
References
Bouten, C. V. C., Verboeket-van de Venne, W. P. G., Westerterp, K. R., Verduin, M., &Janssen, J. D. (1996). Daily physical activity assessment: Comparison between movement registration and doubly labeled water.Journal of Applied Physiology,81, 1019–1026.
Busser, H. J. (1994). Using the piezoresistive accelerometer in posture and motion monitoring. In P. H. Veltink & R. C. van Lummel (Eds.),Dynamic analysis using body fixed sensors: Second World Congress of Biomechanics (pp. 107–109). The Hague: McRoberts.
Busser, H. J., Ott, J., van Lummel, R. C., Uiterwaal, M., &Blank, R. (1997). Ambulatory monitoring of children’s activity.Medical Engineering & Physics,19, 440–445.
Bussmann, H. (1998).Ambulatory monitoring of mobility-related activities in rehabilitation medicine. Delft: Eburon.
Bussmann, J. B. J., Tulen, J. H. M., van Herel, E. C. G., &Stam, H. J. (1998). Quantification of physical activities by means of ambulatory accelerometry: A validation study.Psychophysiology,35, 488–496.
Bussmann, J. B. J., Veltink, P. H., Martens, W. L. J., &Stam, H. J. (1994). Activity monitoring with accelerometers. In P. H. Veltink & R. C. van Lummel (Eds.),Dynamic analysis using body fixed sensors: Second World Congress of Biomechanics (pp. 13–17). The Hague: McRoberts.
Fahrenberg, J., Foerster, F., Müller, W., &Smeja, M. (1997). Assessment of posture and motion by multichannel piezoresistive accelerometer recordings.Psychophysiology,34, 607–612.
Fahrenberg, J., Müller, W., Foerster, F., &Smeja, M. (1996). A multichannel investigation of physical activity.Journal of Psychophysiology,10, 209–217.
Fahrenberg, J., &Myrtek, M. (Eds.) (1996).Ambulatory assessment: Computer-assisted psychological and psychophysiological methods in monitoring and field studies. Seattle: Hogrefe & Huber.
Foerster, F., &Smeja, M. (1999). Joint amplitude and frequency analysis of tremor activity.Electromyography & Clinical Neurophysiology,39, 11–19.
Foerster, F., Smeja, M., &Fahrenberg, J. (1999). Detection of posture and motion by accelerometry: A validation study in ambulatory monitoring.Computers & Human Behavior,15, 571–583.
Halmos, P. R. (1950).Measure theory. Princeton, NJ: Van Nostrand.
Jain, A., Martens, W. L. J., Mutz, G., Weifl, R. K., &Stephan, E. (1996). Towards a comprehensive technology for recording and analysis of multiple physiological parameters within their behavioral and environmental context. In J. Fahrenberg & M. Myrtek (Eds.),Ambulatory assessment: Computer-assisted psychological and psychophysiological methods in monitoring and field studies (pp. 215–235). Seattle: Hogrefe & Huber.
Kiani, K., Snijders, C. J., &Gelsema, E. S. (1997). Computerized analysis of daily life motor activity for ambulatory monitoring.Technology & Health Care,5, 307–318.
Martens, W. L. J. (1994). Exploring the information content and some applications of body mounted piezoresistive accelerometers. In P. H. Veltink & R. C. van Lummel (Eds.),Dynamic analysis using body fixed sensors: Second World Congress of Biomechanics (pp. 9–12). The Hague: McRoberts.
Middelkoop, H. A. M., van Dam, E. M., Smilde-van den Doel, D. A., &van Dijk, G. (1997). 45-hour continuous quintuple-site actimetry: Relations between trunk and limb movements and effects of circadian sleep-wake rhythmicity.Psychophysiology,34, 199–203.
Myrtek, M., Brügner, G., &Müller, W. (1996). Interactive monitoring and contingency analysis of emotionally induced ECG changes: Methodology and applications. In J. Fahrenberg & M. Myrtek (Eds.),Ambulatory assessment: Computer-assisted psychological and psychophysiological methods in monitoring and field studies (pp. 115–127). Seattle: Hogrefe & Huber.
Patterson, S. M., Krantz, D. S., Montgomery, L. C., Deuster, P. A., Hedges, S. M., &Nebel, L. E. (1993). Automated physical activity monitoring: Validation and comparison with physiological and self-report measures.Psychophysiology,30, 296–305.
Pickering, T. G. (1991).Ambulatory monitoring and blood pressure variability. London: Science Press.
Qian, S., &Chen, D. (1996).Joint time-frequency analysis: Method and application. Upper Saddle River, NJ: Prentice-Hall.
Richardson, M. T., Leon, A. S., Jacobs, D. R., Ainsworth, B. E., &Serfass, R. (1995). Ability of the Caltrac accelerometer to assess daily physical activity levels.Journal of Cardiopulmonary Rehabilitation,15, 107–113.
Smeja, M., Foerster, F., Fuchs, G., Emmans, D., Hornig, A., &Fahrenberg, J. (1999). 24 hr assessment of tremor activity and posture in Parkinson’s disease by multichannel accelerometry.Journal of Psychophysiology,13, 245–256.
Tryon, W. W. (1991).Activity measurement in psychology and medicine. New York: Plenum.
Tuomisto, M. T., Johnston, D.W., &Schmidt, T. F. H. (1996). The ambulatory measurement of posture, thigh acceleration, and muscle tension and their relationship to heart rate.Psychophysiology,33, 409–415.
van de Weijer, J. G. W., Smits, M. G., de Haan, A. F., &van Lummel, R. C. (1994). Detecting sleeping postures by accelerometry. The development of a bedrest monitor. In P. H. Veltink & R. C. van Lummel (Eds.),Dynamic analysis using body fixed sensors: Second World Congress of Biomechanics (pp. 23–25). The Hague: McRoberts.
van Someren, E. J., Vonk, B. F., Thijssen, W. A., Speelman, J. D., Schuurman, P. R., Mirmiran, M., &Swaab, D. F. (1998). A new actigraph for long-term registration of the duration and intensity of tremor and movement.IEEE Transactions on Biomedical Engineering,45, 386–395.
Veltink, P. H., Bussmann, H. B. J., de Vries, W., Martens, W. L. C., &van Lummel, R. C. (1996). Detection of postures and movements using uni-axial accelerometers.IEEE Rehabilitation Engineering,4, 375–385.
Veltink, P. H., &van Lummel, R. C. (Eds.) (1994).Dynamic analysis using body fixed sensors: Second World Congress of Biomechanics. The Hague: McRoberts.
Walker, D. J., Heslop, P. S., Plummer, C. J., Essex, T., &Chandler, S. (1997). A continuous patient activity monitor: Validation and relation to disability.Physiological Measurement,18, 49–59.
Author information
Authors and Affiliations
Corresponding author
Additional information
This research was supported by the Deutsche Forschungsgemeinschaft Fa 54/14. We thank Manfred Smeja, Uli Ebner, and Tanja Thielgen, postgraduate and graduate students, for their assistance in data acquisition, and Marcus Cheetham for improving the English version of this article.
Rights and permissions
About this article
Cite this article
Foerster, F., Fahrenberg, J. Motion pattern and posture: Correctly assessed by calibrated accelerometers. Behavior Research Methods, Instruments, & Computers 32, 450–457 (2000). https://doi.org/10.3758/BF03200815
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.3758/BF03200815