Detection of Streptococcus pneumoniae from Different Types of Nasopharyngeal Swabs in Children

  • Felix S. Dube ,

    fdube82@gmail.com

    Affiliation Division of Medical Microbiology, Faculty of Health Sciences, University of Cape Town, Cape Town, South Africa

  • Mamadou Kaba,

    Affiliations Division of Medical Microbiology, Faculty of Health Sciences, University of Cape Town, Cape Town, South Africa, Institute for Infectious Diseases and Molecular Medicine, Faculty of Health Sciences, University of Cape Town, Cape Town, South Africa

  • Elizabeth Whittaker,

    Affiliations Academic Department of Paediatrics, Wright–Fleming Institute, Imperial College London, St Mary's Campus, London, United Kingdom, Department of Paediatrics and Child Health, University of Cape Town, South Africa, Red Cross War Memorial Children's Hospital, Cape Town, South Africa

  • Heather J. Zar,

    Affiliations Department of Paediatrics and Child Health, University of Cape Town, South Africa, Red Cross War Memorial Children's Hospital, Cape Town, South Africa

  • Mark P. Nicol

    Affiliations Division of Medical Microbiology, Faculty of Health Sciences, University of Cape Town, Cape Town, South Africa, Institute for Infectious Diseases and Molecular Medicine, Faculty of Health Sciences, University of Cape Town, Cape Town, South Africa, National Health Laboratory Service, Groote Schuur Hospital, Cape Town, South Africa

Abstract

Background

A better understanding of the epidemiology of nasopharyngeal carriage of Streptococcus pneumoniae is important to assess the impact of vaccination and the pathogenesis of pneumococcal disease. We compared the recovery of S. pneumoniae from nylon flocked, Dacron and rayon swabs.

Methods

The recovery of S. pneumoniae from mocked specimens using flocked, Dacron and rayon swabs were compared by culture. The yield from paired nasopharyngeal (NP) samples obtained from healthy children sampled with flocked and Dacron swabs was also determined using culture and lytA-targeted real-time polymerase chain reaction (qPCR).

Results

Using mock specimen, the percentage recovery of S. pneumoniae ATCC 49619 (serotype 19F) strain from the flocked swabs was 100%, while it was 41% from Dacron swabs and 7% from rayon swabs. Similar results were observed for S. pneumoniae serotypes 1 and 5. S. pneumoniae was cultured from 18 of 42 (43%) paired NP samples from the healthy children (median age 8 [interquartile range (IQR) 5–16] months). The median number of colony-forming units (CFU) recovered from flocked swabs was two-fold higher (8.8×104 CFU/mL [IQR, 2.0×102 – 4.0×105 CFU/mL]) than Dacron swabs (3.7×104 CFU/mL [IQR, 4.0×102–3.2×105 CFU/mL], p = 0.17). Using lytA-targeted qPCR from paired NP samples, the median copy number of S. pneumoniae detected from flocked swabs was significantly higher than from Dacron swabs (3.0×105 genome copies/mL [IQR, 1.3×102−1.8×106] vs. 9.3×104 genome copies/mL [IQR, 7.0×101−1.1×106]; p = 0.005).

Conclusion

Flocked swabs released more S. pneumoniae compared to both Dacron and rayon swabs from mock specimens. Similarly, higher bacterial loads were detected by qPCR from flocked swabs compared with Dacron swabs from healthy children.

Introduction

Streptococcus pneumoniae is the leading bacterial cause of childhood pneumonia worldwide [1], [2]. S. pneumoniae colonizes the nasopharynx of many healthy young children and only causes pneumonia in a small proportion of those colonized [3][6]. The timing of acquisition, intensity of colonization and interaction of S. pneumoniae with other respiratory pathogens are likely to be key determinants for progression to pneumonia [7][10]. Since nasopharyngeal (NP) colonization by S. pneumoniae is key to understanding the pathogenesis of pneumococcal disease and is increasingly used as an endpoint for pneumococcal vaccine studies, it is important to establish the optimal strategy for recovery of S. pneumoniae from NP specimens. Sampling of the NP may be achieved using an NP swab or aspirate. NP swabs are preferred as the procedure is simpler, quicker and better tolerated by children. The ideal swab would be highly absorbent, maintain the viability of microorganisms present, release most of the specimen material into culture broth or transport medium and not inhibit culture or nucleic acid amplification.

Traditionally used swabs, such as Dacron and rayon swabs are constructed by winding the respective fibres onto the tip of the swab shaft. This swab design may potentially trap a large proportion of clinical material in the fibre matrix, potentially reducing the recovery of microorganisms. Flocked swabs are constructed by electrostatically attaching flocked fibres onto their nylon-tipped surfaces which potentially results in improved specimen collection and more efficient release of specimen material [11]. In addition, flocked swabs have been used for the detection of respiratory viruses [12][16], S.pneumoniae [17][19], and other bacteria [20][22].

There are limited data comparing the recovery of S. pneumoniae using different types of swabs [22]. Only one study has compared the recovery of S. pneumoniae by culture and nucleic acid amplification from Dacron, calcium alginate and rayon swabs [23]. No published study has compared the more recently available flocked swabs (Copan Italia, Brescia, Italy) with other swab types for the recovery of S. pneumoniae. Therefore, the aim of the present study was to compare the yield from different types of swabs using culture and nucleic acid-based detection methods.

Materials and Methods

Pneumococcal recovery from mockspecimens using flocked, Dacron, and rayon NP swabs

American Type Culture Collection (ATCC 49619) strain of S. pneumoniae (serotype 19F) as well as clinical isolates of S. pneumoniae serotypes 1 and 5 (donation from the Respiratory and Meningeal Pathogens Research Unit, National Institute for Communicable Diseases, National Health Laboratory Service, Johannesburg, South Africa) were sub-cultured onto Columbia blood agar base with 2% agar, 5% horse blood and 4 µg/mL gentamicin (CAG) (Greenpoint Media Laboratory, National Health Laboratory Service, Cape Town, South Africa) and incubated at 37°C in 5% CO2 overnight. The resulting colonies were then inoculated into 10 mL Todd-Hewitt broth and incubated at 37°C in 5% CO2 for 3 hours to an optical density of 0.5 at 492 nm (which corresponds to an exponential phase of approximately 1.2×108 CFU/mL, as determined previously [data not shown]).

Three different types of NP swabs were compared, the flocked swab (cat. no. 516C; Copan Italia, Brescia, Italy), Dacron swab (cat. no. MW151D; Medical Wire & Equipment, Corsham, United Kingdom) and rayon swab (cat. no. 160C; Copan Italia, Brescia, Italy). Log-phase cultures of each of the S. pneumoniae strains were serially diluted (10-fold) in phosphate buffered saline (PBS). For each of the S. pneumoniae strains, triplicate aliquots (20 µL) of the 10−2−10−4 dilutions were dispensed into 200 µL tubes. A single swab of each type was briefly placed into each of the triplicate aliquots of the above mentioned dilutions series until the inoculum was absorbed into the swab. This was performed for all swab types tested. The swabs were allowed to stand at room temperature for 10 minutes before transferring them into 1 mL of skim milk-tryptone-glucose-glycerol (STGG) transport medium. The composition of the STGG medium used in this study is based on the study published by O′Brien et al. [24]. After 30 minutes, the vials containing STGG and swabs were vortexed for 15 seconds, and 20 µL was inoculated onto CAG media and incubated at 37°C in 5% CO2 overnight. In order to simulate 100% release of S. pneumoniae strains (referred to as control) from an inoculated swab into the STGG media, 20 µL aliquots of the 10−2−10−4 dilutions were directly inoculated into 1 mL vials of STGG. Thereafter, 20 µL aliquots were directly inoculated onto CAG media. The plates were incubated at 37°C in 5% CO2 overnight and colony-forming units (CFU) determined. The percentage of S. pneumoniae recovery was calculated as the proportion of the mean CFU recovered from each swab type divided by the control (simulated 100% CFU recovered). The experiment was repeated on three different days.

Pneumococcal recovery from healthy children using flocked and Dacron NP swabs

The in-vitro study was subsequently complemented by an evaluation of the recovery of S. pneumoniae from flocked and Dacron NP swabs from healthy children. Rayon swabs were not included in this comparison as previous in-vitro studies, including our own findings (below) had demonstrated that flocked and Dacron swabs were better than rayon swabs for S. pneumoniae release [12], [20], [25][27], and there are practical difficulties in performing a 3-way comparison. Consecutive healthy children undergoing elective surgery at Red Cross War Memorial Children's Hospital were enrolled. Swabs were obtained by a trained research nurse using a standardised procedure [28]. Paired NP swabs were obtained from each child from separate nostrils. A flocked swab was used to obtain a specimen from one nostril and a Dacron swab from the other nostril. The order of sampling was randomized. Written informed consent was obtained from a parent or legal guardian. The study was approved by the Human Research Ethics Committee of the Faculty of Health Sciences, University of Cape Town (HREC ref: 062/2011).

Following sampling, swabs were immediately placed into 1 mL of STGG, transported on ice to the laboratory and frozen at −80°C for later batch processing. After thawing, STGG samples were vortexed for 15 seconds to disperse organisms from the swab. A 10 µL aliquot was then inoculated onto CAG media and incubated at 37°C in 5% CO2 overnight.

Total nucleic acid extraction from flocked and Dacron NP swabs from healthy children

The STGG aliquots were thawed to room temperature (22°C) and vortexed for 15 seconds. Thereafter, 300 µL of each sample was subjected to automated total nucleic acid extraction on the QIAsymphony SP instrument (Qiagen, Hilden, Germany) using the QIAsymphony® Virus/Bacteria mini kit (cat.no. 931036) according to the manufacturer's instructions. Total nucleic acid was eluted in 60 µL elution buffer and stored at −20°C until processing.

Identification of S. pneumoniae using lytA-targeted real-time PCR from NP samples collected in healthy children

A quantitative real-time PCR (qPCR) assay for the detection of the S. pneumoniae autolysin-encoding gene (lytA) was performed to determine bacterial load recovered from either flocked or Dacron swabs collected from healthy children. Primers and probe used were those previously published by Carvalho et al. [29], and have been shown to be specific for S. pneumoniae detection [30]. The reaction mix contained 2.5 µL genomic DNA in a total reaction volume of 12.5 µL containing; 1×TaqMan® gene expression mastermix (Applied Biosystems, California, United States of America), 200 nM for each primer and probe. PCR amplification was performed on the Bio-Rad CFX96 Touch™ Real-Time PCR amplification system (Bio-Rad Laboratories, Hercules, CA, United States of America). The thermal cycling conditions consisted of an initial hot start of 50°C for 2 minutes, denaturation at 95°C for 10 minutes, followed by 40 amplification cycles of 95°C for 15 seconds, 60°C for 1 minute. The lowest limit of detection of the qPCR assay was 10 copies/mL as determined by inspection of a standard curve (10-fold serial dilution of S. pneumoniae ATCC 49619 strain genomic DNA). The quantification cycle (Cq) value at the detection limit point was 36. A positive (S. pneumoniae ATCC 49619) and non-template control (sterile water) were included in each run. Results below the lowest limit of detection were considered negative.

Statistical analysis

Statistical analysis was performed using GraphPad Prism version 6.01 (GraphPad Software Inc, California, United States of America) and STATA software version 11.0 (Stata Corporation, Texas, United States of America). For normally distributed data, unpaired student t-test was used to compare the means of two groups. Wilcoxon rank-sum test was used to assess the median between two groups when the data was not normally distributed. Analysis of variance was performed to determine whether the mean CFU of S. pneumoniae recovered was different within triplicates of each swab type or across S. pneumoniae strains when the experiments were repeated on three different days. A p value less than 0.05 was considered as significant.

Results

Pneumococcal recovery from mock specimens by culture

Overall, there was a significant difference in the mean CFU of S. pneumoniae recovered across all the swab types (p<0.001) and across the three S. pneumoniae strains (p = 0.012) tested. There was no statistical differences in the mean CFU of S. pneumoniae recovered within triplicates of each swab type performed on the same day (p = 0.85) or when the experiments were repeated on three different days (p = 0.89), suggesting that the experiments were reproducible. As such, the S. pneumoniae CFU recovered from triplicates of each swab type and on three different days were pooled.

The percentage recovery of S. pneumoniae ATCC 49619 (Serotype 19F) strain from flocked swabs was 100%, while it was 41% from Dacron swabs and 7% from rayon swabs (Table 1). The mean number CFU of S. pneumoniae recovered from the ATCC 49619 (serotype 19F) strain using flocked swabs was higher when compared with Dacron (18×107 CFU/mL vs. 7.3×107 CFU/mL, p<0.001) and rayon swabs (18×107 CFU/mL vs. 1.3×107 CFU/mL, p<0.001) (Fig. 1A). Dacron swabs released significantly more S. pneumoniae (ATCC 49619) than rayon swabs (7.3×107 CFU/mL vs. 1.3×107 CFU/mL, p<0.001). Similar results were also observed for S. pneumoniae serotypes 1 (Fig. 1B) and 5 (Fig. 1C).

thumbnail
Figure 1. Recovery of Streptococcus pneumoniae from mock specimens using flocked, Dacron and rayon swabs.

The data is presented as the pooled mean CFU recovered from 9 replicate of each swab type using S.pneumoniae serotype 19F (Fig 1A), serotype 1 (Fig 1B) or serotype 5 (Fig 1C). An unpaired student t-test was used for statistical comparisons.

https://doi.org/10.1371/journal.pone.0068097.g001

thumbnail
Table 1. Recovery of Streptococcus pneumoniae from mock specimens using flocked, Dacron and rayon swabs.

https://doi.org/10.1371/journal.pone.0068097.t001

Pneumococcal recovery from NP samples collected from healthy children

Cultivation.

Paired (flocked and Dacron) NP samples were collected from 42 healthy children (median age 8 [IQR 5–16] months) according to the WHO S. pneumoniae carriage protocol [28]. S. pneumoniae was cultured from 18 of the 42 (43%) NP samples. In 12 of 42 (29%) participants S. pneumoniae was recovered from both flocked and Dacron swabs, whilst in four (10%) and two (5%) participants S. pneumoniae was recovered only from flocked and Dacron swabs respectively. The children from whom S. pneumoniae was recovered were younger than those from whom it was not (8 months vs. 12 months, p = 0.032). Although the median number of CFU recovered from flocked swabs was approximately two-fold higher (8.8×104 CFU/mL [IQR, 2.0×102 – 4.0×105 CFU/mL]) than that of Dacron swabs (3.7×104 CFU/mL [IQR, 4.0×102–3.2×105 CFU/mL]), this difference was not significant, p = 0.17.

Quantitative real-time PCR.

Using qPCR, S. pneumoniae was detected in 27 of the 42 (64%) NP samples overall, with similar detection rates from flocked and Dacron swabs (26 out of 42 [62%] vs. 24 out of 42 [57%]; p = 0.657). S. pneumoniae was detected in both flocked and Dacron swabs in 55% (23 out of 42) of the participants. In three participants, S. pneumoniae was detected from flocked swabs only and in one participant from Dacron swab only (p<10−3). Comparing the bacterial loads of S. pneumoniae detected by lytA qPCR from paired NP samples, the median copy number of S. pneumoniae detected from flocked swabs (3.0×105 genome copies/mL [IQR, 1.3×102−1.8×106]) was significantly higher than from Dacron swabs (9.3×104 genome copies/mL [IQR, 7.0×101−1.1×106]; p = 0.005).

The comparison of S. pneumoniae detection by culture and qPCR from NP samples collected from healthy children is summarised in Table 2. The proportion of S. pneumoniae detected by either flocked or Dacron swabs by qPCR was higher when compared to bacterial culture (64% [27/42] vs. 43% [18/42]; p = 0.049).

thumbnail
Table 2. Comparison of Streptococcus pneumoniae detection by culture and real-time PCR from healthy children.

https://doi.org/10.1371/journal.pone.0068097.t002

Discussion

A report from World Health Organisation (WHO) working group [28] and unpublished data from the US Centers for Disease Control and Prevention (CDC) [31] suggest the use of either Dacron or calcium alginate swabs collected in STGG transport medium for S. pneumoniae carriage studies. The present study demonstrated that flocked swabs were better compared to both Dacron and rayon swabs for recovery of S. pneumoniae from mock specimens. In addition, Dacron swabs recovered significantly more S. pneumoniae than rayon swabs. The findings from this study are in line with what has previously been shown for other bacteria [11], [21], [32]. For instance, Verhoeven et al. showed that flocked swabs were superior to rayon swabs for the recovery of Staphylococcus aureus using culture[20]. Similarly, flocked swabs have been shown to improve the recovery of epithelial cells and viruses compared to rayon swabs [12], [13], [16]. Our finding, that Dacron swabs were better than rayon swabs for the recovery of pneumococcus is in contrast with the finding of Rubin et al. (2008), following a similar protocol [23]. In our study, we used twice the volume of medium to inoculate swabs (20 µL vs. 10 µL) used by Rubin et al in their in-vitro assay [23].

Whilst we found no significant statistical difference between flocked and Dacron swabs for recovery of S. pneumoniae by bacterial culture from NP samples collected in children (p = 0.17), significantly greater bacterial load of S. pneumoniae was detected by qPCR from flocked swabs compared to Dacron swabs (p = 0.005). The importance of bacterial load has been recently demonstrated by Albrich et al. showing that the density of NP colonization by S. pneumoniae was higher in patients with pneumococcal community-acquired pneumonia compared to control patients using Dacron swabs for both culture and lytA-targeted qPCR [33]. Further, using the PCR-based methods, the severity of pneumonia caused by S. pneumoniae has been shown to be associated with an increased bacterial load in two independent studies using serum/blood samples [8], [34].

The present study did not assess the ability of each swab type tested for collecting other types of specimen, such as sampling of solid surfaces, vaginal and anal specimen collection. However, other studies have shown that flocked swabs are more efficient in recovery of bacteria (e.g. Bacillus atrophaeus spores, S. aureus, Enterococcus hirae) from solid surfaces [11], [32], [35], [36]. In addition, flocked swabs have been shown to collect similar or slightly more cells from anal specimen than Dacron swabs [37]. It has been shown that the DNA extraction methods may influence the DNA recovery from both cotton and flocked swabs used for the collection of DNA from saliva stains [38]. Therefore, in order to assess whether the observed high bacterial load in this study from flocked swabs is not inherent to the DNA extraction method, studies using different nucleic acid extraction methods are warranted.

In summary, our findings suggest that flocked swabs may offer an improved opportunity for recovery and detection of S. pneumoniae from NP swabs. Importantly, flocked swabs are increasingly used for NP sampling for detection of respiratory viruses by nucleic acid amplification [13], [15], [39], [40]. The use of a single swab type for both virological and bacterial studies would simplify specimen collection protocols [27].

Acknowledgments

We thank the clinical research staff for collection of samples and the children and parents for participating in the study. We further wish to thank Eliya Madikane, Samantha Africa and Sandra Piennar for their technical assistance. We also thank Henri Carrara (School of Public Health and Family medicine, University of Cape Town, South Africa) for the statistical review of this study.

Author Contributions

Conceived and designed the experiments: FD MN MK. Performed the experiments: FD EW. Analyzed the data: FD MK MN HZ EW. Contributed reagents/materials/analysis tools: MN HZ. Wrote the paper: FD MK EW HZ MN.

References

  1. 1. Rudan I, Boschi-Pinto C, Biloglav Z, Mulholland K, Campbell H (2008) Epidemiology and etiology of childhood pneumonia. Bull World Health Organ 86: 408–416.
  2. 2. Black RE, Cousens S, Johnson HL, Lawn JE, Rudan I, et al. (2010) Global, regional, and national causes of child mortality in 2008: a systematic analysis. Lancet 375: 1969–1987.
  3. 3. Bogaert D, Groot R De, Hermans PWM, De Groot R (2004) Streptococcus pneumoniae colonisation: the key to pneumococcal disease. Lancet Infect Dis 4: 144–154.
  4. 4. Coles CL, Sherchand JB, Khatry SK, Katz J, Leclerq SC, et al. (2009) Nasopharyngeal carriage of S. pneumoniae among young children in rural Nepal. Trop Med Int Health 14: 1025–1033.
  5. 5. Antonio M, Dada-adegbola H, Biney E, Awine T, Callaghan JO, et al. (2008) Molecular epidemiology of pneumococci obtained from Gambian children aged 2 – 29 months with invasive pneumococcal disease during a trial of a 9-valent pneumococcal conjugate vaccine. BMC Infect Dis 10: 1–10.
  6. 6. Hill PC, Akisanya A, Sankareh K, Cheung YB, Saaka M, et al. (2006) Nasopharyngeal carriage of Streptococcus pneumoniae in Gambian villagers. Clin Infect Dis 43: 673–679.
  7. 7. Hausdorff WP, Bryant J, Paradiso PR, Siber GR (2000) Which pneumococcal serogroups cause the most invasive disease: implications for conjugate vaccine formulation and use, part I. Clin Infect Dis 30: 100–121.
  8. 8. Rello J, Lisboa T, Lujan M, Gallego M, Kee C, et al. (2009) Severity of pneumococcal pneumonia associated with genomic bacterial load. Chest 136: 832–840.
  9. 9. Syrjänen RK, Kilpi TM, Kaijalainen TH, Herva EE, Takala a K (2001) Nasopharyngeal carriage of Streptococcus pneumoniae in Finnish children younger than 2 years old. J Infect Dis 184: 451–459.
  10. 10. Faden H, Duffy L, Wasielewski R, Wolf J, Krystofik D, et al. (1997) Relationship between nasopharyngeal colonization and the development of otitis media in children. J Infect Dis 175: 1440–1445.
  11. 11. Dalmaso G, Bini M, Paroni R Ferrari M (2008) Qualification of high-recovery, flocked swabs as compared to traditional rayon swabs for microbiological environmental monitoring of surfaces. PDA J Pharm Sci Technol 62: 191–199.
  12. 12. Daley P, Castriciano S, Chernesky M, Smieja M (2006) Comparison of flocked and rayon swabs for collection of respiratory epithelial cells from uninfected volunteers and symptomatic patients. J Clin Microbiol 44: 2265–2267.
  13. 13. Hernes SS, Quarsten H, Hagen E, Lyngroth AL, Pripp AH, et al. (2011) Swabbing for respiratory viral infections in older patients: a comparison of rayon and nylon flocked swabs. Eur J Clin Microbiol Infect Dis 30: 159–165.
  14. 14. Ohrmalm L, Wong M, Rotzén-Östlund M, Norbeck O, Broliden K, et al. (2010) Flocked nasal swab versus nasopharyngeal aspirate for detection of respiratory tract viruses in immunocompromised adults: a matched comparative study. BMC Infect Dis 10: 340.
  15. 15. Debyle C, Bulkow L, Miernyk K, Chikoyak L, Hummel KB, et al. (2012) Comparison of nasopharyngeal flocked swabs and nasopharyngeal wash collection methods for respiratory virus detection in hospitalized children using real-time polymerase chain reaction. J Virol Methods 185: 89–93.
  16. 16. Abu-Diab A, Azzeh M, Ghneim R, Ghneim R, Zoughbi M, et al. (2008) Comparison between pernasal flocked swabs and nasopharyngeal aspirates for detection of common respiratory viruses in samples from children. J Clin Microbiol 46: 2414–417.
  17. 17. Sharma D, Baughman W, Holst A, Thomas S, Jackson D, et al. (2013) Pneumococcal carriage and invasive disease in children before introduction of the 13-valent conjugate vaccine: comparison with the era before 7-valent conjugate vaccine. Pediatr Infect Dis J 32: e45–53.
  18. 18. van den Bergh MR, Bogaert D, Dun L, Vons J, Chu ML, et al. (2012) Alternative sampling methods for detecting bacterial pathogens in children with upper respiratory tract infections. J Clin Microbiol 50: 4134–4137.
  19. 19. Miernyk K, Debyle C, Harker-Jones M, Hummel KB, Hennessy T, et al. (2011) Serotyping of Streptococcus pneumoniae isolates from nasopharyngeal samples: use of an algorithm combining microbiologic, serologic, and sequential multiplex PCR techniques. J Clin Microbiol 49: 3209–3214.
  20. 20. Verhoeven P, Grattard F, Carricajo A, Pozzetto B, Berthelot P (2010) Better detection of Staphylococcus aureus nasal carriage by use of nylon flocked swabs. J Clin Microbiol 48: 4242–4244.
  21. 21. Van Horn KG, Audette CD, Tucker KA, Sebeck D (2008) Comparison of 3 swab transport systems for direct release and recovery of aerobic and anaerobic bacteria. Diagn Microbiol Infect Dis 62: 471–473.
  22. 22. Van Horn KG, Audette CD, Sebeck D, Tucker KA (2008) Comparison of the Copan ESwab system with two Amies agar swab transport systems for maintenance of microorganism viability. J Clin Microbiol 46: 1655–1658.
  23. 23. Rubin LG, Rizvi A, Baer A (2008) Effect of swab composition and use of swabs versus swab-containing skim milk-tryptone-glucose-glycerol (STGG) on culture- or PCR-based detection of Streptococcus pneumoniae in simulated and clinical respiratory specimens in STGG transport medium. J Clin Microbiol 46: 2635–2640.
  24. 24. O′Brien KL, Bronsdon MA, Dagan R, Yagupsky P, Janco J, et al. (2001) Evaluation of a medium (STGG) for transport and optimal recovery of Streptococcus pneumoniae from nasopharyngeal secretions collected during field studies. J Clin Microbiol 39: 1021–1024.
  25. 25. De Silva S, Wood G, Quek T, Parrott C, Bennett CM (2010) Comparison of flocked and rayon swabs for detection of nasal carriage of Staphylococcus aureus among pathology staff members. J Clin Microbiol 48: 2963–2964.
  26. 26. Drake C, Barenfanger J, Lawhorn J, Verhulst S (2005) Comparison of Easy-Flow Copan Liquid Stuart's and Starplex swab transport systems for recovery of fastidious aerobic bacteria. J Clin Microbiol: 3–6.
  27. 27. Turner P, Po L, Turner C, Goldblatt D, Nosten F (2011) Detection of respiratory viruses by PCR assay of nasopharyngeal swabs stored in skim milk-tryptone-glucose-glycerol transport medium. J Clin Microbiol 49: 2311–2313.
  28. 28. O′Brien KL, Nohynek H (2003) Report from a WHO Working Group: standard method for detecting upper respiratory carriage of Streptococcus pneumoniae. Pediatr Infect Dis J 22: e1–11.
  29. 29. Carvalho Mda G, Tondella ML, McCaustland K, Weidlich L, McGee L, et al. (2007) Evaluation and improvement of real-time PCR assays targeting lytA, ply, and psaA genes for detection of pneumococcal DNA. J Clin Microbiol 45: 2460–2466.
  30. 30. Greve T, Møller JK (2012) Accuracy of using the lytA gene to distinguish Streptococcus pneumoniae from related species. J Med Microbiol 61: 478–482.
  31. 31. CDC (http://www.cdc.gov/ncidod/biotech/files/pcr-pneumo-carriage-March2010. Accessed 15 February 2013) Streptococcus pneumoniae carriage study protocol.
  32. 32. Hedin G, Rynbäck J, Loré B (2010) New technique to take samples from environmental surfaces using flocked nylon swabs. J Hosp Infect 75: 314–317.
  33. 33. Albrich WC, Madhi SA, Adrian PV, Van Niekerk N, Mareletsi T, et al. (2012) Use of a rapid test of pneumococcal colonization density to diagnose pneumococcal pneumonia. Clin Infect Dis 54: 601–609.
  34. 34. Werno AM, Anderson TP, Murdoch DR (2012) Association between pneumococcal load and disease severity in adults with pneumonia. J Med Microbiol 61: 1129–1135.
  35. 35. Probst A, Facius R, Wirth R, Moissl-Eichinger C (2010) Validation of a nylon-flocked-swab protocol for efficient recovery of bacterial spores from smooth and rough surfaces. Appl Environ Microbiol 76: 5148–5158.
  36. 36. Probst A, Facius R, Wirth R, Wolf M, Moissl-Eichinger C (2011) Recovery of bacillus spore contaminants from rough surfaces: a challenge to space mission cleanliness control. Appl Environ Microbiol 77: 1628–1637.
  37. 37. Gage JC, Ghosh A, Borgonovo S, Follansbee S, Wentzensen N, et al. (2011) A comparison of dacron versus Flocked nylon swabs for anal cytology specimen collection. Acta Cytol 55: 364–367.
  38. 38. Brownlow RJ, Dagnall KE, Ames CE (2012) A comparison of DNA collection and retrieval from two swab types (cotton and nylon flocked swab) when processed using three QIAGEN extraction methods. J Forensic Sci 57: 713–717.
  39. 39. Esposito S, Molteni CG, Daleno C, Valzano A, Cesati L, et al.. (2010) Comparison of nasopharyngeal nylon flocked swabs with universal transport medium and rayon-bud swabs with a sponge reservoir of viral transport medium in the diagnosis of paediatric influenza. J Med Microbiol: 96–99.
  40. 40. Smieja M, Castriciano S, Carruthers S, So G, Chong S, et al. (2010) Development and evaluation of a flocked nasal midturbinate swab for self-collection in respiratory virus infection diagnostic testing. J Clin Microbiol 48: 3340–3342.
  41. 41. Leung MH, Bryson K, Freystatter K, Pichon B, Edwards G, et al. (2012) Sequetyping: Serotyping Streptococcus pneumoniae by a Single PCR Sequencing Strategy. J Clin Microbiol 50: 2419–2427.