Skip to main content
Log in

Bispectral Index (BIS) and Burst Suppression: Revealing a Part of the BIS Algorithm

  • Published:
Journal of Clinical Monitoring and Computing Aims and scope Submit manuscript

Abstract

Objective. The bispectral index (BIS) is a complex EEG parameter which integrates several disparate descriptors of the EEG into a single variable. One of the subparameters incorporated in the BIS is the suppression ratio, quantifying the percentage of suppression during burst suppression pattern. The exact algorithm used to synthetize the information to the BIS value is unpublished and still unknown. This study provides insight into the integration of the suppression ratio into the BIS algorithm. Methods. EEG data of 10 healthy volunteers during propofol infusion were analyzed. Propofol concentrations were ramped up to 4 predetermined concentrations (1, 2, 3, 4, 6, 8, 9, or 12 µg/ml) using a computer controlled infusion pump (STANPUMP). EEG recordings were performed with an Aspect A-1000 EEG monitor (Version 3.22). The relationship of the processed EEG variables bispectral index and suppression ratio, calculated by the Aspect A-1000 monitor, was analyzed. Results. Up to 40% suppression ratio the average BIS values remained constant regardless of suppression ratios (r= 0.13). Beyond a suppression ratio of 40%, BIS and suppression ratio were invariably linearly correlated (r= −1). At a suppression ratio ≥ 40% the BIS value could be calculated as BIS = 50 – suppression ratio/2. Conclusions. Suppression ratio values > 40% are linearly correlated with BIS values from 30 to 0. An increasing anesthetic drug effect resulting in an increase of the duration of suppression to a suppression ratio up to 40% is not adequately reflected by the BIS value.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

REFERENCES

  1. Rampil IJ. A primer for EEG signal processing in anesthesia. Anesthesiology 1998; 89: 980–1002

    Article  PubMed  CAS  Google Scholar 

  2. Song D, Joshi GP, White PF. Titration of volatile anesthetics using bispectral index facilitates recovery after ambulatory anesthesia. Anesthesiology 1997; 87: 842–848

    Article  PubMed  CAS  Google Scholar 

  3. Billard V, Gambus PL, Chamoun N, Stanski DR, Shafer SL. A comparison of spectral edge, delta power, and bispectral index as EEG measures of alfentanil, propofol, and midazolam drug effect. Clin Pharmacol Ther 1997; 61: 45–58

    Article  PubMed  CAS  Google Scholar 

  4. Bruhn J, Bouillon TW, Shafer SL. Electromyographic activity falsely elevates the bispectral index. Anesthesiology 2000; 92: 1485–1487

    Article  PubMed  CAS  Google Scholar 

  5. Detsch O, Schneider G, Kochs E, Hapfelmeier G, Werner C. Increasing isoflurane concentration may cause paradoxical increases in the EEG bispectral index in surgical patients. Br J Anaesth 2000; 84: 33–37

    PubMed  CAS  Google Scholar 

  6. Guignard B, Chauvin M. Bispectral index increases and decreases are not always signs of inadequate anesthesia. Anesthesiology 2000; 92: 903

    Article  PubMed  CAS  Google Scholar 

  7. Schnider TW, Luginbuhl M, Petersen-Felix S, Mathis J. Unreasonably low bispectral index values in a volunteer with genetically determined low voltage electroencephalographic signal. Anesthesiology 1998; 89: 1607–1608

    Article  PubMed  CAS  Google Scholar 

  8. Glass PS, Bloom M, Kearse L, Rosow C, Sebel P, Manberg P. Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in healthy volunteers. Anesthesiology 1997; 86: 836–847

    Article  PubMed  CAS  Google Scholar 

  9. Shafer SL and Gregg KM. Algorithms to rapidly achieve and maintain stable drug concentrations at the site of drug effect with a computer-controlled infusion pump. J Pharmacokinet Biopharm 1992; 20: 147–169

    Article  PubMed  CAS  Google Scholar 

  10. Schnider TW, Minto CF, Gambus PL, Andresen C, Goodale DB, Shafer SL, Youngs EJ. The influence of method of administration and covariates on the pharmacokinetics of propofol in adult volunteers. Anesthesiology 1998; 88: 1170–1182

    Article  PubMed  CAS  Google Scholar 

  11. Rampil IJ, Laster MJ. No correlation between quantitative electroencephalographic measurements and movement responses to noxious stimuli during isoflurane anesthesia in rats. Anesthesiology 1992; 77: 920–925

    PubMed  CAS  Google Scholar 

  12. International Federations of Societies of Electroencephalography and Clinical Neuro-physiology: Recommendations for the practice of clinical neurophysiology. Amsterdam, Elsevier, 1983, p. 13

    Google Scholar 

  13. Thomsen CE and Prior PF. Quantitative EEG assessment of anaesthetic depth: Comparative study of methodology. Br J Anaesth 1996; 77: 172–178

    PubMed  CAS  Google Scholar 

  14. Rampil IJ, Lockhart SH, Eger EI II, Yasuda N, Weiskopf RB, Cahalan MK. The electroencephalographic effects of desflurane in humans. Anesthesiology 1991; 74: 434–439

    Article  PubMed  CAS  Google Scholar 

  15. Bruhn J, Röpcke H, Rehberg B, Bouillon T, Hoeft A. EEG approximate entropy correctly classifies the occurrence of burst suppression pattern as increasing anesthetic drug effect. Anesthesiology 2000; 93: 981–985

    Article  PubMed  CAS  Google Scholar 

  16. Bruhn J, Bouillon TW, Shafer SL. Onset of propofol-induced burst suppression may be correctly detected as deepening of anaesthesia by approximate entropy but not by the bispectral index. Brit J Anaesth 2001; 87: 505–507

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Bruhn, J., Bouillon, T.W. & Shafer, S.L. Bispectral Index (BIS) and Burst Suppression: Revealing a Part of the BIS Algorithm. J Clin Monit Comput 16, 593–596 (2000). https://doi.org/10.1023/A:1012216600170

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1012216600170

Navigation