Reduction in MRSA environmental contamination with a portable HEPA-filtration unit
Introduction
Handwashing by healthcare workers is thought to be the most important method of control of methicillin-resistant Staphylococcus aureus (MRSA) and other nosocomial infections.1 However, there is renewed interest in the hospital environment as a potentially important factor in cross-infection.2, 3, 4 The authors recently investigated an outbreak of Hickman-line-associated MRSA bacteraemia in a haematology day-case unit. As part of the investigations, significant MRSA contamination of the environment was found, and settle plates were positive for MRSA on a number of occasions, suggesting ongoing dispersal of MRSA into the air. At least two patients were identified as heavy shedders of MRSA, and the outbreak was controlled when a single room was designated for their further day-case treatment.
This outbreak prompted an investigation of technologies that may reduce future MRSA environmental contamination within such a setting. A number of air decontamination products have been reviewed recently by the Rapid Review Panel of the Health Protection Agency, including air filtration units and ultra-violet air disinfection units (www.hpa.org.uk/infections/topics_az/rapid_review). Two of these products have been recommended for in-use evaluations in a clinical setting (recommendation level 2), including the IQAir Cleanroom H13 portable air purification unit (Incen AG, Goldach, Switzerland). This article presents an evaluation of the effectiveness of the IQAir unit at preventing contamination of environmental surfaces with MRSA in three different clinical settings.
Section snippets
IQAir Cleanroom unit
Two IQAir Cleanroom H13 units were kindly provided by Air Science Ltd (Stroud, UK). The machines were free-standing floor units operating in recirculation mode. This portable air filtration purifier removes airborne micro-organisms by repeatedly drawing ambient room air through a pre-filter and then through a high-efficiency particulate air (HEPA) filter, with an efficiency of 99.97% for particles greater than or equal to 0.3 μm. The IQAir H13 unit's centrifugal fan can be set to run at five
Effect of air filtration on MRSA environmental contamination
Without air filtration, all three patients were confirmed to be heavy dispersers of MRSA (see Table I and Figure 1). Overall, between 80% and 100% of the settle plates were positive, with the mean number of MRSA cfu/10-h exposure/plate ranging from 4.1 to 27.7. The extent and distance of MRSA shedding without air filtration for each patient is shown graphically in Figure 1.
Air filtration at a rate of 235 m3/h (Patients A and C) and 140 m3/h (Patient B) resulted in a significant decrease in MRSA
Discussion
It is well established that MRSA contamination of the environment occurs in the vicinity of MRSA patients, and this is the principal reason for isolating patients in single rooms.5 However, relatively few reported studies have used agar settle (sedimentation) plates to assess the rate of MRSA contamination of environmental surfaces.6 This simple methodology was used in the present study to identify heavy shedders of MRSA and to measure the effect of using a portable HEPA-filtration unit on the
Acknowledgements
The authors are grateful to Air Science Ltd for providing two IQAir H13 Cleanroom units for this study. The authors would also like to thank Dr Sarah Lewis for helping with the statistical analysis.
References (16)
The role of the hospital environment in the epidemiology of multi-drug resistant bacteria
J Hosp Infect
(1999)- et al.
Evidence that hospital hygiene is important in the control of MRSA
J Hosp Infect
(2001) - et al.
Tackling contamination of the hospital environment by MRSA: a comparison between conventional terminal cleaning and hydrogen peroxide vapour decontamination
J Hosp Infect
(2004) - et al.
Evaluation of bedmaking-related airborne and surface methicillin-resistant Staphylococcus aureus contamination
J Hosp Infect
(2002) - et al.
A maternity hospital outbreak of methicillin-resistant Staphylococcus aureus
J Hosp Infect
(1991) - et al.
Ventilation grilles as a potential source of methicillin-resistant Staphylococcus aureus causing an outbreak in an orthopaedic ward at a district general hospital
J Hosp Infect
(1998) - et al.
Guideline for hand hygiene in health care settings: recommendations of the Healthcare Infection Control Practices Advisory Committee and the Hand Hygiene Task Force
Infect Control Hosp Epidemiol
(2003) Revised guidelines for the control of methicillin-resistant Staphylococcus aureus infection in hospitals
J Hosp Infect
(1998)