Short communication
Panbio antigen rapid test is reliable to diagnose SARS-CoV-2 infection in the first 7 days after the onset of symptoms

https://doi.org/10.1016/j.jcv.2020.104659Get rights and content

Highlights

  • The new antigen test is an indispensable tool in the control of the pandemic due to its adequate sensitivity and specificity.

  • The implementation of the point of care technique in primary care is feasible and has good results.

  • Results of the antigen techniques are determined by an onset of symptoms inferior to five days and a CT below 27 in PCR.

Abstract

Background

RT-qPCR is the current recommended laboratory method to diagnose SARS-CoV-2 acute infection, several factors such as requirement of special equipment, time consuming, high cost and skilled staff limit the use of these techniques. A more rapid and high-throughput method is essential.

Methods

We analyzed clinical data and nasopharyngeal samples, collected during September 2020, from patients attended at the emergency department of a secondary hospital and in two primary healthcare centers in Madrid. The performance of the Panbio™ COVID-19 AG Rapid Test Device for the detection of SARS-CoV-2 antigen was compared to RT-qPCR.

Results

255 nasopharyngeal swabs, including 150 from the emergency department and 105 from primary helthcare centers, were tested. 184 patients were symptomatic (72.1 %). Amongst the 60 positive RT-qPCR samples, 40 were detected by the rapid antigen test, given an overall sensitivity of 73.3 %. All the samples detected positive with the rapid antigen test were also positive with RT-qPCR. The median cycle threshold was 23.28 (IQR 18.5–30.16). Patients with less than seven days onset of symptoms showed a higher viral load, and sensitivity for rapid antigen test (86.5 %), compared to those with more days (sensitivity of 53.8 %)(p < 0.004).

Conclusions

The rapid antigen test evaluated in this study showed a high sensitivity and specificity in samples obtained during the first week of symptoms and with high viral loads. This assay seems to be an effective strategy for controlling the COVID-19 pandemic for the rapid identification and isolation of SARS-CoV-2 infected patients.

Abbreviations

COVID-19
Coronavirus disease 2019
CT
cycle threshold
SARS-CoV-2
severe acute respiratory syndrome coronavirus 2
NP
nucleocapsid protein
LFA
lateral flow assay
FDA
Food and Drug Administration
RT- qPCR
real-time reverse transcription polymerase chain reaction
RDT
rapid diagnostic test

Keywords

Rapid antigen detection test
SARS-CoV-2
RT-PCR
Point-of-care testing
Lateral flow assay
COVID19

Cited by (0)

1

Both authors contributed equally to this study.

View Abstract