Learning to walk with a robotic ankle exoskeleton
Introduction
Motor adaptation is critical for successful locomotion. Humans regularly modulate muscle activity during walking in response to environmental (e.g. terrain, obstacles) and neuromuscular (e.g. fatigue, muscle strength) factors. While many studies have examined human locomotor adaptation to environmental perturbations (Tokuhiro et al., 1985; Ferris and Farley, 1997; Farley et al., 1998; Ferris et al., 1998; Leroux et al., 1999; Prentice et al., 2004; Marigold and Patla, 2005; Lay et al., 2006; Maclellan and Patla, 2006), it has been more difficult to study human locomotor adaptation to controlled neuromuscular perturbations. Researchers have studied neuromuscular locomotor adaptation in animal models using botulinum toxin, nerve transections, and spinal cord lesions (Lam and Pearson, 2002). However, the invasiveness of these procedures make them unsuitable for comparable human studies.
There is a critical need to understand how humans adapt locomotor control in response to alterations in neuromuscular dynamics. Neurological insult, such as stroke, and spinal cord injury, leads to discoordinated locomotion and requires motor adaptation to restore mobility (Grasso et al., 2004; Kautz and Brown, 1998). From a clinical perspective, it is imperative to identify principles governing locomotor adaptation to perturbations disrupting muscular coordination.
We developed a novel robotic perturbation to study human locomotor adaptation to disrupted muscle coordination. The perturbation is a pneumatically powered ankle exoskeleton (Ferris et al., 2005, Ferris et al., 2006; Sawicki et al., 2006). The exoskeleton has a hinged ankle joint and an artificial pneumatic muscle providing plantar flexor torque (Fig. 1). We focused on the ankle joint because it produces more mechanical power during walking than either the hip or knee joint (Meinders et al., 1998) and is a major factor limiting mobility after neurological injury (Nadeau et al., 1999; Kim and Eng, 2003; Kim et al., 2004).
In this study, the exoskeleton was proportionally activated by the user's soleus electromyography (EMG), effectively increasing soleus muscle strength. We examined neurologically intact subjects walking with the exoskeleton on two separate days. We hypothesized that gait would be initially distorted by the exoskeleton, but that the effect would decrease with practice due to a reduction in soleus muscle recruitment. By testing subjects on two separate days, we were able to examine whether subjects stored a walking motor pattern that reflected exoskeleton dynamics.
Section snippets
Methods
Ten healthy subjects (5 male, 5 female, mean±SD, age 25.8±2.3 years and mass 75.3±12.2 kg) gave written informed consent and participated in the study. The University of Michigan Medical School Institutional Review Board approved the protocol.
We constructed a custom fit exoskeleton for the left lower limb of each subject (Fig. 1). Construction and testing of earlier prototypes of the exoskeleton have been described in detail (Ferris et al., 2005, Ferris et al., 2006; Gordon et al., 2006). The
Day 1, powered minute 1
When subjects first received additional plantar flexor torque from the powered exoskeleton, they demonstrated an immediate and substantial change in walking pattern (Fig. 3 and Movie 2 online supplement). Peak plantar flexion angle increased from −13.3±3.6° (mean±SD) during baseline to −28.3±9.1° during the first minute of powered walking. The deviation in kinematics was reflected by a significant change in ankle angle correlation common variance compared to baseline (THSD, p<0.05) (Fig. 4). In
Discussion
The findings support our hypothesis that subjects would reduce soleus recruitment when walking with a powered exoskeleton providing supplemental plantar flexion torque proportional to soleus EMG. At the end of the second walking session, subjects walked with an ankle kinematic pattern significantly different from baseline. It is possible that further training would have resulted in additional modifications to muscle activation patterns and ankle kinematics. However, linear regression of data
Acknowledgments
The authors thank Catherine Kinnaird and members of the Human Neuromechanics Laboratory for assistance in collecting and analyzing data. We also thank Ammanath Peethambaran, C.O., and the staff of the University of Michigan Orthotics and Prosthetics Center for help with designing and fabricating parts of the exoskeleton. Supported by NIH R01 NS045486.
References (37)
- et al.
Neuromuscular patterns of stereotypic hindlimb behaviors in the first two postnatal months. I. Stepping in normal kittens
Brain Research
(1988) - et al.
A stiffness-varying model of human gait
Medical Engineering and Physics
(1997) - et al.
An improved powered ankle-foot orthosis using proportional myoelectric control
Gait and Posture
(2006) - et al.
Runners adjust leg stiffness for their first step on a new running surface
Journal of Biomechanics
(1999) - et al.
Mechanical performance of artificial pneumatic muscles to power an ankle-foot orthosis
Journal of Biomechanics
(2006) - et al.
Plantarflexor weakness as a limiting factor of gait speed in stroke subjects and the compensating role of hip flexors
Clinical Biomechanics (Bristol, Avon)
(1999) - et al.
Electromyographic developmental changes in one individual from newborn stepping to mature walking
Gait and Posture
(2003) - et al.
Locomotor adaptations for changes in the slope of the walking surface
Gait and Posture
(2004) - et al.
Widespread access to predictive models in the motor system: a short review
Journal of Neural Engineering
(2005) - et al.
Evaluation of time-series data sets using the Pearson product-moment correlation coefficient
Medicine and Science in Sports and Exercise
(1994)