Major articleSelecting models for a respiratory protection program: What can we learn from the scientific literature?
Section snippets
Assessment of fit test methods
FFRs must fit properly to provide maximum protection. Mandatory procedures for assuring proper fit can be found in the OSHA Respiratory Protection standard 29 CFR 1910.134.1 The methods applicable to the N95 FFRs include qualitative fit tests using either saccharin or denatonium benzoate (Macfarlan Smith Ltd, Edinburgh, U.K.) aerosols. Adequate fit is indicated if the test subject does not detect the sweet or bitter taste of saccharin or Bitrex, respectively, while performing a series of 7
Results
Over 100 full-text articles were found using the search terms and Web sites selected. One of the authors reviewed the articles and assessed each for eligibility. No articles meeting the eligibility requirements were excluded.
Discussion
Among the performance characteristics considered in the study, only fit testing can be measured using mature and standard test methods that permit trend analysis. Fit testing is a necessary component of a respiratory protection program. Unlike fit, comfort and usability assessment are not specific respirator program requirements, and the development of standardized test methods is still emerging. However, poor comfort and usability have been identified as causes of poor compliance.2, 8, 9, 27,
Conclusions
The primary conclusion is that it is difficult to use the scientific literature directly to inform the respirator selection process. Differences in methodology, study populations, skill level of the fit tester, and inherent errors in fit testing contribute to the variation seen when looking for trends in fit test pass rates across studies. Although there does not appear to be a single best fitting FFR, several studies demonstrate that fit testing programs can be designed to successfully fit
References (40)
- et al.
Evaluation of respiratory protection programs and practices in California hospitals during the 2009-2010 H1N1 influenza pandemic
Am J Infect Control
(2013) - et al.
Health care workers' views about respirator use and features that should be included in the next generation of respirators
Am J Infect Control
(2010) - et al.
Predictive value of the user seal check in determining half-face respirator fit
J Hosp Infect
(2005) - et al.
Sensitivity and specificity of the user-seal-check in determining the fit of N95 respirators
J Hosp Infect
(2011) - et al.
Particulate face masks for protection against airborne pathogens - one size does not fit all: an observational study
Crit Care Resusc
(2010) - et al.
Implementing fit testing for N95 filtering facepiece respirators: practical information from a large cohort of hospital workers
Am J Infect Control
(2008) - et al.
What do healthcare workers think? A survey of facial protection equipment user preferences
J Hosp Infect
(2008) - et al.
B95: a new respirator for health care personnel
Am J Infect Control
(2013) - Occupational Safety and Health Administration (OSHA). Respiratory protection. 29 CFR Sect. United States Government...
- et al.
Preventing transmission of pandemic influenza and other viral respiratory diseases: personal protective equipment for healthcare workers: update 2010
(2011)
Respiratory protection programs and healthcare professionals: compliance, knowledge and perceptions
Respiratory protection against mycobacterium tuberculosis: quantitative fit test outcomes for five type N95 filtering-facepiece respirators
J Occup Environ Hyg
Safety and health program management guidelines; issuance of voluntary guidelines
Fed Regist
The use of respirators to reduce inhalation of airborne biological agents
J Occup Environ Hyg
Respirator tolerance in health care workers
JAMA
A must for NIOSH: certify fit performance of the half mask particulate respirator
J Occup Environ Hyg
Evaluation of saccharin qualitative fitting test for respirators
Am Ind Hyg Assoc J
Development of a new qualitative test for fit testing respirators
Am Ind Hyg Assoc J
Evaluation of Portacount for determining respirator fit factors, Part III: human subject tests and comparison with an aerosol photometer
J Int Soc Respir Prot Prot
Fitting characteristics of eighteen N95 filtering-facepiece respirators
J Occup Environ Hyg
Cited by (0)
Disclaimer: The findings and conclusions of this article are those of the authors and do not necessarily represent the views of the National Institute for Occupational Safety and Health. Mention of a commercial product or trade name does not constitute endorsement by the National Institute for Occupational Safety and Health.
Funding/support: This work was conducted using National Institute for Occupational Safety and Health intramural research funds.
Conflicts of interest: None to report.