Epileptic source localization with high density EEG: how many electrodes are needed?

https://doi.org/10.1016/S1388-2457(02)00337-1Get rights and content

Abstract

Objective: Electroencephalography (EEG) source reconstruction is becoming recognized as a useful technique to non-invasively localize the epileptic focus. Whereas, large array magnetoencephalography (MEG) systems are available since quite some time, application difficulties have previously prevented multichannel EEG recordings. Recently, however, EEG systems which allow for quick (10–20 min) application of, and recording from, up to 125 electrodes have become available. The purpose of the current investigation was to systematically compare the accuracy of epileptic source localization with high electrode density to that obtained with sparser electrode setups.

Methods: Interictal epileptiform activity was recorded with 123 electrodes in 14 epileptic patients undergoing presurgical evaluation. Each single epileptiform potential was down sampled to 63 and 31 electrodes, and a distributed source model (EPIFOCUS) was used to reconstruct the sources with the 3 different electrode configurations. The localization accuracy with the 3 electrode setups was then assessed, by determining the distance from the inverse solution, maximum of each single spike to the epileptogenic lesion.

Results: In 9/14 patients, the distance from the EEG source to the lesion was significantly smaller with 63 than with 31 electrodes, and increasing the number of electrodes to 123 increased this number of patients from 9 to 11. Simulations confirmed the relation between the number of electrodes and localization accuracy.

Conclusions: The results illustrate the necessity of multichannel EEG recordings for high source location accuracy in epileptic patients.

Introduction

It is now recognized that electromagnetic non-invasive source imaging may localize, precisely, primary epileptic foci with high spatial and temporal resolution. To achieve this, and to differentiate primary foci from propagated areas, a sufficient spatial sampling is needed. It has been demonstrated (Bendat and Piersol, 1986) that the sampling rate (both spatial and temporal) has to be at least 2.5 times the highest frequency component of the signal (the Nyquist frequency) in order to avoid aliasing (i.e. contamination from higher frequencies through increase of energy in lower frequency bands). As opposed to temporal sampling, spatial sampling is by definition non-continuous, which makes low pass filtering, in order to avoid aliasing, impossible (Srinivasan et al., 1998). Consequently, high spatial sampling is necessary to correctly characterize the topographical details of all frequencies as well as to avoid distortion of frequencies of interest from frequencies above the Nyquist frequency. To some extent, the problem can be diminished by the fact that the scalp acts as a spatial low pass filter, attenuating the undesired high frequency information (Nunez, 1981, Srinivasan et al., 1996). Even so, recording, for instance with the commonly used 21 electrode setup (corresponding to 6 cm inter-electrode distance), is definitely insufficient to adequately sample the spatial frequencies of around 3 cm appearing, for example, in early evoked potential components (Spitzer et al., 1989, Gevins, 1990). In a simulation study by Vanrumste et al. (2000), addressing the effect of volume conductor model errors on EEG dipole source localization, smaller localization errors were found for 53 rather than for 27 electrodes, even if this difference was quite small. Theoretical and experimental studies by Srinivasan et al. (1998) have demonstrated that a minimum of 100 electrodes is needed to properly sample the electric field from the full head surface.

In epileptic patients, electromagnetic source localization procedures are becoming an important tool in presurgical epilepsy investigations of many centers. Even though, in most EEG studies, only standard electrodes setups (between 20 and 30 electrodes) have been used, the localization precision has increased, and some groups have reported accuracy down to the sublobar level (Scherg et al., 1999, Michel et al., 1999, Fuchs et al., 1999) and the possibility to differentiate between deep and superficial temporal sources (Lantz et al., 1997, Lantz et al., 2001a). A number of investigators have used high density MEG recordings (more than 100 sensors) in epileptic patients (Paetau et al., 1999, Lamusuo et al., 1999, Scherg et al., 1999, Baumgartner et al., 2000), but only in a few studies (Herrendorf et al., 2000, Waberski et al., 2000, Gross et al., 2000) has multichannel EEG been used in epilepsy investigations, and in these cases only with 64 electrodes. To our knowledge, neither EEG source localization results obtained from data recorded with more than 100 electrodes has been previously presented, nor has the importance of dense spatial sampling for EEG source localization accuracy in epilepsy been systematically addressed.

It has been argued (Rosenow and Lüders, 2001) that large array MEG systems should be able to obtain data faster and in a more standardized way than modern EEG systems. However, recently EEG systems allowing for quick application of, and recording from, up to 125 electrodes have become available. Despite this, most epilepsy centers still base their epileptic source localizations on data recorded with standard setups of around 30 electrodes, which according to the theoretical studies should be considered as a severe subsampling. For this reason, studies comparing the results with different electrode setups are imperative. The purpose of the current investigation was to use a recently developed method for distributed source modeling (EPIFOCUS, Grave de Peralta et al., 2001, Lantz et al., 2001a) to compare the accuracy of EEG source localization results with different electrode densities, both for interictal epileptiform activity and for simulated data.

Section snippets

Simulations

For the simulations 9 different electrode configurations were chosen. The 181 electrodes of the basic configuration were uniformly distributed over a spherical surface. From this basic 181-electrode configuration, 8 subsamples were constructed, comprising 166, 131, 100, 89, 68, 49, 31 and 25 electrodes, respectively. In constructing the subsamples it was attempted to, as far as possible, keep the uniformity of the electrode distribution. For each electrode configuration, the lead field matrix

Simulations

The results are presented in Fig. 2. With EPIFOCUS zero localization error (i.e. the source of the simulated potential is localized to exactly the same grid point it originated from) is obtained for virtually all solution points already with 68 electrodes. With the weighted minimum norm algorithm, the number of solution points with zero localization error is much lower for all electrode configurations, and the maximum number is not reached until with 166 electrodes. In order to obtain results

Discussion

Theoretical studies have indicated that around 100 electrodes would be necessary to sample the full surface of the head. Our study fully confirms the insufficiency of the number of electrodes normally used in clinical practice (around 30), and demonstrates the possibility of gain in localization accuracy by increasing the spatial sampling, at least with the current reconstruction models and electrode setups. Indeed, in 9 of our 14 patients the distances from the source localization maximum to

Acknowledgements

This study was supported by the Swiss National Research Foundation (grant No. 31-65232.01) and the Foundation Carlos and Elsie de Reuter.

References (30)

  • A. Gevins

    Distributed neuroelectric patterns of human neocortex during simple cognitive tasks

    Prog Brain Res

    (1990)
  • R. Grave de Peralta et al.

    Noninvasive localization of electromagnetic epileptic activity. 1. Method descriptions and simulations

    Brain Topogr

    (2001)
  • D.W. Gross et al.

    EEG telemetry with closely spaced electrodes in frontal lobe epilepsy

    J Clin Neurophysiol

    (2000)
  • Hämäläinen MS, Ilmoniemi RJ. Interpreting measured magnetic fields of the brain: estimation of current distributions...
  • G. Herrendorf et al.

    Dipole-source analysis in a realistic head model in patients with focal epilepsy

    Epilepsia

    (2000)
  • Cited by (338)

    • Smart instead of high-density EEG

      2023, Clinical Neurophysiology
    View all citing articles on Scopus
    View full text