Abstract
Triaxial accelerometers have been employed to monitor human movements in a variety of circumstances. The study considered the use of data from a single waist-mounted triaxial accelerometer to distinguish between activity states and rest. A method using acceleration magnitude was applied to data collected from 26 normal subjects performing sit-to-stand and stand-to-sittransitions and walking. The effects of three parameters were investigated: the length n of a smoothing median filter, the width w of the averaging window used to process the signal and the value of the acceleration magnitude threshold th. These were found to be inter-related, and sets of parameters that resulted in accurate discrimination were determined by the relationship between th and the product of w and n, and by the relationship between n and w. The subjects were randomly divided into control (N=13) and test (N=13) groups. Optimum parameter sets were determined using the control group. Eleven sets of parameters yielded the same optimum results of a sensitivity of 1.0 and a specificity of 0.96 in the control group. Upon application to the test group, using these parameters, the system successfully distinguished between activity and rest, giving sensitivities greater than 0.98 and specificities between 0.88 and 0.94.
Similar content being viewed by others
References
Bouten, C. V. C., Koekkoek, K. T. M., Verduin, M., Kodde, R., andJanssen, J. D. (1997): ‘A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity’,IEEE Trans. Biomed. Eng.,44, pp. 136–147
Chen, K. Y., andSun, M. (1997): ‘Improving energy expenditure estimation by using a triaxial accelerometer’,J. Appl. Physiol.,83, pp. 2112–2122
Evans, A. L. Duncan, G., andGilchrist, W. (1991): ‘Recording accelerations in body movements’,Med. Biol. Eng. Comput.,29, pp. 102–104
Fahrenberg, J., Foerster, F., Smeja, M. andMüller, W. (1997): ‘Assessment of posture and motion by multichannel piezoresistive accelerometer recordings’,Psychophysiology,34, pp. 607–612
Foerster, F. andFahrenberg, J. (2000): ‘Motion pattern and posture: correctly assessed by calibrated accelerometers’,Behav. Res. Methods, Instrum. Comput.,32, pp. 450–457
Hansson, G.-Å., Asterland, P., Holmer N.-G., andSkerfving,S. (2001): ‘Validity and reliability of triaxial accelerometers for inclinometry in posture analysis’,Med. Biol. Eng. Comput.,39, pp. 405–413
Kerr, K. M., White, J. A., Barr, D. A., andMollan, R. A. B. (1997): ‘Analysis of the sit-stand-sit movement cycle in normal subjects’,Clin. Biomech.,12, pp. 236–245
Mathie, M., Basilakis, J., andCeller, B. G. (2001): ‘A system for monitoring posture and physical activity using accelerometers’. 23rd Annual Int. Conf. of the IEEE Engineering in Medicine and Biology Society, Istanbul, Turkey.
Munro, B. J., Steele, J. R., Bashford, G. M., Ryan, M., andBritten, N. (1998): ‘A kinematic and kinetic analysis of the sitto-stand transfer using an ejector chair: implications for elderly rheumatoid arthritic patients’,J. Biomech.,31, pp. 263–271
Murakami, D., andMakikawa, M. (1997): ‘Ambulatory behavior man, physical activity and biosignal monitoring system’,Methods Inform. Med.,36, pp. 360–363
Sekine, M., Tamura, T., Togawa, T., andFukui, Y. (2000): ‘Classification of waist-acceleration signals in a continuous walking record’,Med. Eng. Phys.,22, pp. 285–291
Uiterwaal, M., Glerum, E. B. C., Busser, H. J., andvan Lummel, R. C. (1998): ‘Ambulatory monitoring of physical activity in working situations, a validation study’,J. Med Eng. Technol.,22, pp. 168–172
Veltink, P. H., Bussmann, H. B. J., de Vries, W., Martens, W.L.J., andvan Lummel, R. C. (1996): ‘Detection of static and dynamic activities using uniaxial accelerometers’,IEEE Trans. Rehabil. Eng.,4, pp. 375–385
Welford, A. T. (1980): ‘Reaction times’ (Academic Press, London, New York).
Westerterp, K. R. (1999):Int. J. Obesity,23, pp. S45-S49
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Mathie, M.J., Coster, A.C.F., Lovell, N.H. et al. Detection of daily physical activities using a triaxial accelerometer. Med. Biol. Eng. Comput. 41, 296–301 (2003). https://doi.org/10.1007/BF02348434
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02348434