Detection of daily physical activities using a triaxial accelerometer

  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

Triaxial accelerometers have been employed to monitor human movements in a variety of circumstances. The study considered the use of data from a single waist-mounted triaxial accelerometer to distinguish between activity states and rest. A method using acceleration magnitude was applied to data collected from 26 normal subjects performing sit-to-stand and stand-to-sittransitions and walking. The effects of three parameters were investigated: the length n of a smoothing median filter, the width w of the averaging window used to process the signal and the value of the acceleration magnitude threshold th. These were found to be inter-related, and sets of parameters that resulted in accurate discrimination were determined by the relationship between th and the product of w and n, and by the relationship between n and w. The subjects were randomly divided into control (N=13) and test (N=13) groups. Optimum parameter sets were determined using the control group. Eleven sets of parameters yielded the same optimum results of a sensitivity of 1.0 and a specificity of 0.96 in the control group. Upon application to the test group, using these parameters, the system successfully distinguished between activity and rest, giving sensitivities greater than 0.98 and specificities between 0.88 and 0.94.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  • Bouten, C. V. C., Koekkoek, K. T. M., Verduin, M., Kodde, R., andJanssen, J. D. (1997): ‘A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity’,IEEE Trans. Biomed. Eng.,44, pp. 136–147

    Article  Google Scholar 

  • Chen, K. Y., andSun, M. (1997): ‘Improving energy expenditure estimation by using a triaxial accelerometer’,J. Appl. Physiol.,83, pp. 2112–2122

    Google Scholar 

  • Evans, A. L. Duncan, G., andGilchrist, W. (1991): ‘Recording accelerations in body movements’,Med. Biol. Eng. Comput.,29, pp. 102–104

    Google Scholar 

  • Fahrenberg, J., Foerster, F., Smeja, M. andMüller, W. (1997): ‘Assessment of posture and motion by multichannel piezoresistive accelerometer recordings’,Psychophysiology,34, pp. 607–612

    Google Scholar 

  • Foerster, F. andFahrenberg, J. (2000): ‘Motion pattern and posture: correctly assessed by calibrated accelerometers’,Behav. Res. Methods, Instrum. Comput.,32, pp. 450–457

    Google Scholar 

  • Hansson, G.-Å., Asterland, P., Holmer N.-G., andSkerfving,S. (2001): ‘Validity and reliability of triaxial accelerometers for inclinometry in posture analysis’,Med. Biol. Eng. Comput.,39, pp. 405–413

    Article  Google Scholar 

  • Kerr, K. M., White, J. A., Barr, D. A., andMollan, R. A. B. (1997): ‘Analysis of the sit-stand-sit movement cycle in normal subjects’,Clin. Biomech.,12, pp. 236–245

    Article  Google Scholar 

  • Mathie, M., Basilakis, J., andCeller, B. G. (2001): ‘A system for monitoring posture and physical activity using accelerometers’. 23rd Annual Int. Conf. of the IEEE Engineering in Medicine and Biology Society, Istanbul, Turkey.

  • Munro, B. J., Steele, J. R., Bashford, G. M., Ryan, M., andBritten, N. (1998): ‘A kinematic and kinetic analysis of the sitto-stand transfer using an ejector chair: implications for elderly rheumatoid arthritic patients’,J. Biomech.,31, pp. 263–271

    Google Scholar 

  • Murakami, D., andMakikawa, M. (1997): ‘Ambulatory behavior man, physical activity and biosignal monitoring system’,Methods Inform. Med.,36, pp. 360–363

    Google Scholar 

  • Sekine, M., Tamura, T., Togawa, T., andFukui, Y. (2000): ‘Classification of waist-acceleration signals in a continuous walking record’,Med. Eng. Phys.,22, pp. 285–291

    Article  Google Scholar 

  • Uiterwaal, M., Glerum, E. B. C., Busser, H. J., andvan Lummel, R. C. (1998): ‘Ambulatory monitoring of physical activity in working situations, a validation study’,J. Med Eng. Technol.,22, pp. 168–172

    Google Scholar 

  • Veltink, P. H., Bussmann, H. B. J., de Vries, W., Martens, W.L.J., andvan Lummel, R. C. (1996): ‘Detection of static and dynamic activities using uniaxial accelerometers’,IEEE Trans. Rehabil. Eng.,4, pp. 375–385

    Google Scholar 

  • Welford, A. T. (1980): ‘Reaction times’ (Academic Press, London, New York).

    Google Scholar 

  • Westerterp, K. R. (1999):Int. J. Obesity,23, pp. S45-S49

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to N. H. Lovell.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Mathie, M.J., Coster, A.C.F., Lovell, N.H. et al. Detection of daily physical activities using a triaxial accelerometer. Med. Biol. Eng. Comput. 41, 296–301 (2003). https://doi.org/10.1007/BF02348434

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02348434

Keywords