Abstract
Rubella-specific IgG in acute-phase sera produces a characteristically altered zone termed “soft hemolysis” in the radial hemolysis test. Here, the soft hemolysis was shown to be a product of the purified IgG1 subclass isolated from acute-phase sera. In contrast, ordinary hemolysis was produced by IgG1 isolated from sera of previous rubella immunity, indicating that the subclass composition of IgG was not involved in the mechanism of soft hemolysis. A novel type of solid-phase immunoassay was developed for the avidity of virus-specific IgG. Acute-phase IgG (with soft hemolysis) was dissociated from rubella antigen in an enzyme immunoassay (EIA) test by hydrogen-bond disrupting agents under conditions where IgG of previous immunity (showing ordinary hemolysis) remained mostly bound. These data suggest that the mechanism of soft hemolysis is the avidity of rubella-specific IgG. The new quantitative avidity EIA was tested with sera taken from 169 subjects. Recent infection could be shown from sera taken weeks or months after primary rubella.
Similar content being viewed by others
References
Gregg NM: Congenital cataract following German measles in the mother. Trans Ophthalmol Soc Austr 3:35–46, 1941
Miller E, Cradock-Watson JE, Pollock TM: Consequences of confirmed maternal rubella of successive stages of pregnancy. Lancet 2:781–784, 1982
Centers for Disease Control: Rubella and congenital rubella syndrome—United States, 1983–1984. Morbid Mortal Week Rep 33:528–530, 1984
Terry GM, Ho-Terry L, Warren RC, Rodeck CH, Cohen A, Rees KR: First trimester prenatal diagnosis of congenital rubella: A laboratory investigation. Br Med J 292:930–933, 1986
Halonen PE, Ryan JM, Stewart JA: Rubella hemagglutinin prepared with alkaline extraction of virus grown in suspension culture of BHK-21 cells. Proc Soc Exp Biol Med 125:162–167, 1967
Stewart GL, Parkman PD, Hopps HE, Douglas RD, Hamilton JP, Meyer HM: Rubella virus hemagglutination-inhibition test. N Engl J Med 276:554–557, 1967
Kalimo KOK, Meurman OH, Halonen PE, Ziola BR, Viljanen MK, Granfors K, Toivanen P: Solid-phase radio-immunoassay of rubella virus immunoglobulin G and immunoglobulin M antibodies. J Clin Microbiol 4:117–123, 1976
Voller A, Bidwell DE: Enzyme-immunoassays for rubella antibodies in measles, cytomegalovirus infections and after rubella vaccination. Br J Exp Pathol 57:243–247, 1976
Lennette EH, Schmidt NJ, Magoffin RL: The hemagglutination inhibition test for rubella: A comparison of its sensitivity to that of neutralization, complement fixation and fluorescent antibody tests for diagnosis of infection and determination of immunity status. J Immunol 99:785–793, 1967
Enders G, Knotek F, Pacher U: Comparison of various serological methods and diagnostic kits for the detection of acute, recent and previous rubella infection, vaccination, and congenital infections. J Med Virol 16:219–232, 1985
Strannegåard O, Grillner L, Lindberg IM: Hemolysis-in-gel test for the demonstration of antibodies to rubella virus. J Clin Microbiol 1:491–494, 1975
Skaug K, Orstavik I, Ulstrup JC: Application of the passive haemolysis test for the determination of rubella virus antibodies. Acta Pathol Microbiol Immunol Scand B 83:367–372, 1975
Väänänen P, Vaheri A: Hemolysis-in-gel test in immunity surveys and diagnosis of rubella. J Med Virol 3:245–252, 1979
Rossier E, Phipps PH, Weber JM, Meurman O: Persistence of humoral and cell-mediated immunity to rubella virus in cloistered nuns and in schoolteachers. J Infect Dis 144:137–141, 1981
Horstmann DM, Schluederberg A, Emmons JE, Evans BK, Randolph MF, Andiman WA: Persistence of vaccine-induced immune responses to rubella: Comparison with natural infection. Rev Infect Dis 7:80–85, 1985
Vesikari T, Vaheri A: Rubella: A method for rapid diagnosis of a recent infection by demonstration of the IgM antibodies. Br Med J 1:221–223, 1968
Stallman ND, Allan BC, Sutherland CJ: Prolonged rubella IgM antibody response. Med J Aust 2:629–631, 1974
Morgan-Capner P, Hambling MH, Coleman TJ, Watkins RP, Stern H, Hodgson J, Dulake C, Boswell PA, Booth J, Best JM, Banatvala JE: Detection of rubella-specific IgM in subclinical rubella reinfection in pregnancy. Lancet 2:244–246, 1985
Hedman K, Räihä K, Meurman O, Vaheri A: Altered hemolysis in single radial hemolysis from a single serum sample as an indicator of recent primary rubella virus infection. J Med Virol 13:323–330, 1984
Hedman K, Salonen EM, Keski-Oja J, Räihä K: Single-serum radial hemolysis to detect recent rubella virus infection. J Infect Dis 154:1018–1023, 1986
Seppälä IJT, Routonen N, Sarnesto A, Mattila PA, Mäkelä O: The percentages of six immunoglobulin isotypes in human antibodies to tetanus toxoid: Standardization of isotype-specific second antibodies in solid-phase assay. Eur J Immunol 14:868–875, 1984
Sarnesto A, Ranta S, Väänänen P, Mäkelä O: Proportions of Ig classes and subclasses in rubella antibodies. Scand J Immunol 21:275–282, 1985
Väänänen P, Vaheri A: Large scale purification of rubella virus and preparation of an experimental split rubella virus vaccine. App Microbiol 22:225–229, 1971
Salonen EM, Vaheri A: Immobilization of viral and mycoplasma antigens and of immunoglobulin on polystyrene surface for immunoassays. J Immunol Methods 30:209–218, 1979
Linde GA: Subclass distribution of rubella virus-specific immunoglobulin G. J Clin Microbiol 21:117–121, 1985
Oker-Blom C, Kalkkinen N, Kääriäinen L, Pettersson R: Rubella virus contains one capsid protein and three envelope glycoproteins, E1, E2a, and E2b. J Virol 46:964–973, 1983
Inouye S, Hasegawa A, Matsuno S, Katow S: Changes in antibody avidity after virus infections: Detection by an immunosorbent assay in which a mild protein-denaturing agent is employed. J Clin Microbiol 20:525–529, 1984
Lehtonen OP, Meurman OH: An ELISA for the estimation of high-avidity and total specific IgG and IgM antibodies to rubella virus. J Virol Methods 5:1–10, 1982
Eisen HN, Siskind GW: Variations in affinities of antibodies during the immune response. Biochemistry 3:996–1008, 1964
Werblin TP, Kim YT, Quagliata F, Siskind GW: Studies on the control of antibody synthesis. III. Changes in heterogeneity of antibody affinity during the course of the immune response. Immunology 24:477–492, 1973
Brown SE, Zuckerman AJ, Howard CR, Steward MW: Affinity of antibody response in man to hepatitis B vaccine determined with synthetic peptides. Lancet 2:184–187, 1984
Peterfy F, Kuusela P, Mäkelä O: Affinity requirements for antibody assays mapped by monoclonal antibodies. J Immunol 130:1809–1813, 1983
Steward MW, Lew AM: The importance of antibody affinity in the performance of immunoassays for antibody. J Immunol Methods 78:173–190, 1985
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Hedman, K., Seppälä, I. Recent rubella virus infection indicated by a low avidity of specific IgG. J Clin Immunol 8, 214–221 (1988). https://doi.org/10.1007/BF00917569
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00917569