TY - JOUR T1 - Low-Cost Differential Pressure Spirometry for Emergency Ventilator Tidal Volume Sensing JF - medRxiv DO - 10.1101/2020.09.25.20198069 SP - 2020.09.25.20198069 AU - Jordan L. Edmunds AU - Mauricio J. Bustamante AU - David K. Piech AU - Jonathan S. Schor AU - Samuel J. Raymond AU - David B. Camarillo AU - Michel M. Maharbiz Y1 - 2020/01/01 UR - http://medrxiv.org/content/early/2020/09/27/2020.09.25.20198069.abstract N2 - COVID-19 has become a significant burden on the healthcare systems in the United States and around the world, with many patients requiring invasive mechanical ventilation (IMV) to survive. Close monitoring of patients is critical, with total volume per breath (tidal volume) being one of the most important data points. However, ventilators are complex and expensive devices, typically in the range of tens of thousands of US dollars, and are challenging to manufacture, typically requiring months. Solutions which could augment the ventilator supply rapidly and at low cost in the United States and elsewhere would be valuable. In this paper, we present a standalone tidal volume measurement system consisting of a D-Lite spirometer, pressure sensor, microcontroller, and tubing with a cost of parts less than $50 USD. We also provide a model to predict the error in tidal volume measurements based on the pressure sensor used and the flow during ventilation. We validate this system and show that the tidal volume accuracy for flows above 10 L/min was within 10%. We envision this system being used to increase the ventilator supply in resource-constrained settings.Competing Interest StatementThe authors have declared no competing interest.Funding StatementAn ongoing grant from the Chan Zuckerberg Biohub funded the graduate students involved in the work. Money used to purchase most of the supplies used was from the UCSF COVID-19 Response Fund. One author is receiving ongoing support from the Hertz Foundation. No external services were given by third parties or were involved in the study design except as stated by the Acknowledgements.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:As this paper describes the design and analysis of a medical devices that was not tested on humans no IRB approval was requested.All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesAll raw data is available on our group's google drive. Code used for online data processing can be found on github. Both links are available below. https://drive.google.com/drive/u/0/folders/1wQxoaZd3DSQLKDs2eLh8qEjYdGccdzsO https://github.com/edmundsj/TidalVolumeArduino ER -