PT - JOURNAL ARTICLE AU - Klaus, Mike D. AU - Laqua, Fabian AU - Baeßler, Bettina AU - Ankenbrand, Markus J. TI - Stability of Dynamic Radiomics Features in Cardiac MRI AID - 10.1101/2025.04.18.25326051 DP - 2025 Jan 01 TA - medRxiv PG - 2025.04.18.25326051 4099 - http://medrxiv.org/content/early/2025/04/25/2025.04.18.25326051.short 4100 - http://medrxiv.org/content/early/2025/04/25/2025.04.18.25326051.full AB - Background Radiomic studies on cardiac MR mainly focus on images from distinct time points rather than considering the system’s dynamic nature. Recent studies have shown that radiomic features exhibit considerable variation across the cardiac cycle and that dynamic features can improve classification accuracy in downstream tasks. However, it is unclear whether the dynamic temporal evolution of radiomic features is sufficiently stable in the presence of noise.Purpose In this work, we evaluate the stability of radiomic feature curves of cine CMR images under noise.Methods We extracted over 800 radiomic features from all time points of cine CMR images of 35 subjects from three cohorts with various levels of artificially added noise. The stability of feature curves is evaluated based on pairwise normalized mean squared errors, and features are ranked by their stability.Results Features exhibit a varying degree of stability, but stability is consistent across subjects. Besides generally stable and unstable features, some features are stable within the same noise level but unstable otherwise.Conclusion Some radiomic feature curves remain stable under noise while showing variability over the cardiac cycle. These features are promising candidates for improving models using dynamic rather than static feature values.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThis study did not receive any fundingAuthor DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:The study uses three data sets. 1. MRXCAT - this is purely simulated data 2. ACDC - this is publically available data (https://www.creatis.insa-lyon.fr/Challenge/acdc/index.html) 3. BAE - this is data from a previously published study (doi:10.1016/j.ejrad.2015.08.002) with available ethics approval and written informed consent given by all volunteersI confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.YesAll code is available via GitHub (https://github.com/BioMeDS/cmr-dynamic-radiomics-stability) and Zenodo (https://doi.org/10.5281/zenodo.15239556). Large files, including simulation data, result tables, and figures are available as dvcstore via Zenodo (https://doi.org/10.5281/zenodo.15239918). ACDC data is available through their website. BAE data is not publicly available. https://github.com/BioMeDS/cmr-dynamic-radiomics-stability https://doi.org/10.5281/zenodo.15239556 https://doi.org/10.5281/zenodo.15239918 https://www.creatis.insa-lyon.fr/Challenge/acdc/index.html