RT Journal Article SR Electronic T1 Quantitative particle analysis of particulate matter release during orthodontic procedures: A pilot study JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2020.09.09.20191270 DO 10.1101/2020.09.09.20191270 A1 Ahmed Riaz Din A1 Annika Hindocha A1 Tulsi Patel A1 Sanjana Sudarshan A1 Neil Cagney A1 Amine Koched A1 Jens-Dominik Mueller A1 Noha Seoudi A1 Claire Morgan A1 Shakeel Shahdad A1 Padhraig S. Fleming YR 2020 UL http://medrxiv.org/content/early/2020/09/11/2020.09.09.20191270.abstract AB Introduction Transmission of SARS-Cov-2 through aerosol has been implicated particularly in the presence of highly concentrated aerosols in enclosed environments. It is accepted that aerosols are produced during a range of dental procedures, posing potential risks to both dental practitioners and patients. There has been little agreement concerning aerosol transmission associated with orthodontics and associated mitigation.Methods Orthodontic procedures were simulated in a closed side-surgery using a dental manikin on an acrylic model using composite-based adhesive. Adhesive removal representing debonding was undertaken using a 1:1 contra-angle handpiece (W&H Synea™ Vision WK-56 LT, Bürmoos, Austria) and fast hand-piece with variation in air and water flow. The removal of acid etch was also simulated with use of combined 3-in-1 air water syringe to remove etch. An Optical Particle Sizer (OPS 3330, TSI Inc. Minnesota, USA) and a portable Scanning Mobility Particle Sizer (NanoScan SMPS Nanoparticle Sizer 3910, TSI Inc Minnesota, USA) were both to assess particulate matter ranging from ‘very small’ (0.08 – 0.26 μm) to ‘large’ (2.7 – 10 μm) particles.Results Standard debonding procedure (involving air but no water) was associated with clear increase in the ‘very small’ and ‘small’ (0.26 – 0.9 μm) particles but only for a short period. Debonding procedures without air appeared to produce similar levels of aerosol to standard debonding. Debonding in association with water tended to produce large increase in aerosol levels, producing particles of all sizes throughout the experiment. The use of water and a fast hand-piece led to the most significant increase in particles. Combined use of the 3-in-1 air water syringe did not result in any detectable increase in the aerosol levels.Conclusions Particulate matter was released during orthodontic debonding, although the concentration and volume was markedly less than that associated with the use of a fast hand-piece. No increase in particulates was associated with prolonged use of a 3-in-1 air-water syringe. Particulate levels reduced to baseline levels over a short period (approx. 5 minutes). Further research within alternative, open environments and without air exchange systems is required.Competing Interest StatementThe authors have declared no competing interest.Funding StatementNo external funding was receivedAuthor DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:None required. Laboratory-based studyAll necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesAll data is available for review