TY - JOUR T1 - The Role of Air Conditioning in the Diffusion of Sars-CoV-2 in Indoor Environments: a First Computational Fluid Dynamic Model, based on Investigations performed at the Vatican State Children’s Hospital JF - medRxiv DO - 10.1101/2020.08.25.20181420 SP - 2020.08.25.20181420 AU - Luca Borro AU - Lorenzo Mazzei AU - Massimiliano Raponi AU - Prisco Piscitelli AU - Alessandro Miani AU - Aurelio Secinaro Y1 - 2020/01/01 UR - http://medrxiv.org/content/early/2020/08/31/2020.08.25.20181420.abstract N2 - Background About 15 million people worldwide were affected by the Sars-Cov-2 infection, which already caused 600,000 deaths. This virus is mainly transmitted through exhalations from the airways of infected persons, so that Heating, Ventilation and Air Conditioning (HVAC) systems might play a role in increasing or reducing the spreading of the infection in indoor environments.Methods We modelled the role of HVAC systems in the diffusion of the contagion through Computational Fluid Dynamics (CFD) simulations of cough at the “Bambino Gesù” Vatican State Children’s Hospital.Both waiting and hospital rooms were modeled as indoor scenarios. A specific Infection-Index (η) parameter was used to estimate the amount of contaminated air inhaled by each person present in the simulated indoor scenarios. The potential role of exhaust air ventilation systems placed above the coughing patient’s mouth was also assessed.Results Our CFD-based simulations of the waiting room show that HVAC air-flow remarkably enhances infected droplets diffusion in the whole indoor environment within 25 seconds from the cough event, despite the observed dilution of saliva particles containing the virus. At the same time also their number is reduced due to removal through the HVAC system or deposition on the surfaces. The proper use of Local Exhaust Ventilation systems (LEV) simulated in the hospital room was associated to a complete reduction of infected droplets spreading from the patient’s mouth in the first 0.5 seconds following the cough event. In the hospital room, the use of LEV system completely reduced the η index computed for the patient hospitalized at the bed next to the spreader, with a decreased possibility of contagion.Conclusions CFD-based simulations for indoor environment can be useful to optimize air conditioning flow and to predict the contagion risk both in hospitals/ambulatories and in other public/private settings.Competing Interest StatementThe authors have declared no competing interest.Funding StatementNo external funding receivedAuthor DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:Bambino Gesu Childrens Hospital - Scientific DirectorateAll necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).Yes I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesThe authors confirm that the data supporting the findings of this study are available within the article and its supplementary materials. ER -