TY - JOUR T1 - Fully Automated Delineation of the Optic Radiation for Surgical Planning using Clinically Accessible Sequences JF - medRxiv DO - 10.1101/2020.07.16.20155598 SP - 2020.07.16.20155598 AU - Lee B Reid AU - Eloy Martínez-Heras AU - Jose V Manjón AU - Rosalind L. Jeffree AU - Hamish Alexander AU - Julie Trinder AU - Elisabeth Solana AU - Sara Llufriu AU - Stephen Rose AU - Marita Prior AU - Jurgen Fripp Y1 - 2020/01/01 UR - http://medrxiv.org/content/early/2020/07/18/2020.07.16.20155598.abstract N2 - Quadrantanopia caused by inadvertent severing of Meyer’s Loop of the optic radiation is a well-recognised complication of temporal lobectomy for conditions such as epilepsy. Dissection studies indicate that the anterior extent of Meyer’s Loop varies considerably between individuals. Quantifying this for individual patients is thus an important step to improve the safety profile of temporal lobectomies. Previous attempts to delineate Meyer’s Loop using diffusion MRI tractography have had difficulty estimating its full anterior extent, required manual ROI placement, and/or relied on advanced diffusion sequences that cannot be acquired routinely in most clinics. Here we present CONSULT – a pipeline that can delineate the optic radiation from raw DICOM data in a completely automated way via a combination of robust preprocessing, segmentation, and alignment stages, plus simple improvements that bolster the efficiency and reliability of standard tractography. We tested CONSULT on 694 scans of predominantly healthy participants (538 unique brains), including both advanced acquisitions and simpler acquisitions that could be acquired in clinically acceptable timeframes. Delineations completed without error in 99.4% of the scans. The distance between Meyer’s Loop and the temporal pole closely matched both averages and ranges reported in dissection studies for all tested sequences. Median scan-rescan error of this distance was 1mm. When tested on two participants with considerable pathology, delineations were successful and realistic. Through this, we demonstrate not only how to identify Meyer’s Loop with clinically accessible sequences, but also that this can be achieved without fundamental changes to tractography algorithms or complex post-processing methods.HighlightsWe propose a fully automated means of delineating the optic radiation using diffusion MRI from DICOM dataAnatomical measurements from tractography of over 500 brains align well with previous dissection studiesThe proposed pipeline works well with clinically accessible and advanced acquisitionsMedian scan-rescan error was 1mmPlausible tractography was generated when pathology was presentCompeting Interest StatementThe authors have declared no competing interest.Funding StatementThis research was partially supported by an Advance Queensland Research Fellowship (R-09964-01), as well as the Spanish DPI2017-87743-R grant from the Ministerio de Economia, Industria y Competitividad of Spain. The authors gratefully acknowledge the support of NVIDIA Corporation with their donation of the TITAN X GPU used in this research.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:Ethics was obtained by the appropriate bodies for: 1. Metro North, Queensland, Australia 2. Hospital Clinic, Barcelona, Spain 3. CSIRO, AustraliaAll necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesPopulation averages can be requested from the authors. Due to the risk of de-identification, data from individual patients cannot be requested ER -