RT Journal Article SR Electronic T1 Inexpensive multi-patient respiratory monitoring system for helmet ventilation during COVID-19 pandemic JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2020.06.29.20141283 DO 10.1101/2020.06.29.20141283 A1 The Princeton Open Ventilation Monitor Collaboration A1 Philippe Bourrianne A1 Stanley Chidzik A1 Daniel Cohen A1 Peter Elmer A1 Thomas Hallowell A1 Todd J. Kilbaugh A1 David Lange A1 Andrew M. Leifer A1 Daniel R. Marlow A1 Peter D. Meyers A1 Edna Normand A1 Janine Nunes A1 Myungchul Oh A1 Lyman Page A1 Talmo Periera A1 Jim Pivarski A1 Henry Schreiner A1 Howard A. Stone A1 David W. Tank A1 Stephan Thiberge A1 Christopher Tully YR 2020 UL http://medrxiv.org/content/early/2020/06/30/2020.06.29.20141283.abstract AB Helmet non-invasive ventilation (NIV) is a form of continuous positive applied pressure that has emerged as a useful therapy for COVID-19 patients who require respiratory support but may not require invasive ventilation. Helmet NIV has seen an increase in use during the COVID-19 pandemic because it is low-cost, readily available, and provides viral filters between the patient and clinician. Helmet NIV may also provide better patient outcomes by delaying or eliminating the need for invasive ventilation. Its widespread adoption has been limited, however, by the lack of a respiratory monitoring system that is needed to address known safety vulnerabilities and to provide clinicians with a respiratory profile of the patient. To address this safety need, we have developed an inexpensive respiratory monitoring system that is based on readily available commercial components and is suitable for rapid local manufacture. The system is designed for use in conjunction with the COVID-19 Helmet developed by Sea-Long Medical Systems [1], but is modular and can be used with other ventilation systems. The monitoring system comprises one or more flow and pressure sensors and a central remote station that can be used to remotely monitor up to 20 patients simultaneously. The system reports flow, pressure, and clinically relevant metrics including respiratory rate, tidal volume equivalent, peak inspiratory pressure (PIP), positive end-expiratory pressure (PEEP) and the ratio of inspiratory time to expiratory time (I:E). The device will sound alarms based on clinician-set thresholds. In bench tests using a commercial ventilator and artificial lung system, our device performs comparably to a commercial single-patient respiratory monitor. Results are presented from human-subject tests on a healthy volunteer undergoing helmet non-invasive ventilation. Detailed design and manufacturing documents are provided.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThis work was supported by National Science Foundation grants OAC-1836650, 574PHY-2031509 and IOS-1845137.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:Human subject tests were conducted in accordance with IRB protocol #12857 approved by Princeton University's Institutional Review Board.All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesRelevant human subject data is included as supplementary material. All design files are included as supplementary material. Links to software repositories are included in the manuscript.