RT Journal Article SR Electronic T1 A handheld point-of-care system for rapid detection of SARS-CoV-2 in under 20 minutes JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2020.06.29.20142349 DO 10.1101/2020.06.29.20142349 A1 Jesus Rodriguez-Manzano A1 Kenny Malpartida-Cardenas A1 Nicolas Moser A1 Ivana Pennisi A1 Matthew Cavuto A1 Luca Miglietta A1 Ahmad Moniri A1 Rebecca Penn A1 Giovanni Satta A1 Paul Randell A1 Frances Davies A1 Frances Bolt A1 Wendy Barclay A1 Alison Holmes A1 Pantelis Georgiou YR 2020 UL http://medrxiv.org/content/early/2020/06/30/2020.06.29.20142349.abstract AB The COVID-19 pandemic is a global health emergency characterized by the high rate of transmission and ongoing increase of cases globally. Rapid point-of-care (PoC) diagnostics to detect the causative virus, SARS-CoV-2, are urgently needed to identify and isolate patients, contain its spread and guide clinical management. In this work, we report the development of a rapid PoC diagnostic test (< 20 min) based on reverse transcriptase loop-mediated isothermal amplification (RT-LAMP) and semiconductor technology for the detection of SARS-CoV-2 from extracted RNA samples. The developed LAMP assay was tested on a real-time benchtop instrument (RT-qLAMP) showing a lower limit of detection of 10 RNA copies per reaction. It was validated against 183 clinical samples including 127 positive samples (screened by the CDC RT-qPCR assay). Results showed 90.55% sensitivity and 100% specificity when compared to RT-qPCR and average positive detection times of 15.45 ± 4.43 min. For validating the incorporation of the RT-LAMP assay onto our PoC platform (RT-eLAMP), a subset of samples was tested (n=40), showing average detection times of 12.89 ± 2.59 min for positive samples (n=34), demonstrating a comparable performance to a benchtop commercial instrument. Paired with a smartphone for results visualization and geo-localization, this portable diagnostic platform with secure cloud connectivity will enable real-time case identification and epidemiological surveillance.One Sentence Summary We demonstrate isothermal detection of SARS-CoV-2 in under 20 minutes from extracted RNA samples with a handheld Lab-on-Chip platform.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThis work was supported by the Imperial College COVID19 Research Fund (G38041 and PSH819 Awards) and the NIHR Imperial Biomedical Research Centre (P80763). We would also like to thank the Imperial College Healthcare NHS Trust microbiology lab for providing the samples. Professor A.H is a National Institute for Health Research (NIHR) Senior Investigator. We would also like to acknowledge EPSRC HiPEDS CDT (EP/L016796/1 to K.M.C) and EPSRC DTP (EP/N509486/1 to A.M.) for supporting this work.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:We have collected a total of 183 nasopharyngeal, throat and nose swabs. All studies were conducted in accordance with the ethical approval (20/HRA/1561; DOCUMAS 20SM5875).All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesAll data available upon request.