TY - JOUR T1 - The Effect of Ultraviolet C Radiation Against SARS-CoV-2 Inoculated N95 Respirators JF - medRxiv DO - 10.1101/2020.05.31.20118588 SP - 2020.05.31.20118588 AU - David M. Ozog AU - Jonathan Z. Sexton AU - Shanthi Narla AU - Carla D. Pretto-Kernahan AU - Carmen Mirabelli AU - Henry W. Lim AU - Iltefat H. Hamzavi AU - Robert J. Tibbetts AU - Qing-Sheng Mi Y1 - 2020/01/01 UR - http://medrxiv.org/content/early/2020/06/26/2020.05.31.20118588.abstract N2 - Since March 31st, 2020, during the height of the pandemic, we have decontaminated thousands of 3M 1860 respirators with Ultraviolet C (UVC) for our frontline workers. There is no published peer-reviewed data regarding the dose required to effectively disinfect SARS-CoV-2 on N95 filtering facepiece respirators (FFRs). Four different locations (facepiece and strap) on 5 different N95 FFR models (3M 1860, 8210, 8511, 9211; Moldex 1511) were inoculated with a 10 μL drop of SARS-CoV-2 viral stock (8 × 107 TCID50/mL). The outside-facing and wearer-facing surfaces of the respirators were each irradiated with a dose of 1.5 J/cm2 UVC (254 nm).Viable SARS-CoV-2 was quantified by a median tissue culture infectious dose assay (TCID50). UVC delivered using a dose of 1.5 J/cm2, to each side, was an effective method of decontamination for the facepieces of 3M 1860 and Moldex 1511, and for the straps of 3M 8210 and the Moldex 1511. This dose is an appropriate decontamination method to facilitate reuse of respirators for healthcare personnel when applied to certain models/materials. Increasing the dose may improve decontamination for the other models and straps; however, UVC radiation can degrade certain polymers in a dose dependent manner, and the effects may vary greatly between different models. Therefore, fit-testing of UVC decontaminated respirators must be performed each time a new model and/or dose is introduced into the healthcare system.Competing Interest StatementSN is a sub-investigator for Biofrontera. DO is an investigator for Biofrontera. HWL is an investigator for LITE study which is funded by PCORI, and home phototherapy machines are provided by Daavlin, and has participated as a speaker in general educational session for Ra Medical System. IHH is an investigator for LITE study which is funded by PCORI, and home phototherapy machines are provided by Daavlin. JZS, CDPK, CM, RJT and QSM have no conflicts of interest to report at this time.Funding StatementNo external funding was received.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:All study procedures were approved and conducted according to the University of Michigan Institutional Biosafety Committee BSL3 (Biosafety Level 3).All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesAll data generated or analyzed during this study are included in this published article (and its supplementary information files). ER -