RT Journal Article SR Electronic T1 Holistic Structural Visualization of Coronary Arteries with Single-catheter Dual-modality Intravascular Imaging Combining IVUS and OFDI JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2020.06.19.20130302 DO 10.1101/2020.06.19.20130302 A1 Ren, Jian A1 Shishkov, Milen A1 Villiger, Martin A1 Otsuka, Kenichiro A1 Nadkarni, Seemantini A1 Bouma, Brett YR 2020 UL http://medrxiv.org/content/early/2020/06/22/2020.06.19.20130302.abstract AB Objectives To test the imaging performance and practical use of a novel dual-modality intravascular imaging system combining intravascular ultrasound (IVUS) and optical coherence tomography (OCT) into a single catheter.Background IVUS enables assessing coronary plaque burden, a robust metric for patient prognosis, while OCT and OFDI provide high-resolution images of coronary microstructure and detailed assessment of stent implantation. Owing to their complementary strengths, co-registering IVUS and OFDI provides a more comprehensive assessment of coronary lesions during PCI.Methods We developed a 2.6Fr imaging catheter integrating both IVUS and OFDI, interfacing to a dual-modality imaging console through a fast interchange connector. A novel algorithm fuses the IVUS and OFDI signals into a single combined image. We verified the performance of the two modalities and their visualization by imaging of cadaveric coronary arteries and tested practical imaging in the catheterization laboratory in swine in vivo.Results Coronary atherosclerotic lesions of cadaver hearts revealed complementary optical and acoustic image features. Spatial co-registration of the modalities was confirmed by high correlation of measured lumen areas. Fused into a combined visualization, dual-modality imaging offers quantitative characterization of lesions, including plaque-burden and fibrous cap thickness. Imaging in vivo does not add procedural complexity compared to conventional single modality imaging.Conclusion Dual-modality IVUS/OFDI imaging with fused visualization provides improved assessment of coronary atherosclerotic lesions and is compatible with a routine clinical setting. Combining the strength of the two modalities offers unique opportunities both as a powerful research instrument and to improve clinical management of patients undergoing PCI.Visual abstract Highlights▪ A catheter-based imaging system integrating ultrasound and optical frequency domain imaging enables real time intravascular holistic structural visualization (IV-HSV) of coronary arterial lesions with a single pullback during cardiac catheterization procedures.▪ A computational method to automatically fuse images from both modalities generates a single complete map of vessel wall structures - the IV-HSV image, which offers holistic investigation of coronary plaque key features, such as fibrous cap thickness, calcification, and plaque burden.▪ The visualization of plaque morphology along the entire extent of the coronary arterial wall reveals vital information for guiding percutaneous coronary interventions and for advancing our understanding of the pathophysiology of coronary artery diseases.Condensed abstract To facilitate a holistic investigation of coronary arterial lesions for both basic research and clinical interventions, this work presents a catheter-based imaging system integrating IVUS and OFDI, as well as a new rendering method that computationally fuses the intrinsically co-registered images from both modalities into a single cross-sectional map of vessel structures. Imaging human cadaveric coronary arteries shows the benefit of this system by revealing near-lumen microstructures and spatially correlated macrostructures deep inside the vessel wall. The co-registration accuracy and operation in a clinical setting of this system was demonstrated through swine catheterization in vivo.Competing Interest StatementMassachusetts General Hospital has patent licensing arrangements with Terumo Corporation. Drs. Bouma and Villiger have the right to receive royalties as part of the licensing arrangements. All other authors have reported that they have no relationships relevant to the contents of this paper to disclose.Funding StatementThis work was supported by the National Institutes of Health (P41EB015903, K99AG059946, and R01HL119065) and by Terumo Corporation.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:The swine studies in this work were approved by the Massachusetts General Hospital Institutional Animal Care and Use Committee and performed with generally accepted guidelines governing such work.All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesThe data that support the findings of this study are available from the corresponding author upon reasonable requestACSacute coronary syndromeCSAcross sectional areaEEMexternal elastic membraneIV-HSVintravascular holistic structural visualizationIVUSintravascular ultrasoundLADleft anterior descending arteryLCXleft circumflex arteryOCToptical coherence tomographyOFDIoptical frequency domain imagingPCIpercutaneous coronary interventionTCFAthin-capped fibroatheroma