RT Journal Article SR Electronic T1 Deep Learning Improves Pre-Surgical White Matter Visualization in Glioma Patients JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2020.06.18.20133108 DO 10.1101/2020.06.18.20133108 A1 Sandip S Panesar A1 Vishwesh Nath A1 Sudhir K Pathak A1 Walter Schneider A1 Bennett A. Landman A1 Michael Iv A1 Diana Anthony A1 Tatiana Jansen A1 Kumar Abhinav A1 Juan Fernandez-Miranda YR 2020 UL http://medrxiv.org/content/early/2020/06/20/2020.06.18.20133108.abstract AB Background Diffusion tensor imaging (DTI) is a commonly utilized pre-surgical tractography technique. Despite widespread use, DTI suffers from several critical limitations. These include an inability to replicate crossing fibers and a low angular-resolution, affecting quality of results. More advanced, non-tensor methods have been devised to address DTI’s shortcomings, but they remain clinically underutilized due to lack of awareness, logistical and cost factors.Objective Nath et al. (2020) described a method of transforming DTI data into non-tensor high-resolution data, suitable for tractography, using a deep learning technique. This study aims to apply this technique to real-life tumor cases.Methods The deep learning model utilizes a residual convolutional neural network architecture to yield a spherical harmonic representation of the diffusion-weighted MR signal. The model was trained using normal subject data. DTI data from clinical cases were utilized for testing: Subject 1 had a right-sided anaplastic oligodendroglioma. Subject 2 had a right-sided glioblastoma. We conducted deterministic fiber tractography on both the DTI data and the post-processed deep learning algorithm datasets.Results Generally, all tracts generated using the deep learning algorithm dataset were qualitatively and quantitatively (in terms of tract volume) superior than those created with DTI data. This was true for both test cases.Conclusions We successfully utilized a deep learning technique to convert standard DTI data into data capable of high-angular resolution tractography. This method dispenses with specialized hardware or dedicated acquisition protocols. It presents an economical and logistically feasible method for increasing access to high definition tractography imaging clinically.Competing Interest StatementThe authors have declared no competing interest.Funding StatementNo funding received.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:Stanford University.All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesAll data used in this paper can be obtained by contacting the relevant authors.