PT - JOURNAL ARTICLE AU - Brian J. Park AU - Vlasios S. Sotirchos AU - Jason Adleberg AU - S. William Stavropoulos AU - Tessa S. Cook AU - Stephen J. Hunt TI - Feasibility and visualization of deep learning detection and classification of inferior vena cava filters AID - 10.1101/2020.06.06.20124321 DP - 2020 Jan 01 TA - medRxiv PG - 2020.06.06.20124321 4099 - http://medrxiv.org/content/early/2020/06/08/2020.06.06.20124321.short 4100 - http://medrxiv.org/content/early/2020/06/08/2020.06.06.20124321.full AB - Purpose This study assesses the feasibility of deep learning detection and classification of 3 retrievable inferior vena cava filters with similar radiographic appearances and emphasizes the importance of visualization methods to confirm proper detection and classification.Materials and Methods The fast.ai library with ResNet-34 architecture was used to train a deep learning classification model. A total of 442 fluoroscopic images (N=144 patients) from inferior vena cava filter placement or removal were collected. Following image preprocessing, the training set included 382 images (110 Celect, 149 Denali, 123 Günther Tulip), of which 80% were used for training and 20% for validation. Data augmentation was performed for regularization. A random test set of 60 images (20 images of each filter type), not included in the training or validation set, was used for evaluation. Total accuracy and receiver operating characteristic area under the curve were used to evaluate performance. Feature heatmaps were visualized using guided backpropagation and gradient-weighted class activation mapping.Results The overall accuracy was 80.2% with mean receiver operating characteristic area under the curve of 0.96 for the validation set (N=76), and 85.0% with mean receiver operating characteristic area under the curve of 0.94 for the test set (N=60). Two visualization methods were used to assess correct filter detection and classification.Conclusions A deep learning model can be used to automatically detect and accurately classify inferior vena cava filters on radiographic images. Visualization techniques should be utilized to ensure deep learning models function as intended.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThe Titan Xp used for this research was donated by NVIDIA Corporation.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:University of PennsylvaniaAll necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesData may be available upon request. No external datasets were used.CNNconvolutional neural networkEKGelectrocardiogramGrad-CAMgradient-weighted class activation mappingGBPguided backpropagationIVCinferior vena cavaMLmachine learningROC AUCreceiver operating characteristic area under the curve