PT - JOURNAL ARTICLE AU - Mario Plebani AU - Andrea Padoan AU - Davide Negrini AU - Benedetta Carpinteri AU - Laura Sciacovelli TI - Diagnostic performances and thresholds: the key to harmonization in serological SARS-CoV-2 assays? AID - 10.1101/2020.05.22.20106328 DP - 2020 Jan 01 TA - medRxiv PG - 2020.05.22.20106328 4099 - http://medrxiv.org/content/early/2020/05/26/2020.05.22.20106328.short 4100 - http://medrxiv.org/content/early/2020/05/26/2020.05.22.20106328.full AB - Background The evaluation of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) specific antibody (Ab) assay performances is of the utmost importance in establishing and monitoring virus spread in the community. In this study focusing on IgG antibodies, we compare reliability of three chemiluminescent (CLIA) and two enzyme linked immunosorbent (ELISA) assays.Methods Sera from a total of 271 subjects, including 64 reverse transcription-polymerase chain reaction (RT-PCR) confirmed SARS-CoV-2 patients were tested for specific Ab using Maglumi (Snibe), Liaison (Diasorin), iFlash (Yhlo), Euroimmun (Medizinische Labordiagnostika AG) and Wantai (Wantai Biological Pharmacy) assays. Diagnostic sensitivity and specificity, positive and negative likelihood ratios were evaluated using manufacturers’ and optimized thresholds.Results Optimized thresholds (Maglumi 2 kAU/L, Liaison 6.2 kAU/L and iFlash 15.0 kAU/L) allowed us to achieve a negative likelihood ratio and an accuracy of: 0.06 and 93.5% for Maglumi; 0.03 and 93.1% for Liaison; 0.03 and 91% for iFlash. Diagnostic sensitivities and specificities were above 93.8% and 85.9%, respectively for all CLIA assays. Overall agreement was 90.3% (Cohen’s kappa = 0.805 and SE = 0.041) for CLIA, and 98.4% (Cohen’s kappa = 0.962 and SE = 0.126) for ELISA.Conclusions The results obtained indicate that, for CLIA assays, it might be possible to define thresholds that improve the negative likelihood ratio. Thus, a negative test result enables the identification of subjects at risk of being infected, who should then be closely monitored over time with a view to preventing further viral spread. Redefined thresholds, in addition, improved the overall inter-assay agreement, paving the way to a better harmonization of serologic tests.Competing Interest StatementThe authors have declared no competing interest.Funding StatementNo funds are requested or obtained for this studyAuthor DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:In the manuscript body, we stated that: The study protocol (number 23307) was approved by the Ethics Committee of the University-Hospital, Padova.All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesData are available on requests, if the journal policy will allowed that.