RT Journal Article SR Electronic T1 Assisting Scalable Diagnosis Automatically via CT Images in the Combat against COVID-19 JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2020.05.11.20093732 DO 10.1101/2020.05.11.20093732 A1 Liu, Bohan A1 Liu, Pan A1 Dai, Lutao A1 Yang, Yanlin A1 Xie, Peng A1 Tan, Yiqing A1 Du, Jicheng A1 Shan, Wei A1 Zhao, Chenghui A1 Zhong, Qin A1 Lin, Xixiang A1 Guan, Xizhou A1 Xing, Ning A1 Sun, Yuhui A1 Wang, Wenjun A1 Zhang, Zhibing A1 Fu, Xia A1 Fan, Yanqing A1 Li, Meifang A1 Zhang, Na A1 Li, Lin A1 Liu, Yaou A1 Xu, Lin A1 Du, Jingbo A1 Zhao, Zhenhua A1 Hu, Xuelong A1 Fan, Weipeng A1 Wang, Rongpin A1 Wu, Chongchong A1 Nie, Yongkang A1 Cheng, Liuquan A1 Ma, Lin A1 Li, Zongren A1 Jia, Qian A1 Liu, Minchao A1 Guo, Huayuan A1 Huang, Gao A1 Shen, Haipeng A1 An, Weimin A1 Li, Hao A1 Zhou, Jianxin A1 He, Kunlun YR 2020 UL http://medrxiv.org/content/early/2020/05/15/2020.05.11.20093732.abstract AB The pandemic of coronavirus Disease 2019 (COVID-19) caused enormous loss of life globally. 1-3 Case identification is critical. The reference method is using real-time reverse transcription PCR (rRT-PCR) assays, with limitations that may curb its prompt large-scale application. COVID-19 manifests with chest computed tomography (CT) abnormalities, some even before the onset of symptoms. We tested the hypothesis that application of deep learning (DL) to the 3D CT images could help identify COVID-19 infections. Using the data from 920 COVID-19 and 1,073 non-COVID-19 pneumonia patients, we developed a modified DenseNet-264 model, COVIDNet, to classify CT images to either class. When tested on an independent set of 233 COVID-19 and 289 non-COVID-19 patients. COVIDNet achieved an accuracy rate of 94.3% and an area under the curve (AUC) of 0.98. Application of DL to CT images may improve both the efficiency and capacity of case detection and long-term surveillance.Competing Interest StatementThe authors have declared no competing interest.Clinical TrialChiCTR2000030390Clinical Protocols http://www.chictr.org.cn/showproj.aspx?proj=50224 Funding StatementThe code and CT image data, as well as clinical data were available only for research after obtaining the agreement of corresponding authors.Author DeclarationsAll relevant ethical guidelines have been followed; any necessary IRB and/or ethics committee approvals have been obtained and details of the IRB/oversight body are included in the manuscript.YesAll necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesThe code and CT image data, as well as clinical data were available only for research after obtaining the agreement of corresponding authors.