TY - JOUR T1 - Pneumask: Modified Full-Face Snorkel Masks as Reusable Personal Protective Equipment for Hospital Personnel JF - medRxiv DO - 10.1101/2020.04.24.20078907 SP - 2020.04.24.20078907 AU - Laurel Kroo AU - Anesta Kothari AU - Melanie Hannebelle AU - George Herring AU - Thibaut Pollina AU - Ray Chang AU - Dominic Peralta AU - Samhita P. Banavar AU - Eliott Flaum AU - Hazel Soto-Montoya AU - Hongquan Li AU - Kyle Combes AU - Emma Pan AU - Khang Vu AU - Kelly Yen AU - James Dale AU - Patrick Kolbay AU - Simon Ellgas AU - Rebecca Konte AU - Rozhin Hajian AU - Grace Zhong AU - Noah Jacobs AU - Amit Jain AU - Filip Kober AU - Gerry Ayala AU - Quentin Allinne AU - Nicholas Cucinelli AU - Dave Kasper AU - Luca Borroni AU - Patrick Gerber AU - Ross Venook AU - Peter Baek AU - Nitin Arora AU - Philip Wagner AU - Roberto Miki AU - Jocelyne Kohn AU - David Kohn Bitran AU - John Pearson AU - Cristián Muñiz Herrera AU - Manu Prakash Y1 - 2020/01/01 UR - http://medrxiv.org/content/early/2020/04/29/2020.04.24.20078907.abstract N2 - Here we adapt and evaluate a full-face snorkel mask for use as personal protective equipment (PPE) for health care workers, who lack appropriate alternatives during the COVID-19 crisis in the spring of 2020. The design (referred to as Pneumask) consists of a custom snorkel-specific adapter that couples the snorkel-port of the mask to a rated filter (either a medical-grade ventilator inline filter or an industrial filter). This design has been tested for the sealing capability of the mask, filter performance, CO2 buildup and clinical usability. These tests found the Pneumask capable of forming a seal that exceeds the standards required for half-face respirators or N95 respirators. Filter testing indicates a range of options with varying performance depending on the quality of filter selected, but with typical filter performance exceeding or comparable to the N95 standard. CO2 buildup was found to be roughly equivalent to levels found in half-face elastomeric respirators in literature. Clinical usability tests indicate sufficient visibility and, while speaking is somewhat muffled, this can be addressed via amplification (Bluetooth voice relay to cell phone speakers through an app) in noisy environments. We present guidance on the assembly, usage (donning and doffing) and decontamination protocols. The benefit of the Pneumask as PPE is that it is reusable for longer periods than typical disposable N95 respirators, as the snorkel mask can withstand rigorous decontamination protocols (that are standard to regular elastomeric respirators). With the dire worldwide shortage of PPE for medical personnel, our conclusions on the performance and efficacy of Pneumask as an N95-alternative technology are cautiously optimistic.Key points Full-face snorkel masks are adapted for use as Personal Protective Equipment during the COVID-19 crisis, using a custom adapter that facilitates the attachment of inline medical-grade respiratory filters or NIOSH industrial respirator filters. This solution was designed as a reusable stopgap solution for healthcare workers to help address the short-term global N95 respirator shortage.Competing Interest StatementGerry Ayala (Wildhorn Outfitters), Quentin Allinne (Subea Decathlon), and Dave Kasper (iSnorkel Inc) have company affiliations with snorkel-mask manufacturers or distributors. They consulted on original designs of these masks, and in some cases to help with adapter design strategy. None of the scientific data included in this report, nor the conclusions of this report were written or substantially influenced by these co-authors. John Pearson, MD has a conflict of interest, as a stake holder in a for-profit entity focused on snorkel-based PPE. Patrick Kolbay is volunteering his time at this company. We certify that none of the other authors have any affiliations with or involvement in any organization or entity with any financial interest in the subject matter or materials discussed in this manuscript. None of the other authors (beyond what is listed above) have any affiliations with John Pearson's company.Funding StatementWe thank Schmidt Futures, Moore Foundation, Autodesk and CZ BioHub for financial support of the project.Author DeclarationsAll relevant ethical guidelines have been followed; any necessary IRB and/or ethics committee approvals have been obtained and details of the IRB/oversight body are included in the manuscript.YesAll necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesAll data is available in the manuscript and upon request from the authors. ER -