TY - JOUR T1 - Sonication of the Anterior Thalamus with MRI-Guided Low Intensity Focused Ultrasound Pulsation (LIFUP) Changes Pain Thresholds in Healthy Adults: A Double-Blind, Concurrent LIFUP/MRI Study JF - medRxiv DO - 10.1101/2020.04.08.20042853 SP - 2020.04.08.20042853 AU - Bashar W. Badran AU - Kevin Caulfield AU - Sasha Stomberg-Firestein AU - Philip Summers AU - Logan T. Dowdle AU - Matt Savoca AU - Xingbao Li AU - Christopher W. Austelle AU - E. Baron Short AU - Jeffrey J. Borckardt AU - Norman Spivak AU - Alexander Bystritsky AU - Mark S. George Y1 - 2020/01/01 UR - http://medrxiv.org/content/early/2020/04/10/2020.04.08.20042853.abstract N2 - Background Low Intensity Focused Ultrasound Pulsation (LIFUP) is a noninvasive brain stimulation method that may modulate deep brain structures using ultrasonic waves. Presently there are limited studies in humans rigorously assessing behavioral effects following LIFUP sonication of deep brain nuclei. As an initial test, we investigated whether sonication of the anterior thalamus, a central relay structure of nociception, would modulate thermal pain thresholds in healthy individuals.Methods We enrolled 19 healthy individuals in this three-visit, double-blind, randomized, sham-controlled, crossover trial. Participants attended a first MRI screening visit to acquire anatomical scans for LIFUP targeting. They then attended two identical experimental LIFUP/MRI visits (counterbalanced by condition) at least one-week apart. Within the MRI scanner, participants received two, 10-minute sessions of either active or sham LIFUP spread 10 minutes apart to the right anterior thalamus [Fundamental frequency:650khz, pulse repetition frequency: 10 HZ, Pulse Width: 5ms, Duty Cycle: 5%, Sonication Duration: 30s, Inter-Sonication Interval: 30 s, Number of Sonications: 10, ISPTA.3 719 mW/cm2]. Each 10-minute session was delivered in a block design (30s ON, 30s OFF). The primary outcome measure was quantitative sensory thresholding (QST), measuring sensory, pain, and tolerance thresholds to a thermal stimulus applied to the left forearm before and after LIFUP. Thermal stimuli were also applied in the scanner during certain blocks, either alone, or during LIFUP.Results Two 10-minute sessions of thalamic LIFUP produced a significant antinociceptive effect on pain thresholds. Temperature sensitivity increases were significantly attenuated (timeXcondition p=0.046) after active LIFUP (0.51 degree change) relative to sham stimulation (1.08 degrees). LIFUP also changed sensory and tolerance thresholds mathematically but this was not statistically significant with this sample. LIFUP delivered concurrently with thermal pain had no immediate behavioral effect.Conclusions Two, 10-minute sessions of anterior thalamic LIFUP has antinociceptive effects in healthy individuals. Future studies should optimize the parameter space and dose and perhaps investigate multi-session LIFUP interventions for pain disorders.Competing Interest StatementConflict of Interest Statement: AB is employed by BrainSonix, which manufactures the ultrasound device. He holds patents in this area. BWB owns minority stake in Bodhi NeuroTech Inc, which manufactures meditation enhancing devices and holds patents in this area. No other authors have any other conflicts.Clinical TrialClinicalTrials.Gov NCT# 04339972Funding StatementFunding for this study was provided by the Tiny Blue Dot Foundation (TBD).Author DeclarationsAll relevant ethical guidelines have been followed; any necessary IRB and/or ethics committee approvals have been obtained and details of the IRB/oversight body are included in the manuscript.YesAll necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesThe data that support the findings of this study are available from the corresponding author, BWB, upon reasonable request. ER -