RT Journal Article SR Electronic T1 Correction of Artifacts Induced by B0 Inhomogeneities in Breast MRI using Reduced Field-of-View Echo-Planar Imaging and Enhanced Reverse Polarity Gradient Method JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2020.03.31.20048900 DO 10.1101/2020.03.31.20048900 A1 Rodríguez-Soto, Ana E. A1 Park, Helen A1 Holland, Dominic A1 Keenan, Kathryn E. A1 Bartsch, Hauke A1 Kuperman, Joshua A1 Wallace, Anne M. A1 Hahn, Michael A1 Ojeda-Fournier, Haydee A1 Dale, Anders M. A1 Rakow-Penner, Rebecca YR 2020 UL http://medrxiv.org/content/early/2020/04/02/2020.03.31.20048900.abstract AB Purpose Diffusion weighted (DW) echo-planar imaging (EPI) is prone to geometric and intensity distortions due to B0 inhomogeneities. Pulse sequences that excite spins within a reduced field-of-view (FOV) in the phase encoding (PE) direction have been developed to decrease such distortions. In addition, use of the reverse polarity gradient (RPG) method, a retrospective approach to correct distortion artifacts, has been shown to improve the localization of tumor lesions. The purpose of this work was to evaluate the performance of reduced-FOV acquisition and RPG in decreasing distortion artifacts for breast imaging.Methods EPI data were acquired with full and reduced-FOV in a breast phantom and in a group of 170 women at 3T. The performance of RPG in correcting distortion artifacts in EPI data was evaluated using the mutual information (MI) metric between EPI and anatomical low-distortion images before and after distortion correction.Results RPG corrected distortions by 61% in full-FOV EPI and 48% in reduced-FOV EPI in a breast phantom. In patients, MI increased on average 13±8% and 8±6% for both full and reduced-FOV EPI data after distortion correction, respectively. The 95th percentile and maximum displacement between uncorrected and corrected full-FOV EPI datasets were 0.8±0.3cm and 1.9±0.3cm, and for reduced-FOV were 0.4±0.2cm and 1.3±0.3cm.Conclusion Minimal distortion was achieved with RPG applied to reduced-FOV EPI data. RPG improved distortions for full-FOV, but with more modest improvements and limited correction near the nipple.Competing Interest StatementDr. Dale reports that he was a Founder of and holds equity in CorTechs Labs, Inc., and serves on its Scientific Advisory Board. He is a member of the Scientific Advisory Board of Human Longevity, Inc. He receives funding through research grants from GE Healthcare to UCSD. Dr. Dale also reports that he holds a Professor II position for scientific collaboration with Oslo University Hospital. Dr. Rakow-Penner has received funding through research grants from GE Healthcare to UCSD.Funding StatementGE Healthcare, RSNA Research Resident Grant, and California Breast Cancer Research Program Early Career Award.Author DeclarationsAll relevant ethical guidelines have been followed; any necessary IRB and/or ethics committee approvals have been obtained and details of the IRB/oversight body are included in the manuscript.YesAll necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesData may be shared upon request.