%0 Journal Article %A Ge Chen %A Jiarong Xie %A Guangli Dai %A Peijun Zheng %A Xiaqing Hu %A Hongpeng Lu %A Lei Xu %A Xueqin Chen %A Xiaomin Chen %T Validity of Wrist and Forehead Temperature in Temperature Screening in the General Population During the Outbreak of 2019 Novel Coronavirus: a prospective real-world study %D 2020 %R 10.1101/2020.03.02.20030148 %J medRxiv %P 2020.03.02.20030148 %X Aims Temperature screening is important in the population during the outbreak of 2019 Novel Coronavirus (COVID-19). This study aimed to compare the accuracy and precision of wrist and forehead temperature with tympanic temperature under different circumstances.Methods We performed a prospective observational study in a real-life population. We consecutively collected wrist and forehead temperatures in Celsius (°C) using a non-contact infrared thermometer (NCIT). We also measured the tympanic temperature using a tympanic thermometers (IRTT) and defined fever as a tympanic temperature ≥37.3°C.Results We enrolled a total of 528 participants including 261 indoor and 267 outdoor participants. We divided outdoor participants into four types according to their means of transportation to the hospital as walk, bicycle, electric vehicle, car, and inside the car. Under different circumstance, the mean difference ranged from −1.72 to −0.56°C in different groups for the forehead measurements, and −0.96 to −0.61°C for the wrist measurements. Both measurements had high fever screening abilities in inpatients (wrist: AUC 0.790; 95% CI: 0.725-0.854, P <0.001; forehead: AUC 0.816; 95% CI: 0.757-0.876, P <0.001). The cut-off value of wrist measurement for detecting tympanic temperature ≥37.3°C was 36.2°C with a 86.4% sensitivity and a 67.0% specificity, and the best threshold of forehead measurement was also 36.2°C with a 93.2% sensitivity and a 60.0% specificity.Conclusions Wrist measurement is more stable than forehead measurement under different circumstance. Both measurements have great fever screening abilities for indoor patients. The cut-off value of both measurements was 36.2°C. (ClinicalTrials.gov number: NCT04274621)Competing Interest StatementThe authors have declared no competing interest.Clinical TrialNCT04274621Funding StatementNone.Author DeclarationsAll relevant ethical guidelines have been followed; any necessary IRB and/or ethics committee approvals have been obtained and details of the IRB/oversight body are included in the manuscript.YesAll necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesThe data used to support the findings of this study are available from the corresponding author (Xiaoming Chen).2019-nCoV2019 Novel CoronavirusNCITNon-contact infrared thermometerIRTTinfrared tympanic thermometersROCreceiver–operator characteristic %U https://www.medrxiv.org/content/medrxiv/early/2020/03/06/2020.03.02.20030148.full.pdf