TY - JOUR T1 - Estimation of Quasi-Continuous Blood Pressure based on Harmonic Phase-Shifts in Signals using Non-Invasive Photoplethysmographic Measurements JF - medRxiv DO - 10.1101/2019.12.19.19015321 SP - 2019.12.19.19015321 AU - Fabian Kern AU - Stefan Bernhard Y1 - 2019/01/01 UR - http://medrxiv.org/content/early/2019/12/21/2019.12.19.19015321.abstract N2 - According to the guidelines of the European Society of Hypertension International Protocol revision 2010, the requirements for long time blood pressure measurement (BPM) are: simple handling, robustness against movements, accuracy of better than ± 5 mmHg, and, above all, that the patient’s motion should not be restricted during measurement. These requirements are in particular important for a reliable interpretation of the blood pressure (BP) of hypertensive patients, because such a diagnosis will usually be confirmed by long-term measurement. Moreover, to be able to correlate the patient’s BP with his normal daily activity, non-obstructive non-invasive methods are desired to reduce the patient’s load.The main concern of this paper is to present a novel method for estimating non-invasive continuous blood pressure (CBP) from a single photoplethysmography (PPG) signal. In contrast to the pulse transit time (PTT) method, our approach is based on the assumption that the phase-velocities of the fundamental and higher harmonics depend on the (non-linear) elastic properties of the arteries. Consequently, phase velocity varies as a function of a vessel’s instantaneous dilation and can be effectively utilised for CBP estimation.In addition to its numerous advantages for a simplified measurement setup, we could show that the method achieves a high degree of correlation for a reliable BP estimation from PPG data. Comparison with state-of-the-art PTT methods was carried out using a dataset from the PhysioBank Database comprising a reference invasive blood pressure (IBP) signal measured at the radial artery, a PPG signal measured at the fingertip and a standard ECG signal.The correlation values obtained from the long-time estimation of the systolic blood pressure (SBP) were as high as r = 0.8945, while the value for the diastolic blood pressure (DBP) was found to be r = 0.9082 and the correlation of the mean blood pressure (MBP) was r = 0.9322. These results were achieved by analysing the dataset in a beat-to-beat manner and regarding several post-processing procedures like coherent averaging (CA) and zero padding with quasi-continuous frequency domain estimation and artificially refined frequency resolution.Competing Interest StatementThe authors have declared no competing interest.Funding StatementState of Baden Wuerttemberg, Germany, Ministry of Science, Research and ArtsAuthor DeclarationsAll relevant ethical guidelines have been followed; any necessary IRB and/or ethics committee approvals have been obtained and details of the IRB/oversight body are included in the manuscript.YesAll necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesAll data is available free on UCI Machine Learning Repository of the University of California, Irvine, which is part of the “PhysioNet” data basehttps://archive.ics.uci.edu/ml/index.php ER -