TY - JOUR T1 - Characteristics of Cardiac Memory in Patients with Implanted Cardioverter Defibrillator: the CAMI study JF - medRxiv DO - 10.1101/19005181 SP - 19005181 AU - Kazi T. Haq AU - Jian Cao AU - Larisa G. Tereshchenko Y1 - 2019/01/01 UR - http://medrxiv.org/content/early/2019/08/30/19005181.abstract N2 - Background Cardiac memory (CM) was known as a repolarization phenotype, an adaptive response of the heart on abnormal ventricular activation. The goal of this study was to determine factors associated with CM in patients receiving implantable cardioverter-defibrillators (ICD). We hypothesized that preexisted cardiac remodeling is associated with CM.Methods Patients with structural heart disease (n=20; mean age 72.6±11.6 y; 80% male; mean left ventricular ejection fraction (LVEF) 31.7±7.6%; history of myocardial infarction (MI) in 75%, ventricular tachycardia (VT) in 85%) and preserved atrioventricular (AV) conduction received primary (80%) or secondary (20%) prevention dual-chamber ICD. Standard 12-lead ECG was recorded in AAI and DDD mode, immediately after ICD implant and after 7 days of right ventricular (RV) pacing in DDD mode with short AV delay. Direction (azimuth and elevation) and magnitude of spatial QRS, T, and ventricular gradient (SVG) vectors were measured immediately after implant and after 7 days of RV pacing. CM was quantified as the degree of alignment between QRSDDD-7 and TAAI-7 vectors (QRSDDD-7-TAAI-7 angle). Circular statistics and mixed models with a random slope and intercept were adjusted for days 1-7 change in cardiac activation, LVEF, known risk factors, and use of medications known to affect CM.Results QRSDDD-7-TAAI-7 angle strongly correlated (circular r = −0.972; P<0.0001) with TAAI-7-TDDD-7 angle. Baseline TDDD-1 azimuth correlated with QRSAAI-7-QRSDDD-7 angle (circular r = 0.604; P<0.001). In the mixed models, history of MI (−180°(95%CI −320° to −40°); P=0.011) and female sex (−162°(95%CI −268° to −55°); P=0.003) counteracted CM-T azimuth changes (+132°(95%CI 80°-184°); P<0.0001). History of VT (+27(95%CI 4-46) mV*ms; P=0.007) amplified CM-T area increase (+15(95%CI 6 – 24) mV*ms; P<0.0001).Conclusions Existing cardiac remodeling due to MI and VT significantly affects the degree of CM in response to RV pacing. Women develop less CM than men. Activation memory manifests as a smaller angle between QRS vectors of normal and abnormal activation.Competing Interest StatementThe CAMI study was sponsored by Medtronic, Inc.Clinical Trialthis is not a clinical trialFunding StatementThis research was supported in part by the National Institute of Health HL118277 (LGT). The CAMI study was sponsored by Medtronic, Inc. Author DeclarationsAll relevant ethical guidelines have been followed and any necessary IRB and/or ethics committee approvals have been obtained.YesAll necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesAny clinical trials involved have been registered with an ICMJE-approved registry such as ClinicalTrials.gov and the trial ID is included in the manuscript.Not ApplicableI have followed all appropriate research reporting guidelines and uploaded the relevant Equator, ICMJE or other checklist(s) as supplementary files, if applicable.Not ApplicableThe software code for the electrocardiogram and vectorcardiogram data analysis is provided as open-source. https://github.com/Tereshchenkolab/cardiacmemory https://github.com/Tereshchenkolab/Origin https://physionet.org/physiotools/geh/ ER -